V53e (VAM1620W)
Type of Appliance
Rinnai Model Number Operation
Exhaust System Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Ignition System Hot Water Capacity Temperature Range Temperature Settings Approved Gas Types Installation Energy Factor
Temperature controlled, continuous flow, gas hot water system for residential applications.
REU-VAM1620W With or without remote controls (controller not included; error codes
displayed on front panel LED indicator) Forced combustion 20,200-120,000 BTU/h (Propane); 19,000-120,000 BTU/h (Nat.Gas) Appliance: AC 120 Volts - 60 Hz
Remote Control (optional): DC 12 Volts Normal 33 watts
Standby 2 watts Anti-frost protection 74 watts
Direct electronic ignition
0.6 to 5.3 GPM at a 35° F rise 98° - 140° (when using optional controller) 120° F (factory default) or 140° F Natural or Propane (ensure unit matches gas type) Outdoor only; residential only Natural Gas: 0.82 Propane: 0.82
Thermal Efficiency Service Connections
Water Flow Control Minimum/Maximum Water Supply Pressure
FLOW TABLE
6.0
5.0
4.0
3.0
2.0
1.0
Water Flow (gpm)
0.0 0 25 50 75 100 125 150
Natural Gas: 82% Propane: 82% Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device and fixed by-pass 20 - 150 PSI (50 PSI or above is recommended for maximum flow)
delta T - Temperature Rise (ºF)
© 2008 Rinnai Corporation
V53e SP-1 1/2008
V53e (VAM1620W)
Water Temperature Control Remote Controller (optional)
Remote Control Cable Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx Warranty
Simulation feed forward and feedback MC-91-1US
Deluxe controller: MC-100V-1US Bathroom controller: BC-100V-1US
98° - 140° F Wireless controller: MC-502RC-1US-MS Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 12 inches
Front (Panel) - 24 inches
Front (Exhaust) - 24 inches
Top of heater - 2 inches
Front (Panel) - 0 inches *
Front (Exhaust) - 24 inches
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
Sides of heater - 6 inches
Back of heater - 0 inches
Bottom of heater - 2 inches
Sides of heater - 1/8 inch
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 2.50” W.C. low fire 0.73” W.C. Propane Gas: high fire 2.40” W.C. low fire 0.75” W.C.
Meets California and Texas NOx Emission Rules Heat exchanger: 10 years* for residential; (* 3 years if used as a
circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
13.78 (350)
0.33 (8.5) 0.59 (15)
6.73
(171)
WEIGHT: 34.2 LBS (15.5 KG)
in (mm)
20.86 (530)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
22.48 (571)
4.1 (105) 3.3 (83)
2.8 (72)
0.4 (10)
2.1 (53)
2.4 (62)
Loading...