Rinnai R98EASME User Manual

R98eASME (V3237W-ASME)
R
Type of Appliance Rinnai model number Operation Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
This model has been built in accordance with the requirements of the ASME Boiler and Pressure Vessel Code and has received the Certificate of Authorization from the National Board. The heat exchanger has the NB and the HLW stamps.
Temperature controlled, continuous flow, gas hot water system REU-V3237W-ASME Forced combustion 19,000 - 237,000 BTU/h (Natural Gas or Propane) Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts Normal 72 watts
Standby 2 watts Anti-frost protection 116 watts
Direct electronic ignition
0.6 to 8.0 GPM (50° F rise) 0.9 to 9.8 GPM (35° F rise) 98° - 140° F 120° F (factory default) Natural or Propane (ensure unit matches gas type) Outdoor only
Thermal Efficiency Service Connections
Water Flow Control Minimum/Maximum Water Supply Pressure
FLOW TABLE
Water Flow Capacity Curve
Natural Gas: 85% Propane: 83% Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control and by-pass control 15 - 150 PSI (50 PSI or above is recommended for maximum flow)
© 2008 Rinnai Corporation
3237W-ASME SP-1 4/2008
R98eASME (V3237W-ASME)
Water Temperature Control Controller
Controller Cable Safety Devices
Clearances from combustibles
Clearances from non-combustibles * 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx Warranty
Simulation feed forward and feedback MC-91-1US (included)
Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) Wireless controller (with transceiver): MC-502RC-1US -MS (optional)
Non-polarized two-core cable, minimum 22 gauge
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 12 inches
Front (Panel) - 24 inches
Front (Exhaust) - 24 inches
Top of heater - 2 inches
Front (Panel) - 0 inches *
Front (Exhaust) - 24 inches
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 3.0” W.C. low fire 0.67” W.C. Propane Gas: high fire 3.7” W.C. low fire 0.83” W.C.
Meets California and Texas NOx Emission Rules Residential only; heat exchanger 10 years*; all other parts 5 years*;
labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, where the water heater is in series with a circulation system and all circulating water flows through the water heater, and where on-demand recirculation is not incorporated )
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
Sides of heater - 6 inches
Back of heater - 0 inches
Bottom of heater - 2 inches
Sides of heater - 1/8 inch
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
WEIGHT: 55 LBS