Rinnai REU-VC2025FFU-US User Manual

V65i (VC2025FFU-US)
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
0 25 50 75 100 125 150
Type of Appliance
Rinnai Model Number
Operation / Installation
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Amperage
Hot Water Capacity
Temperature
Temperature (without remote)
Installation
Energy Factor
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
REU-VC2025FFU-US
Forced combustion; indoor only
10,300 - 150,000 BTU/h (3.0-44.0 kWh)
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts
Normal: 76 w Standby: 2 w Anti-frost protection: 120 w
Max: 4A Fuse: 10A
Direct electronic ignition
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)
98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° - 71° C) available with the MCC-91-2 controller for hydronic applications
120° F (49° C) (factory default) or 140° F (60° C)
Indoor only
Natural Gas: 0.82 Propane: 0.82
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device and fixed by-pass
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Water Flow gpm (l/min)
7.0 (26.5)
6.0 (22.7)
5.0 (19.0)
4.0 (15.1)
3.0 (11.4)
2.0 (7.6)
1.0 (3.8)
0.0 0
25(13.9) 50(27.8) 75(41.6) 100(55.6) 125(69.4)
delta T - Temperature Rise (ºF)
V65i SP(01) 7/2015
C U
Low Lead Content
NSF/ANSI 372
150(83.3)
SANITATION
FLOW TABLE
© 2015 Rinnai
V65i (VC2025FFU-US)
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
Simulation feed forward and feedback
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Top of heater - 6 inches(152mm) Front of heater - 6 inches(152mm)* Sides of heater - 2 inches(51mm)
Top of heater - 2 inches(51mm) Front of heater - 6 inches(152mm)* Sides of heater - 1/2 inch(13mm)
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Natural Gas: high fire 1.8” W.C. (4.5mbar) low fire 0.61” W.C. (1.5mbar) Propane Gas: high fire 2.8” W.C. (7.0mbar) low fire 0.87” W.C. (2.2mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Remaining flame (OHS) Thermal fuse Automatic frost protection
Back of heater - 0 inches Ground / bottom - 12 inches(305mm) From vent pipe - 0 inches
Back of heater - 0 inches Ground / bottom - 12 inches(305mm) From vent pipe - 0 inches
Warranty Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed
with an isolation valve kit; All other parts: 5 years*; Labor: 1 year
(* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water
heater is in series with a circulation system and all circulating water flows through the water heater)
DIMENSIONS
14.04 (356.6)
WEIGHT: 45.6 lb (20.7 kg)
9.27 (235.5)
5.05 (128.1)
0.4~1.8(10~45) Variable
2.67 (67.8)
DIMENSION
22.95 (583)
A
B
A (GAS)
A (COLD)
A (HOT)
B
C
C
Inches (mm)
1.31 (33.2)
1.93 (49)
1.35 (34.4)
4.21 (106.9)
1.17 (29.8)
E
D
DIMENSION
D
E
F
G
F
G
Inches (mm)
4.33 (110)
2.89 (73.3)
1.85 (47)
3.44 (87.3)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us