Rinnai RU90e Specification

RU90e (KB2934WD)
Type of Appliance
Rinnai model number
Operation / Installation
Minimum/Maximum Gas Rate (Input)
Electrical Consumption
Amperage
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified
REU-KB2934WD-US
Forced combustion; outdoor only; Certified for installation in Manufactured (Mobile) Homes
15,200 - 180,000 BTU/h (4.5-52.8 kW)
Appliance: AC 120 Volts - 60 Hz Temperature Controller: DC 12 Volts
Normal: 71 w Standby: 2 w Anti-frost protection: 168 w
Max with pump: 8A Max without pump: 4A Fuse: 10A
Direct electronic ignition
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM 1.5 l/min) Maximum flow rate: 9.0 GPM (29 l/min)
98° - 120° F (37°- 49°C) (factory default) Maximum temperature is selectable at 120° F (49°C) or at 140° F (60°C); 98° - 185° F (37°- 49°C) available with the MCC-91-2 controller for commercial and hydronic applications
120° F (49°C) (factory default) or 140° F (60°C)
Natural or Propane (ensure unit matches gas type)
Energy Factor (EF)
Service Connections
Isolation & Pressure Relief Valves Included
Water Flow Control
Minimum/Maximum Water Supply Pressure
Natural Gas: 0.96 Propane: 0.96
Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT
Heavy duty forged brass Webstone Isolator valves EXP E2, certified to NSF/ANSI 61-8 for potable water
Water flow sensor, electronic water control and by-pass control
50 - 150 PSI (345-1035 KPa) (60 - 80 PSI (414 - 552 KPa) or above is recommended for maximum flow)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
Water Flow gpm (l/min)
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
(37.9)
(34.1)
(30.3)
(26.5)
(22.7)
(19.0)
(15.1)
(11.4)
(7.6)
(3.8)
© 2014 Rinnai Corporation
0.0
25 (13.9) 50 (27.8) 75 (41.6) 100 (55.6) 125 (69.4) 150 (83.3) 0
delta T - Temperature Rise ºF (ºC)
RU90e-SP 9/2014
RU90e (KB2934WD)
External Recirculation Pump Control Built in Rinnai Circ-Logic™ : Recirculation program cycles external pump
Controller
Controller Cable
MC-91-2US (included) MC-195T-US (Optional) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
* 24 inches (609.6mm) required for service
Clearances from Non-combustibles
* 24 inches (609.6mm) required for service
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Limited Warranty
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Top of heater - 6 inches (152.4mm) Front of heater - 6 inches *(152.4mm) Sides of heater - 2 inches (50.8mm)
Top of heater - 2 inches (50.8mm) Front of heater - 6 inches *(152.4mm) Sides of heater - 1/2 inches (12.7mm)
Remaining flame (OHS) Thermal fuse Automatic frost protection
Back of heater - 0 inches Bottom of heater - 12 inches (304.8mm) From vent pipe - 0 inches
Back of heater - 0 inches Bottom of heater - 12 inches (304.8mm) From vent pipe - 0 inches
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Natural Gas: high fire 2.5” W.C. (6.2mbar) low fire 0.41” W.C. (1.02mbar) Propane Gas: high fire 2.8” W.C. (7.0mbar) low fire 0.46” W.C. (1.2mbar)
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
DIMENSIONS
18.5 (470)
10.0 (253.8)
0.6 (15) 2.0 (50)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
WEIGHT: 61.7 lb (28 kg)
0.4 (10.1) 0.6 (15)
10.1 (257.5)
8.7 (222)
C
B
D
E
DIM Inches (mm)
25.7 (654)
28.4 (721.6)
A
A (GAS) 1.6 (40.2)
A (COLD) 2.0 (50.2)
A (HOT) 1.6 (41.2)
A (CONDENSATE
OUTLET)
B 5.0 (127.2)
C 1.9 (47.8)
D 0.52 (13.3)
0.9 (22.4)
H
G
F
K
DIM Inches (mm)
E 2.2 (56.3)
F 2.3 (58.3)
G 5.0 (127.2)
H 2.0 (50)
I 3.0 (76)
J 7.1 (179)
K 18.3 (466)
J
I
Loading...