Rinnai RIB2310MN, Sapphire RIB2310MN/A, RIB2310ML, Sapphire RIB2310ML/A, RIB2311MN/A Operation & Installation Manual

...
This appliance shall be installed in accordance with:




All Rinnai gas products
are A.G.A. certified.
SAPPHIRE



Rinnai Australia i Sapphire Operation & Installation Manual
Congratulations on the purchase of your Rinnai Sapphire gas log flamefire.
We trust you will have many years of comfort and enjoyment from your appliance.
BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE
REQUIREMENTS, FEATURES AND OPERATION OF YOUR NEW APPLIANCE.
Rinnai Australia ii Sapphire Operation & Installation Manual
BEFORE YOU START .......................................................................................................................................... 1
INSTALLATION REQUIREMENTS..................................................................................................................... 1
CERTIFICATION................................................................................................................................................. 1
CARTON CONTENTS / ITEM CHECKLIST........................................................................................................ 1
INSTALLATION RECORD.......................... ... .... ... ... ... ... .... .......................................... ... ... ... .... ... ......................... 3
SAFETY................................................................................................................................................................. 4
SAFETY DEVICES.............................................................................................................................................. 6
ABOUT YOUR HEATER ....................................................................................................................................... 7
GENERAL DESCRIPTION.................................................................................................................................. 7
DESIGN FEATURES.................... ... .... ... ... ... .... ... .......................................... ... ... ... .... ... ...................................... 8
CONTROL PANEL OPERATION................................... .... ... ... ... .... .......................................... ... ... ... ................... 9
TO TURN YOUR HEATER ON ........................................................................................................................... 9
FLAME HEIGHT & FAN SPEED SETTINGS ...................................................................................................... 9
TO TURN YOUR HEATER OFF ......................................................................................................................... 9
INTERRUPTION TO ELECTRICITY OR GAS SUPPLY DURING OPERATION................................................ 9
RESTART PROCEDURE AFTER INTERRUPTION TO ELECTRICITY SUPPLY ............................................. 9
RESTART PROCEDURE AFTER INTERRUPTION TO GAS SUPPLY ............................................................. 9
REMOTE / THERMOSTATIC CONTROLLED OPERATION.............................................................................. 10
REMOTE CONTROLLER - BATTERY INSTALLATION ................................................................................... 10
REMOTE CONTROLLER - SYNCHRONISATION. .......................................................................................... 11
REMOTE CONTROLLER - MANUAL OPERATION ......................................................................................... 11
REMOTE CONTROLLER - AUTOMATIC OPERATION................................................................................... 12
WIRELESS CONTROLLER / THERMOSTAT................................................................................................... 13
TO TURN YOUR HEATER ON WITH REMOTE / THERMOSTATIC CONTROL............................................. 15
MODES OF OPERATION ................................................................................................................................. 15
PROGRAMMING OF PROGRAM MODES....................................................................................................... 17
CARE AND MAINTENANCE............................................................................................................................... 19
SERVICE........................................................................................................................................................... 19
TROUBLE SHOOTING ..................................................................................................................................... 19
TROUBLE SHOOTING CHECKLIST ................................................................................................................ 20
ABNORMAL FLAME PATTERN........................................................................................................................ 20
TABLE OF CONTENTS - INSTALLATION......................................................................................................... 22
CONTACT INFORMATION ................................................................................................................................. 53
TABLE OF CONTENTS - OPERATION
Rinnai Australia 1 Sapphire Operation & Installation Manual
BEFORE YOU START
INSTALLATION REQUIREMENTS
This heater must be installed by an authorised person. The installation must conform to local regulations. The installation must also comply with the instructions supplied by Rinnai. Service and removal must be carried out by an author i sed pe rso n .
CERTIFICATION
The Rinnai Sapphire
®
has been certified by the Australian Gas Association. The AGA Certification Number is shown on the appliance dataplate. No parts or functions should be modified or permanently removed from the heater. Please keep these instructions in a safe place for future reference.
CARTON CONTENTS / ITEM CHECKLIST
The components for Sapphire heater are supplied in separate cartons, the following tables list which components are in each carton. Ensure that the components listed for the installation meth od being installed are present be fore proceeding with the installation.
The Engine and Fascia are packed into two separate cartons and are required for all installation types. Masonry installations may require a flexiliner flue to be installed, refer to “MASONRY FLUE INSTALLATION” on page 30 for details.
Component Descriptions
Carton Contents
Engine Fascia
Engine and Fascia - Masonry Installations (x2 Cartons)
Rinnai Sapphire Engine. Fascia. Glass dress guard. Inner metal surround. Artificial log set / burn media, Satchel burner granules (shipped inside engine). Semi rigid stainless steel gas pipe with 5/8” connections (x1). ½” BSP - 5/8” UNF flared brass adaptors (x1). ½” BSP Flared nut (x1). 5/8” UNF Plug (x1). Fascia attachment screws (2 x 8g black, pre-fitted in tabs of heater engine). Adhesive backed foam sealing strip. Operation and Installation manual.
IMPORTANT
12
6
11
7
8
9
1
4
5
2
3
5
5
A
10
10
4
A
1
234
567
8910
11
12
Rinnai Australia 2 Sapphire Operation & Installation Manual
BEFORE YOU START
Component Descriptions
Carton Contents
Engine
Fascia
Zero
Clearance
Box
Console
Plinth
Remote
Thermostat
Spigot
Adaptor
Zero Clearance - Inbuilt Installation (x4 Cartons)
See Engine and Fascia (Masonry Installations) contents on previous page. Two piece Spigot Adapter Top Half and Bottom Half. Spigot guide panel. Spigot guide rails (x2). Zero Clearance - Top panel. Zero Clearance - Rear panel. Zero Clearance - Left & Right side panels. Base panel. Packet assembly screws (x27), grommets (x2) and rivets (x2).
Console Installation - Freestanding Installation (x4 Cartons)
See Engine and Fascia (Masonry Installations) contents on previous page. Two piece Spigot Adapter Top Half and Bottom Half. Console Installation - Top panel. Console Installation - Left side panel. Console Installation - Right side panel. Console Installation - Rear panel. Console Installation - Pillar. Packet assembly screws 35 x 8g and 7 x M5.
Plinth Installation - Freestanding Installation (x4 Cartons)
See Engine and Fascia (Masonry Installations) contents on previous page. Two piece Spigot Adapter Top Half and Bottom Half. Plinth Installation - Top panel. Plinth Installation - Left side panel. Plinth Installation - Right side panel. Plinth Installation - Rear panel. Plinth Installation - Pillar assembly. Plinth Installation - Base panel. Packet assembly screws 35 x 8g (only 29 needed for installation) and 7 x M5.
Optional Wireless Remote / Thermostatic Control (x1 Carton)
Wireless remote/thermostatic control with wall mount. AA batteries (x2). Operating Instruction.
Optional Two Piece Spigot Adapter (x1 Carton)
Two piece Spigot Adapter Top Half, Bottom Half and assembly screws (x4)
A
3
7
2
1a+b
8
5
6
4
B
6
C
1a+b
A
3
2
7
4
5
6
1a+b
1a+b
D
A
3
2
4
5
6
7
8
1
E
2
3
F
B
A
1
a
b
2345678CA
1
a
b
2
3
456
7
D
A
1
a
b
234
567
8
E
123
F
1
a
b
Rinnai Australia 3 Sapphire Operation & Installation Manual
INSTALLATION RECORD
INSTALLERS / GAS FITTERS DETAILS
Installers Name: ____________________________________________________________________ Company Name: ____________________________________________________________________ Company Address: ____________________________________________________________________
____________________________________________________________________ ____________________________________________________________________
Company Contact Details Telephone: ____________________________________________________________________ Mobile Phone: ____________________________________________________________________
Certificate of Compliance / Certification Number: _____________________________________________
Authorised Persons - Licence Number: _____________________________________________________ Installers Signature: ____________________________________________________________________ Installation Date: ____________________________________________________________________
APPLIANCE DETAILS
Model Number: ____________________________________________________________________ Serial Number: ____________________________________________________________________ Installation Address: ____________________________________________________________________
____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________
THIS APPLIANCE MUST BE INSTALLED, SERVICED
AND REPAIRED BY AN AUTHORISED PERSON.
Rinnai Australia 4 Sapphire Operation & Installation Manual
SAFETY
• Failure to comply with these instructions could result in a fire or explosion, which could cause serious injury, death or property damage.
• Improper installation, adjustments, service or maintenance can cause serious injury, death or property damage. Such work must be performed by an authorised person.
• The appliance must be installed in accordance with the local gas and electrical authority regulations.
• Flue terminal must always vent directly to outdoors.
• DO NOT extend the flue vertically or horizontally in ways other than prescribed in the appliance manufacturers’ installation instructions.
• For information on gas consumption, see data plate on the appliance.
• This appliance must not be instal led whe re cu rtains or other combustible materials could come into contact with it. In some cases curtains may need restraining.
• WARNING: This heater MUST NOT be used if either of the glass panels are damaged.
• When considering installation ensure minimum clearances as follows are adhered to:
• Heat radiating from the front of this heat er may over time affect the appe arance of some materials used for flooring such as carpet, vinyl, cork or timber. This effect may be amplified if the air in the room contains cooking vapours or cigarette smoke. To avoid this possibility, it is recommended that a mat or similar protective sheet be placed in front of the appliance, extending at least 750 mm in front of the glass guard.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experienc e and knowledge, unless they have been give n supervision or instruction concerning use of the appliance by a person responsible for their safety.
• The appliance is not intended for use by young children or infirm persons without supervision.
• Young Children must be supervised when in the vicinity of this heater while it is in operation.
• The Glass Dress Guard MUST be fitted to this appliance to reduce the risk injury from serious burns and no part of it should be permanently removed.
• For protection of young children or the infirm a secondary guard is required.
• If the supply cord is damaged or requires replacing, it must be replaced by the manufacturer or the manufacturer's agent or similarly qualified person in order to avoid a hazard.
• The heater must not be located immediately below a power socket outlet.
• DO NOT connect to an LPG Gas cylinder indoors.
• A dedicated 240 V earthed 10 Amp power point must be used with this appliance.
• DO NOT modify this appliance. Modifying from original specifications may create a dangerous situation and will void your warranty.
• Only the flue components specified by Rinnai must be used.
• Unpack the heater and check for damage. DO NOT INSTALL A DAMAGED HEAT ER. If t he hea te r is damaged, contact your supplier for advice.
• Before installing the heater, check the label for the correct gas type (refer rating plate, inside the appliance).
• Refer to local gas authority for confirmation of the gas type if you are in doubt.
WARNING
75mm
750mm
1000mm
400mm
400mm
10mm
10mm
750mm
1000mm
400mm
400mm
INBUILT MODELS FREE-STANDING MODELS
75mm
Rinnai Australia 5 Sapphire Operation & Installation Manual
SAFETY
The appliance is not intended for use by young children or infirm persons without supervision.Young children should always be supervised to ensure that they DO NOT play with the appliance.
DO NOT sit or lean against the heater. DO NOT allow children or elderly persons to sleep in the warm air discharge from the heater.
DO NOT post or allow children to post articles into the louvres of the heater. DO NOT cover or place articles on this heater. DO NOT place articles in front of the louvres.
DO NOT operate / install this heater in area s where painting is taking place, or in places such as hairdressing
salons, where there may be fluff and dust, and where aerosols are used.
DO NOT place articles on or against this appliance. DO NOT use or store flammable materials near this appliance. Keep flammable materials away from heater. Combustible materials MUST NOT be placed where the heater could ignite them. DO NOT spray aerosols in the vicinity of this appliance while it is in operation. Most aerosols contain flammable
substances which can be a heater hazard if used near this heater when it is in use.
Rinnai Australia 6 Sapphire Operation & Installation Manual
SAFETY
A dedicated 240V earthed 10 Amp power point must be used with this appliance. DO NOT use power boards or double adaptors to operate this appliance. Th e heater MUST NOT be loca ted below
a power socket-outlet. DO NOT place containers of liquid on top of the heater. Water spillage can cause extensive damage to the
appliance and create an electrocution hazard.
DO NOT place articles on or against this appliance. DO NOT CONNECT TO AN LPG GAS CYLINDER INDOORS.
Turn the heater ‘OFF’ after use.
DO NOT unplug the heater while it is in operation or while the fan is still cycling. DO NOT remove the Glass Dress Guard. The dress guard is fitted to this appliance to reduce the risk of fire or
injury from burns and no part of it should be permanently removed. For protection of children or the infirm, a secondary guard is recommended.
Heat emanating from the front of the appliance may over time affect the appearance of some materials used for flooring such as carpet, vinyl, cork or timber. This affect may be amplified if the air in the room contains cooking vapours or cigarette smoke. To avoid this possibility, it is recommended that a mat be placed in front of the appliance, extending at least 750 mm in front of the heater.
When the heater is operated for the first time or after long period s of non use a slight odou r may be emitte d, this is normal. However if odours persist switch ‘OFF’ the appliance and contact Rinnai.
SAFETY DEVICES
Over Heat Switches: When the heater gets too hot during operation (for example when air outlet louvres are
blocked) these devices turn the gas off automatically and allow the heater to restart when cooled down.
Electrical Fuse: The electrical circuits are protected by a fuse. Flame Failure Sensing System: This device automatically cuts off the gas supply to the heater in the event of a
flame failure. Power Failure: In the event of a power failure or power cut, the gas valves will automatically close.
750mm
Rinnai Australia 7 Sapphire Operation & Installation Manual
ABOUT YOUR HEATER
GENERAL DESCRIPTION
Your Sapphire is a burning log effect, gas space heating appliance with natural draft combustion system, intended for use with Natural Gas, Propane and ULPG. The Burning lo g effect is achieved using one single main burner with strategically placed, 'life like', imitation logs and granules. Temperature control is achieved by pressing the up or down marked arrows on the manual control switch o r via a cordless wall mounted remote control th ermostat / timer.
This heater has an electronic ignition with intermittent pilot. The pilot is only on when the heater is in opera tion. Burner, logs and granules are contained in a glass fronted, sealed burner box. Combustion air is drawn from the room. Combustion product is exhausted via the flue discharge vent when
installed in a masonry chimney or when installed in a zero clearance box or as a stand alone unit through a 100mmØ x 150mmØ twin skinned flue to the outside of the house.
This appliance is modular and primarily consists of an 'Engine' that is utilized in any of the 3 configuration types as listed below.
1. Fireplace / Masonry installation - Engine:
The appliance is directly mounted into an existing masonry fire place or a non-co mbustible/masonry en closure that has a chimney. When installed correctly the appliance is a flush to wall mount.
2. Zero Clearance installation:
The Appliance is fitted within a sheet metal Zero Clearance Box Assembly that has been installed in to a wall or other suitable structure. Materials need not be non-combustible. When installed correctly the appliance is a flush to wall mount.
3. Freestanding Plinth or Console appliance:
The appliance is housed in a decorative fabricated sheet metal box that is inte nded to be freestanding and not inbuilt.
MASONRY
PLINTH
ZERO CLEARANCE
CONSOLE
Rinnai Australia 8 Sapphire Operation & Installation Manual
DESIGN FEATURES
Rinnai Sapphire Heater Push button control panel
ON / OFF (Standby) button Power / operation indicator Flame Up button
Flame Down button Glass dress guard Flame window - artificial log set and burn media Warm air discharge vent Return air vent Alternative power cable outlet location on front panel can be left or right handed Optional Radio Frequency (RF) combination remote / thermostatic control with wall mount.
1
7 7
3
6
4
8
a
b
c
d
2
5
1
2abcd
3
4
5
6
7
8
ABOUT YOUR HEATER
Rinnai Australia 9 Sapphire Operation & Installation Manual
CONTROL PANEL OPERATION
TO TURN YOUR HEATER ON
The 'Push Button Control Panel' is located at the top left edge of the heater.
Step 1. Press ‘ON’/‘OFF’ button once. The
electronic ignition sparker will be able to be heard.
Step 2. The electronic ignition stops when the
pilot flame has been established, the main burner then ignites off the pilot and is automatically preset to Stage 7 ­High Flame. The blue LED Power
Indicator, will be constantly illuminated indicating heater is in operation.
Step 3. Flame height may be adjusted after 1
minute of operation. To change the burner and fan settings press to increase flame height and to decrease flame height.
FLAME HEIGHT & FAN SPEED SETTINGS
TO TURN YOUR HEATER OFF
To turn the heater 'OFF' press the 'ON'/'OFF' Button once. The blue LED Power Indicator , will extinguish to indicate that the appliance has returned to the in OFF condition.
INTERRUPTION TO ELECTRICITY OR GAS SUPPLY DURING OPERATION
Interruption to the power or gas supply will turn your heater off. Restart will be required This is a safety feature designed to ensure that un-attended starts do not occur.
RESTART PROCEDURE AFTER INTERRUPTION TO ELECTRICITY SUPPLY
To restart your heater once power has been restored follow the steps for “TO TURN YOUR HEATER ON” above.
RESTART PROCEDURE AFTER INTERRUPTION TO GAS SUPPLY
The instant gas supply is interrupted the heater will attempt re-ignition for a period of 60 seconds. If the heater has not re-lit after 60 seconds the gas control will go to 'Gas Lock-out'. The convection fan will remain
on for 4 minutes to cool the appliance. To restart your heater once gas has been restored:
Step 1. Ensure gas supply has been re-established to heater. Step 2. To re-set the gas control turn 'OFF' the heater by pressing 'ON/OFF' button once. Step 3. In rapid succession Press button , 3 times. (Turn 'ON', then 'OFF', then 'ON' again), within a 5 second
period.
BEFORE PROCEEDING ENSURE THE GAS AND ELECTRICITY ARE TURNED ON. When the heater is in the OFF condition (the power supply connected and switched ON but the
heater turned OFF) the Power Indicator will be extinguished, this is normal.
The relationship between the flame height and fan speed are preset and can not be independently adjusted.
FLAME HEIGHT1234567
FAN SPEED HIGH LOW LOW LOW HIGH HIGH HIGH
When the heater is in the OFF/STANDBY condition (power supply c onnected and switched ON) the blue LED Power Indicator will be extinguished. This is normal.
NOTE
a
b
c
d
abc
d
NOTE
NOTE
a
b
a
a
Rinnai Australia 10 Sapphire Operation & Installation Manual
REMOTE / THERMOSTATIC CONTROLLED OPERATION
For further enhanced comfort and conv enience the Sapphire heater can be both remotely and thermostatically controlled through the use of a wireless wall mountable controller / thermostat.
The wireless controller / thermostat is an optional extra available through your Rinnai stockist.
DISPLAY LAYOUT & FEATURES
BUTTON LAYOUT & FEATURES
REMOTE CONTROLLER - BATTERY INSTALLATION
Carefully remove the battery compartment cover panel from the rear of your controller hand-set and insert the two AA batteries supplied ensuring that '+' and '-' polarity is correct. After installing the batteries your remote control will display an 'Initial Set-up Screen' with the current room temperature in °C, a default time setting of and the default day of the week set to ‘MO’ - Monday.
Time of day with ‘AM’ or ‘PM’ display
Displays time of the day in hours and minutes, ‘AM’ or ‘PM’. The time is displayed when the thermostat is ‘ON’ or ‘OFF’.
Day of the week Displays the current day of the week.
The day is displayed when the thermostat is ‘ON’ or ‘OFF’.
Current Room temperature display
Displays the current temperature. The temperature range is 7°C - 32°C.
Setting Temperature with ‘SET’ display
When the thermostat is ‘ON’, the programmed (set) temperature will be displayed.
Transmit indicator Indicates that the thermostat is transmitting to the receiver,
the symbol will appear on the LCD for 1 sec.
Battery Low indicator Indicates when the battery power is below an acceptable
level.
Automatic mode indicator Indicates if the thermostat is in automatic mode. Program mode indicator Indicates that the thermostat is in programming mode.
Manual mode indicator Indicates if the thermostat is in manual mode.
Setting ‘UP’ Button Increase hours, minutes, day or temperature.
‘OK’
Button Accepts the current function and advances to the next
function.
‘PWR’ (Power) Button Switches the thermostat ‘ON’ and ‘OFF’. To turn ‘ON’ press
and release the ‘PWR’ and ‘OK’ Buttons at the same time this will turn the thermostat ‘ON’ to the most recently programmed working mode.
‘A/M’ Button Toggles between automatic, manual and flame mode. ‘T’ (Time) Button Initiates time and day of the week pr ogramming (must press
and hold for 2 or more seconds when the thermostat is ‘OFF’).
Setting ‘DOWN’ Button Decrease hours, minutes, day or temperature. ‘P’ (Program) Button Initiates the programming mode (must press and hold for 2 or
more seconds when the thermostat is ‘OFF’).
Flame Indicator Indicates the flame setting.
The Flame symbol graphically indicates which of the 7 graduated settings between Low and High flame when the burner is on.
In AUTO or MANUAL temperature mode, if the burner is OFF due to room temperature being reached the symbol will modulate UP and DOWN. This is to indicate that the unit is still ON even though there are no flames visible in the appliance.
When batteries are changed all settings other than synchronisation are lost and the controller will revert back to the 'Initial set -up screen'.
A/M PWRTP
DOWN
UP
OK
1
2
6
9
8
5
7
17
4
3
1
2
3
4
5
6
7
8
9
A/M PWRTP
DOWN
UP
OK
10
11
14 15
16
13 12
10
11
12
13
14
15
16
17
NOTE
Rinnai Australia 11 Sapphire Operation & Installation Manual
REMOTE / THERMOSTATIC CONTROLLED OPERATION
REMOTE CONTROLLER - SYNCHRONISATION.
Synchronisation of Controller & The Heater
Step 1).Turn the power off at the power point for a minimum of 30 seconds, synchronisation will not be
possible unless the minimum 30 seconds has been observed.
Step 2).Ensure the remote control is turned OFF , to turn OFF press and release the ‘PWR’ button once . Step 3). Turn the power ON at the power point, the blue power operation indicator on the push
button control panel will flash once. The controller can now be synchronised with the heater.
Step 4).On the controller in quick succession press the following sequence of buttons: ‘P’ > ‘T’ > ‘T’ > ‘UP’
The LCD display will show ‘L/C’ (Learn Code) for 2 seconds then return to the normal ‘OFF’ state display. The blue power operation indicator on the push button control panel will flash once to indicate that synchronisation has been accepted.
To restore factory default settings
With the thermostat ‘OFF’, press the following sequence of buttons ‘P’ > ‘T’ > ‘T’ > ‘DOWN’.
REMOTE CONTROLLER - MANUAL OPERATION Turning ‘ON’
Step 1). Press ‘ON’/‘OFF’ button of the Push Button Control Panel once the Power Indicator LED , will
illuminate blue.
Step 2). Press both the ‘OK’ and ‘PWR’ buttons on the controller at the same time. O perational control is now
transferred to the controller, the heater operation is then dependant on the controller mode as follows: In Manual Mode - Unless the set temperature is above that of the room temperature the heater will not
ignite and the power Indicator LED will turn red to indicate that the heater is in Controller Standby mode. Raising the set temperature above that of the room temperature will start heater operation and the Power Indicator LED , will change from red to blue.
Turning ‘OFF’
Step 1). To place heater into controller standby press the ‘PWR’ button once. The heater will go into ‘Standby’
mode and the power Indicator LED will turn red.
Step 2).To turn the heater 'OFF' press the 'ON'/'OFF' Button twice. The Power Indicator LED , will be
extinguished to indicate that the appliance has returned to the OFF condition.
Changing the temperature
The Sapphire has temperature increments of 1° which can be changed using the ‘UP’ and ‘DOWN’ buttons. The temperature control range is 7 - 32°C
Change between Celsius - °C and Fahrenheit - °F
The thermostat temperature display can be set to °C or °F. The default is °C. With the controller ‘OFF’, press the following sequence of buttons: ‘P’ > ‘T’ > ‘T’ ‘A/M’ to toggle between °C or °F.
Change between manual, automatic and flame modes
Press and release the ‘A/M’ button. The unit first lights the pilot and then after a short period switches to the ‘HIGH’ flame setting. To turn ‘OFF’ press and release the ‘PWR’ button once.
Before proceeding with synchronisation ensure that the gas and electricity are connected. Synchronisation must be carried out when a new controller has been purchased. Two controllers CAN NOT be used at the same time!
The heater will not respond the controller until synchronisation has been carried out.
Synchronisation MUST BE performed within 30 seconds of the power being turned ON, if more than 30 seconds has elapsed repeat steps 1 through 3.
NOTE
b
a
b
NOTE
b
a
b
b
b
b
a
b
Rinnai Australia 12 Sapphire Operation & Installation Manual
REMOTE / THERMOSTATIC CONTROLLED OPERATION
REMOTE CONTROLLER - AUTOMATIC OPERATION Setting the Current Time and Day of the Week
Step 1. With the controller ‘OFF’, press and hold the ‘T’ button for approximately 2 seconds. ‘TIME’
,
‘HOUR’ and ‘AM or PM’ will flash.
Step 2. To select the hour push the
‘UP’ button or ‘DOWN’ button until the desired hour is chosen, note
that AM or PM is chosen by cycling through the 12 hour range.
Step 3. Press the ‘OK’ button to enter the selected hour and AM or PM. ‘TIME’ + ‘MINUTES’ + ‘AM or PM’
will flash.
Step 4. To select the minutes push the ‘UP’ button or
‘DOWN’ button until the desired minutes are
chosen.
Step 5. Press the ‘OK’ button to enter selected minutes, One of the days SU, MO, TU, WE, TH, FR or SA
will flash.
Step 6. To select the hour push the
‘UP’ button or ‘DOWN’ button until the desired day is chosen.
Step 7. Press the ‘OK’ button to enter the selected day and to complete time and day setup.
To adjust time for Daylight Saving time
To adjust time or to adjust for daylight savings follow Steps 1 and 2 then press ‘OK’
button , three times to
keep the minutes and the current day.
If no buttons are pressed within 10 seconds the display will revert back to 'Initial Set-Up Screen' retaining the last entered setting.
When changing batteries all settings will be lost and the controller will revert back to the 'Initial setup screen'. Re-setting of time, date and programming will be necessary.
A/M PWRTP
DOWN
UP
OK
A/M PWR
OK
P
DOWN
UP
A/M PWRTP
DOWN
UP
OK
A/M PWR
OK
TP A/M PWRTP
DOWN
UP
OK
A/M PWRTP
DOWN
UP
STEP 1 STEP 2
14
15
10
STEP 3
11
14
NOTE
10
15
11
A/M PWRTP
DOWN
UP
OK
A/M P WRTP
DOWN
UP
A/M PWRTP
DOWN
UP
OK
A/M PWR
OK
TP A/M PWRTP
DOWN
UP
OK
A/M P WRTP
DOWN
UP
STEP 5
11
A/M PWRTP
DOWN
UP
OK
A/M PWR
OK
TP
STEP 4
15
10
STEP 6
15
10
STEP 7
11
10
15
11
10
15
11
11
NOTE
Rinnai Australia 13 Sapphire Operation & Installation Manual
REMOTE / THERMOSTATIC CONTROLLED OPERATION
WIRELESS CONTROLLER / THERMOSTAT
The wireless controller is designed to be wall mounted on a bracket, (bracket supplied with the controller), within 20m of the heater.
The controller houses the thermostat which senses room temperature and communicates back to the Sapphire heater via Radio Frequency.
The ideal position for the controller is:
• Away from possible drafts in the room.
• Away from direct sunlight.
• Suitable distance away from the heater (not exceeding 20 metres).
• Ideally 1.5 m from the floor (approximately at chest height).
Controller Specifications
Battery: 2 x AA batteries.
Battery Life: Approximately 12 months.
Dimensions: Height: 140 mm, Width: 80 mm, Depth: 20 mm.
Additional information about Remote Thermostat Control Buttons
Transmit Indicator
Indicates the thermostat is transmitting to the receiver, the symbol with appear on the LCD for 1 second.
Battery Indicator
This symbol will flash when batteries need replacing. The thermostat will remain functional for approximately 5 days before shutting ‘off’. Re-programming of the controller will be required after battery replacement.
Temperature Display
Displays current temperature. °C is the default but °F is available. The temperature range is 7°C - 32°C (45°F - 90°F).
Room Indicator or Set Indicator
When the thermostat is ‘ON’ the programmed (set) temperature and the room temperature will be displayed. When the Flame mode is ‘ON’ the Flame setting F7 to F1 will be displayed.
PWR + OK
Switches the thermostat ‘ON’ and ‘OFF’. If thermostat is ‘OFF’, pressing and releasing the ‘PWR’ + ‘OK’ button will turn the thermostat on to the most recently selected working mode.
T (Time)
Initiates the time and day of week programming, press and hold for 2 seconds.
UP, DOWN & OK
‘UP’ increase hours, minutes, day or temperature ‘OK’, accepts the current function and advances to the next function, ‘DOWN’, decrease hours, minutes, day or temperature.
P (Program)
Initiates the programming mode, press and hold for 2 seconds.
A/M PWRTP
DOWN
UP
OK
A/M TP
DOWN
UP
A/M PWRTP
DOWN
UP
OK
A/M PWR
OK
P
DOWN
UP
A/M PWRTP
DOWN
UP
OK
A/M PWRTP
A/M PWRTP
DOWN
UP
OK
A/M PWR
OK
T
DOWN
UP
Rinnai Australia 14 Sapphire Operation & Installation Manual
REMOTE / THERMOSTATIC CONTROLLED OPERATION
Additional information about Remote Thermostat Control Operation
Character Diagnostic Check. To check the display characters on the remote control turn the controller 'off' by pressing the 'PWR' button then press P - T - T - OK in rapid succession.
The remote will then commence automatically cycling through all the display characters, finally displaying the full screen as shown below.
This process takes approximately 20 seconds and does not affect any progr amming.
If any of the characters are not displayed contact your Rinnai sto ckist for a replacement controller. The Fan and Snowflake symbols displayed are not utilized in the ope ration of the Sapp hire heater.
A/M PWRTP
DOWN
UP
OK
A/M PWR
DOWN
UP
A/M PWRTP
DOWN
UP
OK
A/M
OK
TP
DOWN
UP
A/M PWRTP
DOWN
UP
OK
1 2 3
NOTE
Loading...