Rinnai REU-V2526W-US User Manual

R70e (2526W)
Type of Appliance Rinnai model number Operation Exhaust system Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Ignition System Hot Water Capacity Temperature Temperature (without remote) Approved Gas Types Installation Energy Factor Thermal Efficiency
Temperature controlled, continuous flow, gas hot water system REU-V2526W-US With or without remote controls, mounted in kitchen, bathroom, etc. Outdoor forced combustion 15,000 - 199,000 BTU/h (Natural Gas or Propane) Appliance: AC 120 Volts - 60 Hz
Remote Control: DC 12 Volts Normal 63 watts
Standby 5.5 watts Anti-frost protection 84 watts
Direct electronic ignition
0.6 to 6.5 GPM (50° F rise) 0.6 to 7.0 GPM (35° F rise) 98° - 140° F 120° F (factory default) Natural or Propane (ensure unit matches gas type) Outdoors only Natural Gas: 0.81 Propane: 0.80 Natural Gas: 84% Propane: 84%
Service Connections
Water Flow Control Minimum/Maximum Water Supply Pressure
FLOW TABLE
Water Flow Capacity Curves
(For 1 to 5 units manifolded in parallel)
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control and by-pass control 20 - 150 PSI (50 PSI or above is recommended for maximum flow)
40.0
35.0
30.0
25.0
20.0
15.0
10.0
Hot Water Flow Rate (gpm)
5.0
0.0 0 25 50 75 100 125 150
1 Unit 2 Units 3 Units 4 Units 5 Units
T – Temperature Rise (°F)
© 2005 Rinnai Corporation
2526W SP-1
2526W SP-1 4/2007
R70e (2526W)
Water Temperature Control Remote Controls
Remote Control Cable Safety Devices
Clearances from combustibles
Clearances from non-combustibles
Installations within RGB-25 Recess Box Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Simulation feed forward and feedback MC-91-1US (included)
Deluxe controller: MC-100V-1US Bathroom controller: BC-100V-1US Wireless controller (with transceiver): MC-502RC-1US -MS (optional)
Non-polarized two-core cable
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 12 inches
Front of heater - 24 inches
Sides of heater - 6 inches
Top of heater - 2 inches
Front of heater - 24 inches
Sides of heater - 1/2 inches
Clearance to recess box top, bottom, back, and sides: 0 inches Natural Gas: min 6” W.C. max 10” W.C.
Propane Gas: min 10.5” W.C. max 13.5” W.C. Natural Gas: high fire 3.4” W.C. low fire 0.56” W.C.
Propane Gas: high fire 5.1” W.C. low fire 0.88” W.C. Meets California and Texas NOx Emission Rules
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
Back of heater - 0 inches
Bottom of heater - 2 inches
Warranty
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
Residential only; heat exchanger 10 years*; all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, where the water heater is in series with a circulation system and all circulating water flows through the water heater, and where on-demand recirculation is not incorporated)
WEIGHT: 46 LBS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us