Rinnai RUR98e Specification

0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
0 25 50 75 100 125 150
kA3237
RUR98e (KBP3237WD)
Type of Appliance
Rinnai model number
Operation / Installation
Minimum/Maximum Gas Rate (Input)
Electrical Consumption
Amperage
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Energy Factor (EF)
Service Connections
Isolation & Pressure Relief Valves Included
Water Flow Control
Minimum/Maximum Water Supply Pressure
Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system with built in recirc pump, Energy Star Qualified
REU-KBP3237WD-US
Forced combustion; outdoor only; Certified for installation in Manufactured (Mobile) Homes
15,200 - 199,000 BTU/h (4.5-58.3 kW)
Appliance: AC 120 Volts - 60 Hz Temperature Controller: DC 12 Volts
Normal: 201 w Standby: 3 w Anti-frost protection: 210 w
Max: 8A Fuse: 10A
Direct electronic ignition
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM 1.5 l/min) Maximum flow rate: 9.8 GPM (37.1 l/min)
98° - 120° F (37°- 49°C) (factory default) Maximum temperature is selectable at 120° F (49°C) or at 140° F (60°C);
120° F (49°C) (factory default) or 140° F (60°C)
Natural or Propane (ensure unit matches gas type)
Natural Gas: 0.95 Propane: 0.95
Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT
Heavy duty forged brass isolation valves EXP E2, certified to NSF/ANSI 61­8 for potable water
Water flow sensor, electronic water control and by-pass control
50 - 150 PSI (345-1035 KPa) (60 - 80 PSI (414 - 552 KPa) or above is recommended for maximum flow)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
(37.9)
FLOW TABLE
Water Flow gpm (l/min)
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
(34.1)
(30.3)
(26.5)
(22.7)
(19.0)
(15.1)
(11.4)
(7.6)
(3.8)
0.0
25 (13.9) 50 (27.8) 75 (41.6) 100 (55.6) 125 (69.4) 150 (83.3)
delta T - Temperature Rise ºF (ºC)
© 2014 Rinnai Corporation
RUR98e-SP 9/2014
RUR98e (KBP3237WD)
Internal Recirculation Pump Control Built in Rinnai Circ-Logic™ : Recirculation program cycles internal pump
Controller
Maximum Recirculation Pipe Lengths
Controller Cable
Safety Devices
Clearances from Combustibles
* 24 inches (609.6mm) required for service
Clearances from Non-combustibles
* 24 inches (609.6mm) required for service
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
MC-195T-US (included)-Pump Timer Control MC-91-2US (optional)
Dedicated Return
-Total length includes both hot water supply lines and Dedicated Return line
Cross Over Mode
-Cross over mode requires use of included thermal by-pass valve
-Total length includes both hot water supply and cold water piping length from the tankless to thermal by-pass valve
400ft for 3/4” pipe diameter 100ft for 1/2” pipe diameter
Non-polarized two-core cable, minimum 22 AWG (Field Supplied)
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Top of heater - 6 inches (152.4mm) Front of heater - 6 inches *(152.4mm) Sides of heater - 2 inches (50.8mm)
Top of heater - 2 inches (50.8mm) Front of heater - 6 inches *(152.4mm) Sides of heater - 1/2 inches (12.7mm)
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Natural Gas: high fire 3.0” W.C. (7.2mbar) low fire 0.41” W.C. (1.0mbar) Propane Gas: high fire 3.5” W.C. (8.7mbar) low fire 0.46” W.C. (1.2mbar)
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Remaining flame (OHS) Thermal fuse Automatic frost protection
Back of heater - 0 inches Bottom of heater - 12 inches (304.8mm) From vent pipe - 0 inches
Back of heater - 0 inches Bottom of heater - 12 inches (304.8mm) From vent pipe - 0 inches
Limited Warranty
DIMENSIONS
0.6 (15) 2.0 (50)
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
WEIGHT: 72.8 lb (33 kg)
18.5 (470)
10.0 (253.8)
0.4 (10.1)
10.1 (257.5)
8.7 (222) A
0.6 (15)
25.7 (654)
28.4 (721.6)
DIMENSION Inches (mm)
A (GAS) 1.6 (40.2)
A (COLD) 2.0 (50.2)
A (HOT) 1.4 (36.4)
B 5.0 (127.2)
C 7.1 (179.7)
D 0.60 (15.3)
DIMENSION Inches (mm)
E 4.6 (116.8)
F 2.3 (57.7)
G 1.9 (47.8)
H 0.52 (13.3)
I 18.3 (466)
J 7.2 (181.5)
J