Rinnai REU-VB2735WD-US User Manual

)
Type of Appliance
Rinnai Model Number
Operation
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Temperature controlled, continuous flow, gas hot water system; certified for installation in manufactured (mobile) homes
REU-VB2735WD-US
Forced combustion
9,900 - 199,000 BTU/h (Natural Gas) 10,300 - 199,000 BTU/h (Propane)
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts
Normal 49 watts Standby 2 watts Anti-frost protection 104 watts
Direct electronic ignition
Minimum flow rate: 0.26 GPM Minimum activation flow rate: 0.4 GPM Maximum flow rate: 9.4 GPM (35° F rise)
98° - 120° F (factory default) Maximum temperature is selectable at 120° F or at 140° F; 98° - 185° F available with the MCC-91 controller for commercial and hydronic applications
120° F (factory default)
Natural or Propane (ensure unit matches gas type)
Installation
Energy Factor
Thermal Efficiency
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
FLOW TABLE
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
Hot Water Flow Rate (gpm
1.0
0.0
0 25 50 75 100 125 150
Outdoor only
Natural Gas: 0.82 Propane: 0.82
Natural Gas: 83% Propane: 83%
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device and fixed by-pass
20 - 150 PSI (recommended 30-80 PSI for maximum performance)
T – Temperature Rise (°F)
© 2010 Rinnai Corporation
R94LSe VB SP 8/2010
K
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.) (sea level)
NOx
Warranty
Simulation feed forward and feedback
MC-91-1US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-1US (for commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 12 inches
Front (Panel) - 24 inches
Front (Exhaust) - 24 inches
Top of heater - 2 inches
Front (Panel) - 0 inches *
Front (Exhaust) - 24 inches
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Ground / bottom - 12 inches
Sides of heater - 6 inches
Back of heater - 0 inches
Ground / bottom - 2 inches
Sides of heater - 1/8 inch
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 2.8” W.C. low fire 0.44” W.C. Propane Gas: high fire 5.0” W.C. low fire 0.93” W.C.
Meets California and Texas NOx Emission Rules
Heat exchanger: 12 years* for residential and 5 years* for commercial and hydronic applications; (10 years* if used with the Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
A
B
WEIGHT: 51 LBS (23 KG)
CD
E
H
F
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
GJI
DIM DESCRIPTION R75LSe
R94LSe
A Width 14 (355.6)
B Depth 9.9 (251.1)
C Height - Unit 22.9 (582)
D Height - with brackets 25.0 (634.2)
E Hot Water Outlet - from wall 3.8 (97.6)
F Hot Water Outlet - from center 4.3 (110)
G Cold Water Inlet - from wall 3.0 (76.6)
H Cold Water Inlet - from center 1.1 (27)
I Gas Connection - from wall 4.2 (105.6)
J Gas Connection - from center 3.5 (89)
From base to gas connection 1.6 (40)
K From base to cold connection 2.0 (50)
From base to hot connection 1.6 (41)