Rinnai R75LSI User Manual

R75LSi (VA2528FFUD)
Type of Appliance Rinnai Model Number Operation / Exhaust System Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Ignition System Hot Water Capacity Temperature
Temperature (without remote) Approved Gas Types Installation Energy Factor Thermal Efficiency
Temperature controlled, continuous flow, gas hot water system REU-VA2528FFUD(A)-UC Forced combustion / Direct vent 15,000 - 180,000 BTU/h (Natural Gas and Propane) Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts Normal 65 watts
Standby 2.0 watts Anti-frost protection 100 watts
Direct electronic ignition
0.6 to 7.5 GPM (35° F rise) 98° - 120° F (factory default) Maximum temperature is selectable at
120° F or at 140° F; 98° - 160° F available with the MCC-91 controller for commercial and hydronic applications
120° F (factory default) Natural or Propane (ensure unit matches gas type) Indoor only Natural Gas: 0.82 Propane: 0.82 Natural Gas: 84% Propa ne: 84%
Service Connections
Water Flow Control Minimum/Maximum Water Supply Pressure
FLOW TABLE
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
Water Flow (gpm)
0.0 0 25 50 75 100 125 150
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device and fixed by-pass 20 - 150 PSI (recommended 30-80 PSI for maximum performance)
delta T - Temperature Rise (ºF)
© 2008 Rinnai Corporation
R75LSi SP 8/2008
)
R75LSi (VA2528FFUD)
Water Temperature Control Controller
Controller Cable Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Clearances from Non-combustibles
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx Warranty
Simulation feed forward and feedback MC-91-1US (part of the front panel)
Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) Wireless controller: MC-502RC-1US-MS (optional) MCC-91-1US (for commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 6 inches
Front of heater - 6 inches
Sides of heater - 2 inches
Top of heater - 2 inches
Front of heater - 6 inches
Sides of heater - 1/2 inch
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 2.7” W.C. low fire 0.52” W.C. Propane Gas: high fire 4.4” W.C. low fire 0.92” W.C.
Meets California and Texas NOx Emission Rules Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
14 (355.6)
9.6 (244.5)
WEIGHT: 50 LBS (23 KG)
in (mm)
22.9 (582)
25.5 (648 .2)
3.6 (91)
1.1 (27)
4.3 (110)
3.5 (89)
The wall bracket is adjustable to allow an additional 1.57 inches (40 mm).
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
2.8 (70)
3.9 (99