1. Determine a suitable location meeting the installation clearances shown in Figure 1 below.
Local building codes may restrict the clearances shown below. If you are unsure if the clearances
are acceptable in your area, consult with local building officials to verify prior to proceeding with installation.
Clearance to gas meter and electric meter shall be in accordance with local codes and the
requirements of the gas supplier or electric supplier.
Figure 1
All dimensions are from edge of box
12” (0.30 m) to window or door that may be opened
12” (0.30 m) to air inlets or vents
Clearances
8.5” (216 mm) to inside corner
The RGB-25U includes:
1 recess box 1 mounting bracket 1 mounting screw 4 lock nuts
32” (0.91 m) to a soffit or eve vent; or to a porch or deck
RECESS
BOX
4 washers (11/32) 1 locking bracket
Note: The clearance to
combustibles of the water heater/recess box assembly are zero inches to all surfaces of the recess box. A 24” clearance to combustibles and non-combustibles must be maintained from the front of the unit for servicing.
12” (0.30 m) to ground / snow line
2. Drill 4 holes spaced out along the length of each side of the recess box. The recess box is designed to be fitted between 2 studs and secured through these holes. (Figure 2)
3. Bottom Hole Access: Use the provided template to drill the appropriate holes for water, gas and electric access.
Side Hole Access: Identify the appropriate hole locations for water,
gas and electric. Watch for interference with the framing stud before drill the holes.
4. All recess box penetrations must be sealed to prevent moisture from entering the wall.
5. Apply a 3/8” bead of sealant along the back of the box flange.
Figure 3
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
1/2008 1 INST-RGB-25U
drill screw holes ­each side
Figure 2
mounting bracket and screw
washers
6. Position and secure the recess box to the building structure with suitable screws (galvanized or stainless steel) through the 8 holes in the sides. (Figure 2)
7. Follow the instruction for your water heater model. (The 2 screws are installed on the water heater.)
R/C85 or R70:
Install the bracket as shown with the higher keyhole on the left. The 2 washers (Figure
2) at the back of the recess box should remain.
FRONT
R/C85PLUS, R75LSe, R94LSe:
Install the bracket as shown with the lower keyhole on the left. Remove the 2 washers (Figure 2) at the back of the recess box.
8. Install the mounting screw half way through the bracket attached to the top of the recess box. (Figure 4)
9. Copy the water heater serial number and model number from the data plate located on the left hand side of the appliance onto the sticker which is on the inside of the recess box cover. You will need to know this information for any future warranty or service work.
10. Install the water heater in the recess box.
a. Lift the water heater into the recess box
and align the mounting screw with the left keyhole on the top mounting bracket. Tighten the screw
b. Attach 2 washers and 2 lock nuts to the
Left keyhole hangs on mounting screw
Model Number: _______________________
Serial Number: _______________________
Gas Type: ___________________________
studs at the bottom bracket.
FRONT
Figure 4
11. Remove the caps from the water heater and install the valve kit.
12. Install the pipes through the access holes made in step 3.
13. Connect gas, water and electric service to the water heater. Note: A waterproof electrical outlet can be fitted inside the enclosure.
14. Seal all recess box penetrations with sealant to prevent moisture from leaking out of the recess box.
15. Install the locking bracket with 2 washers and 2 lock nuts. (Figure 5)
16. On completion of work, check for gas and water leaks.
17. Install front cover by inserting the top end first.
2 INST-RGB-25U
Bottom bracket
Figure 5
DRAIN
HOT
Sealant Require
GAS
COLD
Locking bracket