Caution for the type of gas supplied
•
Ensure that the type of gas (gas group) supplied is same as the one
mentioned on the nameplate of the appliance.
•
Use of the appliance with incorrect gas type could result in carbon
monoxide poisoning due to incomplete combustion or burn injury due to
explosive ignition.
•
When you move to another house, ensure that the type of gas supplied
is same as the one mentioned on the nameplate once again.
0cm and above
•
If the distance of at least 20cm (sides),
15cm (rear) and 100cm (top) is unavailable
between the appliance and flammable wall,
installation of a heat insulating plate is
required shown in the illustrations on the
right.
•
Prevention of gas accident
Gas pipe work requires specialist qualifications
and expertise. Consult your dealer.
WARNING
Heat insulating plate
Material Thickness Caution
Steel plate
Stainless steel plate
0.6cm and above
0.6cm and above
Ensure a space at least 3cm and provide adequate
reinforcement to prevent harmful deformation.
Nameplate
•
About installation
•
Be sure to observe the precautions on installation to ensure compliance with the Fire Prevention
Ordinance. Insufficient clearance around the appliance may result in fire. Even if an inflammable wall
is covered with the object such as stainless steel plate, it is necessary to maintain the same distance
as required for combustible objects.
•
Do not refurbish the appliance’s surroundings
after the installation (such as enclosing the appliance,
installation of hanging shelf).
Such a refurbishment may not be compatible
with the installation
standards or cause imperfect combustion or fire.
•
If the wall around the appliance is flammable
(such as wooden wall), be sure to keep a
distance of at least 20cm, 15cm and 100cm
for sides, rear and top respectively.
For RGA-408A, RGA-410B, RGA-408C,
RGA-410C, an exhaust pipe with exhaust hood
needs to be installed above the appliance.
100cm and
above
20cm and
above
room and
below when
installing
exhaust
hood
15cm and
above
0cm and above
3cm and above0cm and above
3cm and above 3cm and above
0cm and above
0cm and above
- 2 -
•
Safety distance to combustible
object and fi re prevention measures
50cm and above
80cm and above
Leave a gap
<Nameplate>
(Model name)
(Manufactured date)
Confi rm the gas type
(Type of gas (gas group))
(Distributor)
Example) 00.08 (Manufactured on August 2008)
(Gas consumption)
(Serial No: YS)