Assembly
(1) Make sure that the fan screw, fan, slot filter, rectifier, oil pack, etc, are correctly
fixed.
(2) Incorrect assembly may result in vibration or weaker air-flow.
Cautions
! Don’t touch the spout of negative ion on the front panel, the static electricity
sometimes may occur during the operation. (Only for RH-60ERI/EVI, RH71ERI/EVI, RH-90 ERI/EVI).
! When mounting the fan, fix the notch of fan to the motor axis pin and push them
together before tightening the fan screw.
! Fix the rectifier panel and the oil pack firmly to prevent dropping.
To prevent vibration and/or oil leak, tightened the screw and other parts properly.
! If the power cord of this equipment is damaged, replace it with a new cord.
SPECIFICATION
PART NAME
Mount the oil pack (left and right) just below the oil hole of the rectifier-panel.disposal
If the oil pack is not mounted just below this oil discharge hole, the oil will drop directly
to the gas cooker. (Fig. 1)
Mounting the oil pack
Oil Pack
Oil Disposal Hole
Fig. 1
1
6
Model
RH-60 ERI RH-60 EVI
RH-71 ERI RH-71 EVI
RH-90 ERI RH-90 EVI
Recycle / Ventilation
Dimension (WxDxH)mm
Weight (kg)
Motor / Fan
Air Volume ( M 3 / H )
Quietness ( dB (A) )
Power Consumption (W)
Lamp (W)
Air Duct dia (mm)
Smoke recovery (%)
Recycle
600x530x150 600x530x150
11.5 kg 11.5 kg
1Motor/1 Fan 1Motor/1 Fan 1Motor/1 Fan 1Motor/1 Fan 1Motor/1 Fan 1Motor/1 Fan
515 515 515 515 515 515
325 325 325 325 325 325
53.5
52.5
43
42
43
42
43
42
121 121 121 121 121 121
40 40 40 40 40 40
-
150 dia
150 dia
150 dia
98
75 75 75 75 75 75
98 98 98 98 98
Ventilation Ventilation Ventilation
Recycle
710x530x150 710x530x150 900x530x150 900x530x150
12.2 kg 12.2 kg
13.7 kg 13.7 kg
53.5
52.5
53.5
52.5
-
Recycle
-
MAX
MIN
MAX
MIN
220V~240V
MAX
MIN
RH-60 ER
RH-60 EV
RH-71 ER
RH-71 EV
RH-90 ER
RH-90 EV
Push Button Switch
Slot Filter
Rectifier Panel
Oil Pack
(Accessory)
Ionizer *
Fan
Fan Screw
Body
* Only for model:
RH-60 ERI/EVI
RH-71 ERI/EVI
RH-90 ERI/EVI