![](/html/fe/fe59/fe59921fa081f961861782de8ca044c9e0b7216fe68bc7b3b7d3dd6bd20f8872/bg1.png)
Installation Instructions: Remote Thermostat for Direct Vent Furnaces
Kit Contents
Ref Part Name Qty
1 Sub PCB 1
2 Sub PCB Cover/Bracket 1
3 Power Harness 1
4 Central Timer Harness 1
3
4
5 Rubber Grommets 2
6 Circuit Board Spacer 4
7 Screws 2
8 Transformer 1
2
1
6
5
Field Supplied Components
Wall Thermostat
Thermostat Wire
Wire Nuts
This kit and instrucons contained herein are only for use with the following models of Rinnai Direct Vent Furnaces:
EX08CT and EX11CT
EX17CT and EX22CT
8
EX38CT
7
WARNING
To protect yourself from harm, before performing maintenance, turn o the electrical power supply by unplugging the power cord
or by turning o the electricity at the circuit breaker. (The control panel does not control the electrical power.)
![](/html/fe/fe59/fe59921fa081f961861782de8ca044c9e0b7216fe68bc7b3b7d3dd6bd20f8872/bg2.png)
Installaon Instrucons
1. Disconnect power from the Direct Vent Furnace.
2. Aach the wire harnesses to the sub pcb.
3. Install rubber grommets to sub PCB cover/bracket.
4. Aach the circuit board spacers to the sub PCB, then aach assembly to the sub PCB cover/bracket.
5. Secure sub PCB assembly to the direct vent furnace rear panel with the provided screws (2).