12
ERROR MESSAGES
The water heater has the ability to check their own operation continuously. If a fault occurs,
an error code will flash on the digital display. This assists with diagnosing the fault, and may
enable you to overcome a problem without a service call.
Please quote the code displayed when enquiring about service. Some of these remedies
can not be checked by the user because they require the front to be taken off of the unit.
They are included so that you can give the information to the gas engineer.
* In all cases, you may be able to clear the error code by turning the hot water tap OFF, then ON
again. If this does not clear the error, try pushing the On/Off button OFF then ON again. If the Error
Code still remains contact Rinnai or your nearest service agent for advice.
** Faults caused by insufficient gas/water supply or gas/water quality and installation errors are not
covered by the manufacturer’s warranty.
Regular maintenance should be performed by a competent person in accordance with
the local regulations at least once annually.
Code
Displayed
Fault Remedy
- Noticeable reduction in water flow. Inlet water filter needs to be cleaned.
10
Not enough combustion air.
Check for physical blockages around air
intake or exhaust.
Check combustion fan.
11
No ignition / Gas supply.
Check gas solenoid valve, gas supply
and ignition unit.
12
Flame failure / Earth leakage.
Check gas solenoid valve, gas supply.
Check flame rod.
Check earth wire lead.
Check remote control.
14
High flame safety device. Check overheat circuit
16
Over temperature warning. Modulating control valve problem.
32
Outgoing water temperature
sensor faulty.
Check hot water thermistor and wire.
34
Combustion air temperature
sensor faulty.
Check air intake thermistor and wire.
52
Gas modulating valve faulty. Check gas modulating valve and PCB.
61
Combustion fan failure. Check combustion fan.
71
Micro-processor failure or
solenoid circuit failure.
Check solenoids and PCB.
72
Flame rod circuit error. Check flame rod and PCB.