Rinnai REU-VA3237W User Manual

R98LSe (VA3237W)
Type of Appliance Rinnai model number Operation / Installation Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Temperature (without remote) Approved Gas Types Thermal Efficiency Service Connections
Water Flow Control
Temperature controlled, continuous flow, gas hot water system REU-VA3237W Forced combustion; outdoor only 19,000 - 237,000 BTU/h (Natural Gas or Propane) Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts Normal 99 watts
Standby 2 watts Anti-frost protection 116 watts
Direct electronic ignition
0.6 to 7.9 GPM (50° F rise) 0.9 to 9.8 GPM (35° F rise) 98° - 140° F (98° - 185° F available with the MCC-91 controller for
commercial and hydronic applications) 120° F (factory default) Natural or Propane (ensure unit matches gas type) Natural Gas: 83% Propane: 83% Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control and by-pass control
Minimum/Maximum Water Supply Pressure
FLOW TABLE
10
9 8
Water Flow Capacity Curve
7 6
5 4 3 2 1
Water Flow Rate (GPM
0
0255075100 125 1 50
© 2008 Rinnai Corporation
R98LSe SP 5/2008
15 - 150 PSI (50 PSI or above is recommended for maximum flow)
delta T -T em p erature Rise(F)
R98LSe (VA3237W)
Water Temperature Control Controller
Controller Cable Safety Devices
Clearances from Combustibles
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx Warranty
Simulation feed forward and feedback MC-91-1US (included)
Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) Wireless controller: MC-502RC-1US-MS (optional) MCC-91-1US (for commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 12 inches
Front (Panel) - 24 inches
Front (Exhaust) - 24 inches
Top of heater - 2 inches
Front (Panel) - 0 inches *
Front (Exhaust) - 24 inches
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 2.8” W.C. low fire 0.65” W.C. Propane Gas: high fire 3.8” W.C. low fire 0.80” W.C.
Meets California and Texas NOx Emission Rules Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
Sides of heater - 6 inches
Back of heater - 0 inches
Bottom of heater - 2 inches
Sides of heater - 1/8 inch
98° - 140° F
98° - 185° F
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
WEIGHT: 55 LBS