Rinnai REU-V2520FFUC-US User Manual

C53i (2520FFUC)
Type of Appliance Rinnai model number Operation Exhaust system Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Ignition System Hot Water Capacity Temperature Temperature (without remote) Approved Gas Types Installation Energy Factor Thermal Efficiency
Temperature controlled, continuous flow, gas hot water system REU-V2520FFUC-US With or without remote controls, mounted in kitchen, bathroom, etc. Direct vent, forced combustion 15,000 - 180,000 BTU/h (Natural Gas or Propane) Appliance: AC 120 Volts - 60 Hz
Remote Control: DC 12 Volts Normal 75 watts
Standby 5.5 watts Anti-frost protection 100 watts
Direct electronic ignition
0.6 to 5.3 GPM (50° F rise) 0.6 to 5.3 GPM (35° F rise) 120° - 185° F 140° F (factory default) Natural or Propane (ensure unit matches gas type) Indoor only Natural Gas: 0.81 Propane: 0.81 Natural Gas: 84% Propane: 84%
Service Connections
Water Flow Control Minimum/Maximum Water Supply Pressure
FLOW TABLE
Water Flow Capacity Curves
(For 1 to 5 units manifolded in parallel)
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device, no bypass 20 - 150 PSI (50 PSI or above is recommended for maximum flow)
© 2005 Rinnai Corporation
2520FFUC SP-1
2520FFUC SP-1 12/2006
C53i (2520FFUC)
Water Temperature Control Remote Controls
Remote Control Cable Safety Devices
Clearances from combustibles (suitable for closet, attic, and crawl space installations)
Clearances from non-combustibles
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx Warranty
Simulation feed forward and feedback MC-91-1US (included)
Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) Wireless controller (with transceiver): MC-502RC-1US -MS (optional)
Non-polarized two-core cable
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 6 inches
Front of heater - 6 inches
Sides of heater - 2 inches
Top of heater - 2 inches
Front of heater - 6 inches
Sides of heater - 1/2 inches
Natural Gas: min 6” W.C. max 10.5” W.C. Propane Gas: min 10” W.C. max 13.5” W.C.
Natural Gas: high fire 3.7” W.C. low fire 0.77” W.C. Propane Gas: high fire 4.2” W.C. low fire 0.93” W.C.
Meets California and Texas NOx Emission Rules Commercial only; heat exchanger 5 years*; all other parts 5 years*;
labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
WEIGHT: 49 LBS