Rinnai RCE-229A User Manual

HOME OWNER/INSTALLER
FOR YOUR SAFETY
THIS MANUAL MUST BE READ IN ITS
ENTIRETY BEFORE OPERATING HEATER
SILENT SERVANT
CONVECTOR VENT-FREE SPACE HEATER
Owner’s Operation and Installation Manual
THIS IS AN UNVENTED GAS-FIRED HEATER. IT USES AIR (OXYGEN) FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED. REFER TO INSTALLATION INSTRUCTIONS ON PAGE 8.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY
PHONE IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
INSTALLER: MUST LEAVE MANUAL WITH UNIT AFTER INSTALLATION. OWNER: RETAIN THIS MANUAL SAFELY, FOR FUTURE REFERENCE.
TABLE OF CONTENTS
Page
SPECIFICATIONS .................................................................................................3
SAFETY DEVICES ................................................................................................3
IMPORTANT POINTS ............................................................................................4
SAFETY POINTS ...................................................................................................5
USAGE AND INSTALLATION MUSTS ...................................................................7
INSTALLATION INSTRUCTIONS ..........................................................................8
OPERATING INSTRUCTION PLATE .....................................................................11
ADDITIONAL CUSTOMER OPERATING INFORMATION ..................................12
MAINTENANCE / SERVICE ................................................................................17
TROUBLE SHOOTING CHART ...........................................................................18
SCHEMATIC DRAWINGS/PARTS LIST ..............................................................................20
ERROR MESSAGES ...........................................................................................27
LIMITED WARRANTY .....................................................................................back cover
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
GENERAL INFORMATION
THIS SERIES IS DESIGN CERTIFIED BY THE AMERICAN GAS ASSOCIATION LABORATORIES AS A VENT FREE CIRCULATOR AND MUST BE INSTALLED ACCORDING TO THESE INSTRUCTIONS.
ANY ALTERATION OF THE ORIGINAL DESIGN INSTALLED OTHER THAN AS SHOWN IN THESE INSTRUCTIONS OR USED WITH A TYPE OF GAS NOT SHOWN ON THE RATING PLATE, IS THE RESPONSIBILITY OF THE PERSON AND COMPANY MAKING THE CHANGE.
Model RCE-229Awww.rinnaina.com 2
SPECIFICATIONS
Model
Inp ut Rating
Btuh HIGH
Input Rating
Btuh LOW
Thermostat
Weight
in pounds
RCE-229A-N 6,000 2,000 YES
RCE-229A-P 6,000 2,500 YES
“-N” Models are for Natural Gas. (Inlet Pressure within 4.3"-10.5"W.C.) “-N” Models manifold pressure: 3.5"W.C. “-P” Models are for L. P. Gas. (Inlet Pressure within 4.7"-13"W.C.) “-P” Models manifold pressure: 4.4"W.C.
Gas connection pipe size 1/2" N.P.T. all models.
SAFETY DEVICES
Overheat Switch
When the heater gets too hot during operation (for example when the filters or air outlet louvers are blocked) this device turns the gas off automatically. Remove cause of overheat (clean filters) allow heater to cool, then re-ignite.
13.4
Dimensions
in inches
Height: 14 9/16"
Width: 14 3/4"
Depth: 6 11/16"
Fan CFM
Output
High: 64
Low: 46
Fuse
The electrical circuits are protected by a fuse. When the fuse blows, the heaters will not operate at all. The fuse must be replaced by an authorized person.
Flame Failure Device
This device automatically cuts off the gas supply to the heater in the event of a gas failure. To restore the gas supply to the heater, turn it off, then follow the ignition procedure.
Oxygen Depletion Safety Device
If the oxygen level in the room drops below a pre-set limit, this device cuts the gas supply off to the heater. If the oxygen depletion device operates, turn the heater off, ventilate the room, then follow the ignition procedure to re-light. Heater will not re-light until room is fully ventilated.
Tilt Switch
If the heater is knocked over, the tilt switch will cut the gas supply off. The fan keeps running. To restore the gas supply, stand the heater upright, turn it off then follow the ignition procedure. The tilt switch may also operate if the heater is jolted or picked up while in operation.
Power Failure
In the event of a power failure or power cut, the gas valves will automatically close. After the power is re-instated the appliance must be restarted manually.
Model RCE-229A 800-621-94193
IMPORTANT POINTS
UNPACK HEATER:
Check for damage. (DO NOT INSTALL DAMAGED HEATER.) If heater is damaged, contact your supplier for advice. Before installing a heater, check the label for the correct gas type (see label on side of heater). Refer to local gas authority for confirmation of gas type if you are in doubt.
INCLUDED IN CARTON:
Customers Operating Information/Manual Gas Valve
IMPORTANT
1. The appliance must be installed in accordance with state and local codes.
2. For information on gas rate, see data plate on the appliance.
3. When using this appliance, ensure that the room is correctly ventilated. Check the local gas authority for information on ventilation requirements.
4. The heater must not be installed where curtains or other combustible materials could come into contact with it. In some cases, curtains may need restraining. It must also be 2" (50mm) clear of walls.
5. This appliance is not designed to be built in.
6. If you move, check the gas type in the area where you are moving to. The local gas authority will be able to advise on local regulations.
7. This heater discharges a large volume of warm air at low level to provide even heat distribution. If the air in the room contains cooking vapor or cigarette smoke, and the heater is used on a carpet, the surface of the carpet may become discolored.
In addition, some nylon carpets contain dyes which may be affected by the warm air flow. Some soft vinyl surfaces are also subject to distortion, or discoloration by warm air. To prevent discoloration of carpets etc., a mat should be placed under the appliance, extending about 30"(750mm) in front of it.
8. This heater can be installed in a bathroom or a bedroom.
When installed in a bathroom or a bedroom, the heater must be wall mounted with optional wall mounting kit.
See page 26 of manual for part No. of wall mounting kit.
Model RCE-229Awww.rinnaina.com 4
SAFETY POINTS
Do not install this heater in areas where spray painting or plating is taking place, or in places such as hair dressers, where there may be a lot of fluff and dust, and where aerosols are used. May create strong odors and irritate eyes and sinuses.
Do not spray aerosols near this heater while it is in use. Many aerosols contain butane gas and can be a fire hazard. Use of aerosols, paint, polishes etc., while this heater is in use will cause unpleasant smells.
Do not move the heater while it is turned on.
Turn off heater when not in use and when away for long periods of time.
Do not allow children or elderly persons to sleep in the warm air discharge from the heater.
Model RCE-229A 800-621-94195
Do not sit on this heater.
SAFETY POINTS
Do not place wet articles on this heater, the water may drip into the electrical parts.
Do not turn the heater off by unplugging it from the wall, or while the fan is cooling the heater off. (This heater is not suitable for use with a plug in type timer.)
Do not allow children to put articles in the louvers. Supervise children playing near this heater.
Ventilate the room when this heater is in use. Correct, fixed ventilation is usually sufficient, consult your local gas authority for local regulations.
Keep away from flammable materials. Combustible materials must not be placed where the heater could ignite them. Do not place articles in front of the hot air discharge.
Do not place containers of liquid on top of the heater. Water in the heater can cause extensive damage.
Model RCE-229Awww.rinnaina.com 6
USAGE AND INSTALLATION MUSTS
1. Read these rules and the instructions carefully. Check all local codes. Failure to follow these could cause a malfunction of the heater resulting in death, serious bodily injury and/or property damage.
2. This heater is designed for use only with one type of gas, either L.P.G. or Natural Gas. Make sure that the type of gas to be supplied to this unit matches that shown on the rating plate on the heater. This unit is not convertible.
3. WARNING: Any change to this heater or its controls can be dangerous.
4. If a gas leak is suspected, turn heater off, turn gas supply valve off at regulator or appliance connecter valve. Open windows to ventilate area immediately and contact your dealer or gas company.
5. Installation and repair should be done by a qualified service person. Heater should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartment, burners and circulating air passageways be kept clean.
6. Keep area near the heater clear and free from combustible materials, gasoline and other flammable vapors and liquids.
7. Due to its high temperature, the heater should be located out of traffic and away from furniture and draperies.
8. Do not place clothing or flammable material on or near the heater.
9. Any safety panel or guard removed for servicing must be replaced prior to operating the heater.
10. An unvented gas heater will increase the amount of humidity in the room.
11. This heater is intended for space heating purposes only. Do not use for other purposes such as drying clothes or baking paints.
12. Do not touch the outlet area while the heater is in use. To avoid burns, do not move the heater during use and avoid touching the heater just after turning off.
13. Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition.
14. Young children should be carefully supervised when they are in the same room with the heater.
15. L.P.G containers must not be installed indoors.
16. Do not install in a windy area such as facing a window or a door leading to the outside.
17. Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
18. Carpet lint or cigarette smoke may pass through the heater, discolor, and be deposited into the room.
19. This unit discharges a large volume of warm air at a low level to provide even heat distribution. If the air in the room contains cooking vapors, cigarette smoke, and if used on carpet, the surface in front of unit is subject to discoloration. Some carpets contain dyes which can be effected by warm air flow and could discolor. To aid in prevention of discoloration, place a mat under the unit to extend to the front 30 “.
Model RCE-229A 800-621-94197
INSTALLATION INSTRUCTIONS
NOTICE BEFORE INSTALLATION
The heater must be installed by a qualified service person according to this installation instructions.
When used without adequate combustion and ventilation heater air may give off carbon monoxide.
Check your local building codes for the proper method of installation. In the absence of local codes, this heater installation must conform with American National Standard (National Fuel Gas Code) ANSI Z223.1.
Available from the American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018, or from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
All correspondence should refer to Model No., Serial No., and type of gas.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
This appliance may be installed in an aftermarket manufactured (mobile) home where not prohibited by state or local code.
Aftermarket = completion of sale, not for purpose of resale from manufacturer.
This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
The National Fuel Gas Code ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kW) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kW) of the aggregate input rating of all appliances installed in that space.
Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
The following formula can be used to determine the maximum heater rating per the definition of unconfined space:
BTU/HR =
Consider two connecting rooms with an open area between, with the following dimensions:
BTU/HR = (15 1/2+12) X (12) X (8) X 1000
If there is a door between the two rooms that can be closed the calculation must be based only on the room with the heater.
BTU/HR = (15 1/2) X (12) X (8) X 1000
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable local codes.
(L1 +L2)Ft X (W)Ft X (H) Ft X 1000
50
50
= 52800 BTU/HR
50
= 29760 BTU/HR
Model RCE-229Awww.rinnaina.com 8
INSTALLATION INSTRUCTIONS
Unusually tight construction is defined as construction where:
a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a
rating of 1 perm (6X10
b) Weather stripping has been added on openable windows and doors, and
c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole
plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
LOCATION AND CLEARANCES
1. The minimum clearances from the combustible materials areas follows:
2 inches from top
2 inches from back
2 inches from side
30 inches from front
0 inches from bottom
2. This heater may be installed on combustible flooring. When the heater is installed directly on carpeting, tile or other combustible material other than wood flooring, the heater shall be installed on a metal or wood panel extending the full width and depth of the heater.
-11
kg per pa-sec-m2) or less with openings gasketed or sealed, and
3. Adequate clearances for accessibility for purposes of servicing and proper operation must be provided.
4. Adequate clearances around air openings must be provided.
5. Right and left sides are determined when facing the front.
6. Do not install in areas where curtains, drapes, clothing, or other moving flammables are within 12 inches of this unit.
7. This unit is designed to mount directly to a wall with optional wall mounting kit. See page 24 for part No. of wall mounting kit.
8. Make certain of adequate combustion and ventilation air.
9. Do not oversize the heater to the room.
GAS CONNECTION
1. The gas supply line shall be gas-tight, sized and so installed as to provide a supply of gas sufficient to meet the maximum demand of the heater without loss of pressure.
2. A shut off valve (or appliance connector valve) should be installed in the upstream of the gas line to permit servicing.
3. Flexible pipe and any appliance connector valve used for gas piping shall be types approved by nationally recognized agencies.
Model RCE-229A 800-621-94199
Loading...
+ 19 hidden pages