Rinnai R50LSI, R75LSI, R94LSI, R98LSI, R98LSI-ASME User Manual

Direct Vent Tankless Water Heater
Operation and Installation Manual
R50LSi ............... REU-VA2019FFUD
R75LSi ............... REU-VA2528FFUD(A)
R94LSi ............... REU-VA2535FFUD
R98LSi ............... REU-VA3237FFU
R98LSi-ASME.... REU-VA3237FFU-ASME
FOR INDOOR APPLICATIONS ONLY
Table of Contents ....................2
Consumer Safety Information ..4
Operating Instructions..............5
Maintenance ............................12
Register your product at www.rinnairegistration.com or call 1-866-RINNAI1 (746-6241)
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
If you cannot reach your gas supplier, call the fire
department.
ANS Z21.10.3
CSA 4.3
— Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Error Codes .............................13
Installation Instructions ............17
Consumer Support...................42
R
REU-VA3237FFU-ASME
This model has been built in accordance with the requirements of the ASME Boiler and Pressure Vessel Code and has received the Certificate of Authorization from the National Board. The heat exchanger on this unit has the NB and HLW stamps.
Table of Contents
Specifications ......................................................3
Consumer Safety Information
Safety Definitions .............................................4
Safety Behaviors and Practices .......................4
Safety Features ................................................4
Description of Operation ....................................5
Operating Instructions
Features Available on Temperature
Controllers ........................................................5
Temperature Controllers - Models ...............6, 7
Setting the Temperature...................................8
Temperature Options Without
a Temperature Controller .................................8
Temperature Ranges .......................................9
Setting the Sound Volume................................9
Setting the Clock ..............................................9
Using the Water Smart Bath Fill Function ......10
Overview....................................................10
Setting the Water Volume..........................10
Filling the Tub ............................................11
Setting Controller to Mute...............................11
Maintenance
Cleaning.....................................................12
Vent System...............................................12
Motors ........................................................12
Temperature Controller..............................12
Lime / Scale Buildup ..................................12
Snow Accumulation ...................................12
Visual Inspection of Flame.........................12
Error Codes
Error Code Table.......................................13,14
Trouble Shooting for Common Issues............15
Accessing Operating Information ...................15
Water Quality..................................................15
Flushing the Heat Exchanger.........................16
(Error Code: LC or 00)
Installation Instructions....................................17
General Instructions .......................................17
Clearances from Appliance ............................18
Attachment of the Water Heater.....................18
Electrical Connection .....................................19
Gas Piping
General Instructions.................................19
Pipe Sizing Procedure - Example ............20
Water Piping
General Instructions.................................21
Pressure Relief Valve ..............................21
Freeze Protection.....................................21
Freeze Protection Piping ................................22
Recommended Piping for Basic Installation ..23 Recommended Piping for
Circulation Systems .......................................24
Optional Piping for Circulation Systems.........25
Venting Instructions
Intake / Exhaust Guidelines .....................26
Condensate..............................................26
Maximum Vent Length .............................27
Vent Products ..........................................28
Flue Terminal Clearances (ANS Z21.10.3 CSA 4.3
Additional Clearances ....................................30
Flue Installation - Concentric Venting
(R50LSi, R75LSi, R85LSi)..............................31
Flue Installation
(R98LSi, R98LSi-ASME) ..........................32, 33
High Altitude Installation.................................34
Connecting Multiple Water Heaters................34
Temperature Controller Installation
Location....................................................35
Configurations ..........................................35
Cable Lengths and Size...........................35
Mounting the Controller............................ 36
Operating Instructions ....................................37
Technical Data
Pressure Drop Curve .....................................38
Outlet Flow Data.............................................38
Space Heating ................................................39
Dimensions.....................................................40
Ladder Diagram..............................................41
Consumer Support
Warranty Information......................................42
Limited Warranty ......................................42, 43
).............................29
2 VA Series Indoor LS Manual
Specifications
Model
Minimum Gas Consumption Btu/h 15,000 19,000
Maximum Gas Consumption Btu/h 150,000 180,000 237,000
Hot water capacity (Min - Max) *
Hot water capacity (45°F rise)
Default Temperature Setting (no controller) 120º F (49º C)
Temperature Controller Default Setting 104º F (40º C)
Maximum Temp Setting (commercial **) 160º F (71º C) 185º F (85º C)
Maximum Temp Setting (residential)
see Temperature Ranges for more information
Minimum Temperature Setting 98º F (37º C)
Weight 50 lb (23 kg) 55 lb (25 kg)
Efficiency Rating
Noise level
Electrical Consumption
By-Pass Control
Minimum Gas Supply Pressure
Maximum Gas Supply Pressure
Type of Appliance Direct Vent, Temperature controlled continuous flow gas hot water system.
Operation With or without remote controls, mounted in kitchen, bathroom, etc.
Approved Gas Type Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.
Connections Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignition System Direct Electronic Ignition
Electric Connections Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)
Water Temperature Control Simulation Feedforward and Feedback.
Water Supply Pressure Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure 150 PSI
Remote Control Cable Non-Polarized Two Core Cable (Minimum 22 AWG)
Normal 79 W 99 W
Standby
Anti-frost Protection
Natural Gas 5.0 inch W.C.
Propane 8.0 inch W.C.
Natural Gas 10.5 inch W.C.
Propane 13.5 inch W.C.
R50LSi
0.6 - 5.0 GPM
(2.3 - 18.9 L/min)
5.0 GPM
(18.9 L/min)
100 W 116 W
R75LSi
0.6 - 7.5 GPM
(2.3 - 28.4 L/min)
6.7 GPM
(25.4 L/min)
Fixed Electronic
R94LSi
199,000 Natural
Gas
190,000 Propane
0.6 - 9.4 GPM
(2.3 - 35.5 L/min)
7.1 GPM
(27.0 L/min)
140º F (60º C)
84.0%
49 dB
2 W
R98LSi
0.6 - 9.8 GPM
(2.3 - 37 L/min)
(32.2 L/min)
R98LSi-
ASME
8.5 GPM
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
** for commercial and hydronic applications requiring higher temperatures
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.
VA Series Indoor LS Manual 3
Consumer Safety Information
Safety Definitions
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and
others.
DANGER
WARNING
CAUTION
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices.
Safety Behavior and Practices
WARNING
Keep the area around the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
This appliance is equipped with a three-prong plug for your protection against shock hazard and should be plugged directly into a properly grounded three­prong receptacle. Do not cut or remove the ground prong from this plug.
Any alteration to the appliance or its controls can be dangerous and will void the warranty.
Always check the water temperature before entering a shower or bath.
Safety Features
Overheat: The appliance will automatically shut down when the appliance exceeds a predetermined temperature.
Flame Failure: The appliance will automatically shut down if the burner flame is extinguished.
Power Failure: The appliance will cut off the gas if it loses electrical power.
Power Surge Fuse: A glass fuse protects against overcurrent. If the fuse blows then all indicator lamps will be off.
Fusible Link: In case the overheat feature does not prevent the temperature from rising then the fusible link will break shutting off the appliance.
4 VA Series Indoor LS Manual
Description of Operation
The Rinnai water heater is one of the most advanced water heaters available. It provides a continuous supply of hot water at a preset temperature. This appliance is direct vent where air is brought in from the outside and combustion gases are exhausted to the outside.
While electricity, water, and gas supplies are connected, the Rinnai water heater produces hot water whenever a hot water tap is open.
Ignition is electronic. There is no pilot light consuming gas while the water heater is not being used. The gas burner lights automatically when the hot water tap is opened and goes out when the tap is closed.
Installation of the temperature controller is highly recommended. The temperature controller can set the temperature within a specific range and can provide error codes to diagnose any problems.
The temperature of the outgoing hot water is constantly monitored. The Rinnai water heater may adjust the water flow in order to maintain the temperature setting. The water flow may vary from summer to winter due to the difference in ground water temperature.
Operating Instructions
Features Available on Temperature Controllers
The MC-91 temperature controller is supplied with the appliance. Additional functions are available through the use of optional controllers.
MC-91
Features
MC-100
MCC-91
BC-100
MC-502
Description
Sends a short series of beeps to all controllers in the system. It is
Call
Clock
Error Codes
Function
In Use Indicator
ON/OFF Button
Power Save
Priority Button / Indicator
Sound Volume
Temperature Display
Thermostat
12 hour AM/PM clock.
When a fault is detected an error code flashes at the temperature
Used on this model to set the clock or sound volume.
Indicates that hot water is being supplied (i.e. a hot water tap is
Used to turn the water heater ON or OFF.
Indicates that this controller is setting the temperature . Priority
Used to adjust the voice prompt volume.
Shows the temperature setting.
Increases or decreases the temperature setting.
Allows the temperature controller to be in an energy saving
not an intercom.
display on models MC-91, MCC-91, and MC-502; and flashes at the clock display on models MC-100 and BC-100.
open).
mode.
can be switched to another controller by pressing its Priority Button when no hot water is running.
Water Smart / Bath Fill Button / Indicator
Water Volume
VA Series Indoor LS Manual 5
Used to select the Water Smart / Bath Fill Function to fill a bath
with a predetermined volume of water.
Used to select the water volume for the Water Smart / Bath Fill
Function.
Temperature Controllers - Models
MC-91-1US & MCC-91-1US
Dimensions (inches): 3.5 W x 4.75 H x 0.75 D
The MC-91 controller is the standard temperature controller that is supplied with the water heater. On indoor models it is integrated into the front panel. The MCC-91 controller is for commercial and hydronic applications requiring higher temperatures. When the MCC-91 controller is connected, these higher temperatures are available on all controller models in the system. Refer to the section on temperature ranges.
In Use
Indicator
Priority
Indicator
Temperature
Display
Priority
Button
Thermostat
MC-502RC-1US-S * (Wireless)
Dimensions (inches): 4.33 W x 5.90 H x 1.16 D
Temperature
Display
Thermostat
ON/OFF
Button
ON/OFF
Button
Priority
Indicator
In Use
Indicator
Priority
Button
* Requires the transceiver, MC-
502RC-1US-M, to be connected to the water heater.
Refer to the MC-502RC-1US-S manual and the Wireless Controller Installation Instructions for complete details on features, operation, and installation.
6 VA Series Indoor LS Manual
Temperature Controllers - Models
BC-100V-1US
Dimensions (inches): 8.0 W x 4.125 H x 0.875 D
NOTICE
Priority
Button and
Indicator
Call
Clock
The BC-100V controller is water resistant. Avoid splashing the controller.
In Use
Indicator
Temperature
Display
Water Smart
Bath Fill Indicator
ON/OFF
Button
Water Smart
Bath Fill
Button
Power Save
Water Volume
Thermostat
Dimensions (inches): 5.0 W x 4.75 H x 0.75 D
Sound Volume
In Use
Indicator
Temperature
Display
Clock
Call
MC-100V-1US
Thermostat
Function
Priority Button
and Indicator
ON/OFF
Button
VA Series Indoor LS Manual 7
Setting the Temperature
DANGER
1. Press the “Priority button” on the temperature controller. The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water.
The priority can only be changed
while no hot water is running.
Hot water can be dangerous, especially for infants or children, the elderly, or infirm. There is hot water scald potential if the thermostat is set too high.
Water temperatures over 125º F (51º C) can cause severe burns or scalding resulting in death.
Hot water can cause first degree burns with exposure for as little as:
3 seconds at 140º F (60º C)
20 seconds at 130º F (54º C)
8 minutes at 120º F (48º C)
Test the temperature of the water before placing a child in the bath or shower.
Do not leave a child or an infirm person in the bath unsupervised.
NOTICE
NOTICE
While any hot water is being provided, the temperature setting can only be adjusted between 98º F and 110º F.
Check local codes for the maximum water temperature setting allowed when used in nursing homes, schools, day care centers, and all other public applications.
2. Press the ▲ or ▼ buttons to obtain the desired temperature setting.
All hot water sources are able to
provide water at this temperature setting until it is changed again at this or another temperature controller.
NOTICE
NOTICE
If a newly installed unit with a controller has not been powered for at least 6 hours then the temperature will return to the default setting of 104º F (40º C) if power is interrupted.
There may be a variation between the temperature displayed on the temperature controller and the temperature at the tap due to weather conditions or the length of pipe to the water heater.
Temperature Options Without a Temperature Controller
The default temperature setting for this appliance installed without a temperature controller is 120º F (49º C). If desired the temperature setting can be changed to 140º F (60º C) by adjustment of a dip switch.
Set dip switch 5 to ON to obtain 140º F water temperature setting.
Set dip switch 5 to OFF (default) to obtain 120º F water temperature setting.
WARNING
DO NOT adjust the other dip switches unless specifically instructed to do so.
120º F (49º C) 140º F (60º C)
Switch No.
ON
O F F
1
2
3
4
5
6
7
8
Switch No.
ON
O F F
1
2
3
4
5
6
7
8
8 VA Series Indoor LS Manual
Temperature Ranges
This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied or when more than 1 tap is in use. The water heater can deliver water at only one temperature setting at a time. The available temperatures for a given model are provided below.
Model
R50LSi R75LSi
R94LSi R98LSi
R98LSi-ASME
Temp in Celsius ºC 37 38 39 40 41 42 43 46 49 52 54 57 60
* MCC-91 Temperature Controller These settings require the MCC-91 controller. When the MCC-91 controller is connected, these higher
temperatures are available on all controller models in the system. Use of an MCC-91 controller in a residential dwelling will reduce the warranty coverage to that of a commercial warranty application.
The MCC-91 controller is intended for commercial and hydronic applications only. If an MCC-91 controller is used in a residential dwelling for a hydronics application, a mixing valve must also be installed to limit the potable hot water temperature to a safe temperature. Water temperatures over 125º F (51º C) can cause severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be liable for damages resulting from such misuse or misapplication.
Suggested temperatures are
98 100 102 104 106 108 110 115 120 125 130 135 140
98 100 102 104 106 108 110 115 120 125 130 135 140
Temperature Settings Available (ºF)
150 * 160*
150* 160* 185
66 * 71 * 85
These temperatures are suggestions only.
*
*
Kitchen 120 ºF (49º C)
Shower 98º - 110º F (37º - 43º C)
Bath Fill 102º - 110º F (39º - 43º C)
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” button for 5 seconds while the water heater is OFF.
A temperature lower than 98º F (37º C) can be obtained at the tap by mixing with cold water.
Setting the Sound Volume (Voice Prompt)
MC-100V Press the “Function” button to
adjust the voice prompt volume. The default sound volume is set to Medium. Each subsequent press of the or button cycles through the volume levels in the order below.
Medium Volume
(default)
High Volume
Off Volume
(beep)
BC-100V Press the “Sound Vol.” button to
adjust the voice prompt volume. The default sound volume is set to Medium. Each subsequent press of the button cycles through the volume levels in the order below.
Off Sound
(no beep)
Low Volume
VA Series Indoor LS Manual 9
Using the Water Smart / Bath Fill Function
Overview
This function is exclusive to the BC-100V temperature controller. The bath fill function allows the consumer to fill a tub with a preset volume of water at a preset temperature. This is done by pressing the bath fill button on the BC-100V controller while no hot water is flowing and then opening only the hot water tap. The water heater will stop the hot water flow when the preset volume has been reached. The hot water tap should then be closed and the bath fill button pressed.
The temperature settings for the bath fill function are limited to those in the table below.
Bath Fill Temperature Settings Available
ºF 98 100 102 104 106 108 110 115 120
ºC 37 38 39 40 41 42 43 46 49
NOTICE
Multiple
Water
Heaters
NOTICE
Power
Loss
NOTICE
Anti-scald
Fixtures
The bath fill function will not work properly if it is connected to multiple water heaters. The tub will overfill because the bath fill function is not able to measure the water volume when connected to multiple water heaters.
If power is lost during the bath fill function, the water heater will shut down but the water will continue to flow. When power returns, the water shuts off and Error Code 03 appears on the controller.
If power is lost after the bath has filled but before the bath fill function button is de-selected, then the water will not flow during the power loss or after the power is returned. Once power returns, close the hot water tap and de-select the bath fill function. No error code appears.
Do not use with single handle fixtures that have anti-scald features built into them. These fixtures allow a predetermined amount of cold water which is not taken into account by the bath fill function.
Setting the Water Volume
The default volume is set to 25 gallons. The volume can be set between 10 and 120 gallons.
1. Press the “Priority button” on the temperature controller. The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water.
2. Press the “Temp” or buttons to obtain the desired temperature setting.
3. Press the “Water Vol.” or buttons to obtain the desired water volume in gallons.
NOTICE
To Prevent
Over Filling
Be careful not to overfill the bath. An average bath volume is 60 gallons. When filling the bath using this function for the first time:
Monitor and remain by the bath while the water is running.
Use a low bath fill volume less than 25 gallons
10 VA Series Indoor LS Manual
Using the Water Smart / Bath Fill Function
Filling the Tub
ON!
HOT
COLD
1. Press the “Water Smart / Bath Fill” button once. The button will illuminate, a tone will sound, and the word “Bath” will appear next to the temperature setting.
2. The voice prompt will announce “The hot water system is ready. Open the hot water tap.” Open the hot water tap. The “In Use” indicator will illuminate on all controllers. The hot water will begin to flow.
NOTICE
To Stop the Bath Fill Before it Finishes
To stop the water flow during the Bath Fill function, press the “Water Smart / Bath Fill” button. The button will flash and the voice prompt will announce, “Hot water is not available. Turn off all hot water taps and push the Bath Fill button.” Follow the voice prompt instructions.
ON!
HOT
COLD
3. When the preset volume of water has been produced then
the water flow will cease
the “Water Smart / Bath Fill”
button will flash
a tone will sound
the voice prompt will
announce, “Bath fill is complete. Turn off the bath hot water tap and push the Bath Fill button.”
4. Turn off the bath hot water tap and push the Bath Fill button. The water heater will not allow hot water to flow from any source until the “Water Smart / Bath Fill” button is pushed. The button light will go out and the word “Bath” will disappear from the display.
NOTICE
When
Other Taps
Are Open
During the bath fill function, any hot water flowing at other locations, subtracts from the total amount of water for the bath. For example if the bath fill function is set for 50 gallons and 5 gallons of hot water are used at other locations during the fill period then the bath will only fill with 45 gallons.
Setting Controller to Mute
Models MC-91 and MCC-91
To eliminate the beeps when keys are pressed or to turn the beeps back on, press and hold both the ▲and ▼ buttons until a beep is heard (approximately 5 seconds).
Setting the Clock
MC-100V Press the “Function” button twice within 10 seconds to set the clock. Press the or
button to reach the desired time. The clock on the BC-100V automatically shows
the time which has been set on the MC-100V.
VA Series Indoor LS Manual 11
Maintenance
WARNING
Turn off the electrical power supply, the manual gas valve and the manual water control valve whenever servicing the unit.
Repairs and maintenance should be performed by a qualified service technician. The appliance should be inspected annually by a qualified service technician. Verify proper operation after servicing.
Cleaning
It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.
Clean as follows:
1. Turn off and disconnect electrical power. Allow to cool.
2. Remove and clean the water inlet filter.
3. Remove the front panel by removing 4 screws.
4. Use pressurized air to remove dust from the main burner, heat exchanger, and fan blades. Do not use a wet cloth or spray cleaners on the burner. Do not use volatile substances such as benzene and thinners. They may ignite or fade the paint.
Snow Accumulation
Keep the area around flue terminal free of snow and ice. The appliance will not function properly if the intake air or exhaust is impeded (blocked or partially blocked) by obstructions.
Visual Inspection of Flame
The burner must flame evenly over the entire surface when operating correctly. The flame must burn with a clear, blue, stable flame. See the parts breakdown of the burner for the location of the view ports.
The flame pattern should be as shown in the figures below.
5. Use soft dry cloth to wipe cabinet.
Vent System
The vent system should be inspected at least annually for blockages or damage.
Motors
Motors are permanently lubricated and do not need periodic lubrication. Keep fan and motor free of dust and dirt by cleaning annually.
Temperature Controller
Use a soft damp cloth to clean the temperature controller. Do not use solvents.
Lime / Scale Build-up
If you receive Error Code “LC”, refer to the procedure,
Flushing the Heat Exchanger. Refer to the section on Water Quality to see if your water needs to be treated
or conditioned. (When checking maintenance code history, “00” is substituted for “LC”.)
12 VA Series Indoor LS Manual
Error Codes
The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the Display of the temperature controller. This assists with diagnosing the fault and may enable you to overcome a problem without a service call. Please identify the code displayed when inquiring about service.
WARNING
Some of the checks below may need to be done by a qualified service technician. Call a service technician for any remedy that involves gas or electricity. Call a service technician if you have any doubt or reservation about performing the remedy yourself.
Code Fault Remedy
02
03
10
11
12
No burner operation during freeze protection mode
Power interruption during Bath Fill (Water will not flow when power returns).
Air Supply or Exhaust Blockage
No Ignition Check that the gas is turned on at the water heater, gas meter, or cylinder.
Flame Failure Check that the gas is turned on at the water heater and gas meter. Check for
Service Call
Turn off all hot water taps. Press ON/OFF twice.
Ensure Rinnai approved venting materials are being used. Check that nothing is blocking the flue inlet or exhaust. Check all vent components for proper connections. Ensure vent length is within limits. Ensure condensation collar was installed correctly. Verify dip switches are set properly. Check fan for blockage.
Ensure gas type and pressure is correct. Ensure gas line, meter, and/or regulator is sized properly. Bleed all air from gas lines. Verify dip switches are set properly. Ensure appliance is properly grounded. Disconnect EZConnect Ensure igniter is operational. Check igniter wiring harness for damage. Check gas solenoid valves for open or short circuits. Remove burner cover and ensure all burners are properly seated. Remove burner plate and inspect burner surface for condensation or debris.
obstructions in the flue outlet. Ensure gas line, meter, and/or regulator is sized properly. Ensure gas type and pressure is correct. Bleed all air from gas lines. Ensure proper Rinnai venting material was installed. Ensure condensation collar was installed properly. Ensure vent length is within limits. Verify dip switches are set properly. Ensure appliance is properly grounded. Disconnect keypad. Disconnect EZConnect™ or MSA controls to isolate the problem. Check power supply for loose connections. Check power supply for proper voltage and voltage drops. Ensure flame rod wire is connected. Check flame rod for carbon build-up. Disconnect and reconnect all wiring harnesses on unit and PC board. Check for DC shorts at components. Check gas solenoid valves for open or short circuits. Remove burner plate and inspect burner surface for condensation or debris.
or MSA controls to isolate the problem.
VA Series Indoor LS Manual 13
Code Fault Remedy
14
16
32
33
34
52
61
65
71
72
LC
No code
Thermal Fuse Check gas type of unit and ensure it matches gas type being used.
Check for restrictions in air flow around unit and vent terminal. Check for low water flow in a circulating system causing short-cycling. Ensure dip switches are set to the proper position. Check for foreign materials in combustion chamber and/or exhaust piping. Check heat exchanger for cracks and/or separations. Check heat exchanger surface for hot spots which indicate blockage due to scale build-
up. Refer to instructions in manual for flushing heat exchanger. Measure resistance of safety circuit. Ensure high fire and low fire manifold pressure is correct. Check for improper conversion of product.
Over Temperature Warning
Outgoing Water Temperature Sensor Fault
Heat Exchanger Outgoing Temperature Sensor Fault
Combustion Air Temperature Sensor Fault
Modulating Solenoid Valve Signal Abnormal Combustion Fan Failure
Water Flow Control Fault
SV0, SV1, SV2, and SV3 Solenoid Valve Circuit Fault Flame Sensing Device Fault
Scale Build-up in Heat Exchanger (when checking maintenance code history, “00” is substituted for “LC”)
Nothing happens when water flow is activated.
Check for restrictions in air flow around unit and vent terminal. Check for low water flow in a circulating system causing short-cycling. Check for foreign materials in combustion chamber and/or exhaust piping. Check for clogged heat exchanger. Check sensor wiring for damage. Measure resistance of sensor. Clean sensor of scale build-up. Replace sensor. Check sensor wiring for damage. Measure resistance of sensor. Clean sensor of scale build-up. Replace sensor. Check for restrictions in air flow around unit and vent terminal. Check sensor wiring for damage. Measure resistance of sensor. Clean sensor of scale build-up. Ensure fan blade is tight on motor shaft and is in good condition. Replace sensor. Check modulating gas solenoid valve wiring harness for loose or damaged terminals. Measure resistance of valve coil. Ensure fan will turn freely. Check wiring harness to motor for damaged and/or loose connections. Measure resistance of motor winding. The water flow control valve has failed to close during the bath fill function. Immediately turn off the water and discontinue the bath fill function. Contact a state qualified or licensed contractor to service the appliance. Check wiring harness to all solenoids for damage and/or loose connections. Measure resistance of each solenoid valve coil.
Ensure flame rod is touching flame when unit fires. Check all wiring to flame rod for damage. Remove flame rod and check for carbon build-up; clean with sand paper. Check inside burner chamber for any foreign material blocking flame at flame rod. Measure micro amp output of sensor circuit with flame present. Replace flame rod. Flush heat exchanger. Refer to instructions in manual. Replace heat exchanger. NOTE: The LC code is the only error code that will allow the unit to keep running. The display will alternate between the LC code and the temperature setting. The controller will continue to beep. The LC code will reset if power is turned off and then on.
Clean inlet water supply filter. On new installations ensure hot and cold water lines are not reversed. Check for bleed over. Isolate unit from building by turning off hot water line to building.
Isolate the circulating system if present. Open your pressure relief valve; if water is
flowing, there is bleed over in your plumbing. Ensure you have at least the minimum flow rate required to fire unit. Ensure turbine spins freely. Measure the resistance of the water flow control sensor. Check for DC shorts at components.
14 VA Series Indoor LS Manual
Trouble Shooting for Common Issues
I don’t have any hot water when I open the tap.
Make sure there is gas, water, and electricity to the Rinnai water heater (power is turned on and the gas is turned on).
When I was using the hot water, the water got cold.
If you adjusted the flow from the tap to lessen it, you may have gone below the minimum flow required. The Rinnai water heater requires a minimum flow rate to operate. (See the specification page for the flow rate of your model.) Decrease the temperature setting at the temperature controller or increase the water flow.
White smoke comes out of the exhaust.
During colder weather when the exhaust temperature is much hotter than the outside air, the exhaust fumes condense producing water vapor.
When I open a hot tap, I do not immediately get hot water.
Hot water must travel through your plumbing from the Rinnai water heater to the faucet. The time period for hot water to reach your fixture is determined by the amount of water in the plumbing system between the water heater and the fixture, water pressure, and the flow rate of the fixture.
After I turn off the hot water tap, the fan on the Rinnai water heater continues to run.
The fan is designed to continue running for a short time after the flow of water stops. This is to ensure constant water temperatures during rapid starting and stopping, as well as exhausting any residual gas flue products from the unit.
Accessing Operating Information
Models MC-91 and MCC-91
To display the most recent error codes press and hold the “On/Off” button for 2 seconds. While holding the “On/ Off” button press the button. The last 9 error codes will flash one after the other. To exit this mode press the “On/Off” and button as before.
To display the water flow through the water heater press and hold the button for 2 seconds and without releasing the ▲ button press the “On/Off” button.
To display the outlet water temperature press and hold the button for 2 seconds and without releasing the button press the “On/Off” button.
Water Quality
Consideration of care for your water heater should include evaluation of water quality. If the water quality exceeds the target levels provided in the table, you may want to treat or condition the water.
* Source: Part 143 National Secondary Drinking Water Regulations
Total Hardness Up to 200 mg / L
Aluminum * Up to 0.2 mg / L
Chlorides * Up to 250 mg / L
Copper * Up to 1.0 mg / L
Iron * Up to 0.3 mg / L
Manganese * Up to 0.05 mg / L
Maximum Level
pH * 6.5 to 8.5
TDS (Total Dissolved Solids) *
Zinc * Up to 5 mg / L
VA Series Indoor LS Manual 15
Up to 500 mg / L
y
Flushing the Heat Exchanger (Error Code: LC or 00)
An “LC” or “00” error code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s warranty. After flushing, reset the LC fault code by turning off the power to the unit and turning the power back on.
1. Disconnect electrical power to the water heater.
2. Close the shutoff valves on both the hot water and cold water lines (V3 and V4).
3. Connect pump outlet hose (H1) to the cold water line at service valve V2.
4. Connect drain hose (H3) to service valve V1.
5. Pour approximately 4 gallons of virgin, food grade, white vinegar or citric acid into pail.
6. Place the drain hose (H3) and the hose (H2) to the pump
Rinnai
Water Heater
inlet into the cleaning solution.
7. Open both service valves (V1 and V2) on the hot water and cold water lines.
8. Operate the pump and allow the cleaning solution to circulate through the water heater for at least 45 minutes.
9. Turn off the pump.
10. Rinse the cleaning solution from the water heater as follows:
a. Remove the free end of the drain hose (H3) from the pail. b. Close service valve, (V2), and open shutoff valve, (V4).
Do not open shutoff valve, (V3).
c. Allow water to flow through the water heater for 5 minutes
n
I
n
i
e
l
­e
t
r
l
F
i
G
a
s
S
d. Close service valve, (V1), and open shutoff valve, (V3).
11. Disconnect all hoses.
12. With (V4) closed, remove the in-line filter at the cold water inlet and clean out any residue. Place filter back into unit
V1
V2
and open (V4).
13. Restore electrical power to the water heater.
H3
V4
V3
u
p
p
l
C
o
W
d
l
a
e
t
r
L
n
i
H
o
t
W
a
e
r
t
L
n
i
e
e
H2
5 gallon pail of virgin, food grade, white vinegar (or virgin,
food grade, citric acid).
Circulating Pump
KEY
3/4" Ball Valve
3/4" Union
Check Valve
Pressure Relief Valve
Pressure Regulator
Circulating Pump
Boiler Drain Valve
S
Solenoid Valve
16 VA Series Indoor LS Manual
H1
Installation Instructions
Only properly trained and qualified installers should install this appliance. The warranty may be voided due to improper installation or installation by a non­qualified installer.
Rinnai highly recommends all installers attend a product knowledge class.
For information on a Rinnai Training Course or for questions on installation call 1-800-621-9419.
R50LSi...................REU-VA2019FFUD
R75LSi...................REU-VA2528FFUD(A)
R94LSi...................REU-VA2535FFUD
R98LSi...................REU-VA3237FFU
R98LSi-ASME .......REU-VA3237FFU-ASME
General Instructions
WARNING
Do not use substitute materials.
Use only parts certified with the appliance.
This appliance must be installed by a state qualified
or licensed contractor. It is the responsibility of the person having the water heater installed to ensure the installing contractor has proper licenses and permits for installing water heaters in your location. Rinnai highly recommends that installers attend a product knowledge class to ensure customer satisfaction and warranty coverage. Failure to comply with state and local codes pertaining to water heater installations may void the warranty.
This appliance is not to be installed outdoors.
A qualified installer or service technician should
install the appliance, inspect it, and leak test it before use.
The installation must conform with local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
The appliance and its appliance main gas valve
must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa) (13.84 in W.C.).
Follow the installation instructions and those in Care and Maintenance for adequate combustion and
ventilation air.
The appliance should be located in an area where water leakage of the unit or connections will not result in damage to the area adjacent to the appliance or to lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow.
The flow of combustion and ventilation air shall not be obstructed.
This appliance is not suitable for use in an application such as a pool or spa heater that uses chemically treated water . (This appliance is suitable for filling large or whirlpool bath tubs with potable water.)
If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or local plumbing inspector on how to control thermal expansion.
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.
Keep the air intake location free of chemicals such as chlorine or bleach that produce fumes. These fumes can damage components and reduce the life of your appliance.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa) (13.84 in W.C.).
VA Series Indoor LS Manual 17
Clearances from Appliance
to top
to Combustibles
to Non-
Combustibles
Top of Heater
Back of Heater
Front of Heater
Sides of Heater
Floor/ Ground
Vent
* 4 inches (102 mm) for enclosed area; 1 inch (26 mm) for unenclosed area.
Every vent connection must be accessible for inspection, cleaning, and replacement.
The clearance for servicing is 24 inches in front of the water heater.
R50LSi R75LSi R94LSi
6 inches (152 mm)
0 (zero) 0 (zero) 0 (zero) 0 (zero)
6 inches (152 mm)
2 inches (51 mm)
12 inches (305 mm)
0 (zero) 4 inches * 0 (zero) 0 (zero)
R98LSi
12 inches (305 mm)
24 inches (610 mm)
2 inches (51 mm)
12 inches (305 mm)
R50LSi R75LSi R94LSi
2 inches (51 mm)
6 inches (152 mm)
1/2 inch (13 mm)
12 inches (305 mm)
R98LSi
2 inches (51 mm)
24 inches (610 mm)
1/2 inch (13 mm)
2 inches (51 mm)
to side
to floor/ground
to front
For closet installation: R50LSi, R75LSi, R94LSi: clearance is 6 inches (152 mm) from the front. R98LSi: clearance is 24 inches (610 mm) from the front.
Attachment of the Water Heater
1. Identify the installation location and confirm that the installation will meet all required clearances.
2. Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.
18 VA Series Indoor LS Manual
wall installation
brackets
Electrical Connection
The water heater requires a standard 3 prong 120 VAC, 60 Hz properly grounded wall outlet. Plug the 6ft long power cord into the wall outlet.
Gas Piping
General Instructions
A manual gas control valve must be placed in the gas supply line to the Rinnai water heater. A union can be used on the connection above the shut off valve for the future servicing or disconnection of the unit.
Check the type of gas and the gas inlet pressure before connecting the Rinnai water heater. If the Rinnai water heater is not of the gas type that the building is supplied with, DO NOT connect the water heater. Contact the dealer for the proper unit to match the gas type.
Check the gas supply pressure immediately upstream at a location provided by the gas company. Supplied gas pressure must be within the limits shown in the Specifications section.
Before placing the appliance in operation all joints including the heater must be checked for gas tightness by means of leak detector solution, soap and water, or an equivalent nonflammable solution, as applicable. (Since some leak test solutions,
including soap and water, may cause corrosion or stress cracking, the piping shall be rinsed with water after testing, unless it has been determined that the leak test solution is non-corrosive.)
Always use approved connectors to connect the unit to the gas line. Always purge the gas line of any debris before connection to the water heater.
The gas supply line shall be gas tight, sized, and so installed as to provide a supply of gas sufficient to meet the maximum demand of the heater and all other gas consuming appliances at the location without loss of pressure.
Any compound used on the threaded joint of the gas piping shall be a type which resists the action of liquefied petroleum gas (propane / LPG).
Refer to an approved pipe sizing chart if in doubt about the size of the gas line.
VA Series Indoor LS Manual 19
Gas Piping
Pipe Sizing Procedure - Example
The gas supply must be capable of handling the entire gas load at the location. Gas line sizing is based on gas type, the pressure drop in the system, the gas pressure supplied, and gas line type. Refer to the National Fuel Gas Code, NFPA 54, for proper gas line sizing. The below information is provided as an example.
1. Determine the cubic feet per hour of gas required by dividing the gas input (on the rating plate) by the heating value of the gas (available from the local gas company). The gas input needs to include all gas products at the location and the maximum BTU usage at full load when all gas products are in use.
Gas Input of Rinnai water heater (BTU / HR) Cubic Feet per Hour (CFH) = Heating Value of Gas (BTU / FT 3 )
2. Use the table for your gas type to find the pipe size required for your cubic feet per hour of gas and your pipe length.
Example: The heating value of propane gas for your location is 2516 BTU / FT
190,000 BTU/HR. Additional appliances at the location require 75,000 BTU/HR. Therefore the cubic feet per hour = (190,000+75,000) / 2516 = 105.3 FT If the pipe length is 100 ft then the 3/4 inch pipe size capable of supplying 197 FT
will be adequate.
3
. The gas input of the R94LSi is
3
/ HR.
3
/ HR of propane gas
Pipe Sizing Table - Natural Gas
cubic feet per hour Schedule 40 Metallic Pipe
Inlet Pressure: less than 2 psi (55 inches W.C.) Pressure Drop: 0.3 inches W.C. Specific Gravity: 0.60
Length
10
20
30
40
50
60
70
80
90
100
3/4 1 1 1/4 1 1/2
273 514 1060 1580
188 353 726 1090
151 284 583 873
129 243 499 747
114 215 442 662
104 195 400 600
95 179 368 552
89 167 343 514
83 157 322 482
79 148 304 455
Schedule 40 Metallic Pipe
Pipe Size (inches)
Pipe Sizing Table - Propane Gas
cubic feet per hour
Inlet Pressure: 11.0 inches W.C. Pressure Drop: 0.5 inches W.C. Specific Gravity: 1.50
Length
10
20
30
40
50
60
80
100
125
150
1/2 3/4 1 1 1/4
291 608 1150 2350
200 418 787 1620
160 336 632 1300
137 287 541 1110
122 255 480 985
110 231 434 892
101 212 400 821
94 197 372 763
89 185 349 716
84 175 330 677
Pipe Size (inches)
125
150
175
200
20 VA Series Indoor LS Manual
70 131 269 403
63 119 244 366
58 109 224 336
54 102 209 313
175
200
74 155 292 600
67 140 265 543
Water Piping
General Instructions
A manual water control valve must be placed in the
water inlet connection to the Rinnai water heater before it is connected to the water line. Unions may be used on both the hot and cold water lines for future servicing and disconnection of the unit.
The piping (including soldering materials) and
components connected to this appliance must be approved for use in potable water systems.
Purge the water line to remove all debris and air.
Debris will damage the Rinnai water heater.
Toxic chemicals such as those used for boiler water treatment are not to be introduced to the potable water used for space heating.
If the appliance will be used as a potable water source, it must not be connected to a system that was previously used with a nonpotable water heating appliance.
Ensure that the water filter on the Rinnai water heater is clean and installed.
Pressure Relief Valve
An approved pressure relief valve is required by the
American National Standard (ANSI Z21.10.3) / Canadian Standard (CSA 4.3) for all water heating
systems.
The relief valve must comply with the standard for
Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21.22 and /or the standard Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves, CAN1-4.4.
The relief valve must be rated up to 150 psi and to at least the maximum BTU/hr of the appliance.
The discharge from the pressure relief valve should be piped to the ground or into a drain system to prevent exposure or possible burn hazards to humans or other plant or animal life. Follow local codes. Water discharged from the relief valve could cause severe burns instantly, scalds, or death.
The pressure relief valve must be manually operated once a year to check for correct operation.
Freeze Protection
The relief valve should be added to the hot water outlet line according to the manufacturer’s instructions. DO NOT place any other type valve or shut off device between the relief valve and the water heater.
Do not plug the relief valve and do not install any reducing fittings or other restrictions in the relief line. The relief line should allow for complete drainage of the valve and the line.
If a relief valve discharges periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not plug the relief valve.
Neither Rinnai nor the American National Standard (ANSI Z21.10.3) / Canadian Standard (CSA 4.3)
requires a combination temperature and pressure relief valve for this appliance. However, local codes may require a combination temperature and pressure relief valve.
The freeze protection features include electrical heating elements and intermittent firing of the burner. Freeze protection may be disabled if electricity or gas is not supplied, or if there is an error preventing the water heater from functioning. Loss of freeze protection may result in water damage from a burst heat exchanger or water lines.
The installation of auto drain down solenoid valves is optional. However, Rinnai strongly recommends that these valves be installed to prevent damage from freezing in case the normal freeze protection should become disabled. Any product damage due to freezing will not be covered by the warranty.
VA Series Indoor LS Manual 21
In addition, the solenoid valves should be connected electrically to a surge protector with terminals. This allows the solenoid valves to operate if the water heater is disabled due to an error code.
The solenoid valves and surge protector with terminals are available for purchase at Rinnai.
Freeze Protection Piping
Vacuum
NOTICE
Breaker
Warranty does not cover damage due to freezing.
With electrical power and gas supplied to a Rinnai water heater, it will not freeze in environments as cold as -30º F when protected from direct wind exposure.
In the event of a power failure at temperatures below
Rinnai
Water Heater
freezing the water heater should be drained of all water to prevent freezing damage.
The unit may be drained manually. However, Rinnai highly recommends that drain down solenoid valves be installed that will automatically drain the unit if power is lost. Rinnai also recommends the installation of a surge protector with terminals which allows the solenoid valves to operate if the unit is disabled due to an error code.
When the electrical power to the water heater fails, the 3/4” solenoid valve closes (stopping the flow of water into the heater) and the 1/2” solenoid valve opens
a
t
c
n
C
e
o
n
3
4
/
s
G
"
(allowing the water heater and associated piping to drain. Ensure that you run the drain for the solenoids to the outside environment to prevent discharging water inside the building causing water damage).
o
i
n
NOTE:
Heat trace ALL water pipe and fittings located outside home (attic, crawl space) or building structure. (ALL water pipe and fittings shown above the dashed line in the drawing.)
NOTE:
ALL pipe and fittings shown below dashed line should be located inside home or building structure.
The vacuum breaker line should be located inside the building structure.
KEY
3/4" Ball Valve
3/4" Union
Check Valve
Pressure Relief Valve
Pressure Regulator
Circulating Pump
Boiler Drain Valve
S
Solenoid Valve
Minimum 3/4" Hot Water
Supply Line
1/2" Minimum Normally Open Solenoid Valve
This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.
G
S
3/4" Minimum Normally Closed Solenoid Valve
S
Route to Floor Drain
u
s
p
S
a
p
y
l
i
M
n
i
C
o u
S
4
/
3
m
m
u
d
l p
"
W
a
e
t
r
p
e
n
i
y
l
L
22 VA Series Indoor LS Manual
Recommended Piping for Basic Installation
Rinnai
Water Heater
Rinnai Equipment List
Rinnai Water Heaters
RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2Drain Valves and 1 Pressure Relief Valve.)
3
4
G
/
"
a
s
C
o
c
n
o
i
n
t
e
n
QTY
1
1
3/4" Ball Valve
3/4" Union
Check Valve
Pressure Relief Valve
3/4" Hot Water Supply Line
For Building Fixtures
KEY
Pressure Regulator
Circulating Pump
Boiler Drain Valve
S
Solenoid Valve
G
a
s
S
u
p
p
y
l
3
4
C
/
"
o
d
a
W
l
e
t
r
S
u
p
p
y
l
L
n
i
e
This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.
VA Series Indoor LS Manual 23
t
t
Recommended Piping for Circulation Systems
NOTE: For residential and commercial applications, this piping arrange­ment maintains full warranty.
Rinnai
Water Heater
For this application:
Pump should be controlled by an Aqua­stat, Timer or Combination Aquastat and Timer.
Pump to be sized to maintain circulation loop temperature.
The pump should be sized to overcome
he pressure loss through the tank water heater, and supply and return plumbing. Reference the Rinnai Hot Water System Design Manual, Pump Sizing for Circula -
ion.
Pump to be of bronze or stainless construction.
3
/
G
s
S
a
Minimum 3/4" Cold Water Supply Line
Tank Water Heater to be Sized for Heat Loss of Circulation Loop.
Rinnai Equipment List
Rinnai Water Heaters
RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.)
4
"
s
G
n
C
a
o
o
i
n
t
c
e
n
u
p
p
y
l
Building Supply
QTY
1
1
IMPORTANT: Connect the building return line to the hot water supply line as close as possible to the Rinnai Water Heater.
KEY
3/4" Ball Valve
3/4" Union
Check Valve
Pressure Relief Valve
Pressure Regulator
Circulating Pump
Boiler Drain Valve
S
Solenoid Valve
This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.
Electric Water
24 VA Series Indoor LS Manual
Heater
Building
Fixtures
k
n
a
T
n
o
i
s
n
a
p
x
E
Optional Piping for Circulation Systems
NOTE:
For residential and commercial
applications, this piping arrangement
reduces the warranty to the following:
3 years on heat exchanger
3 year on parts
Full warranty will be maintained if an
on-demand recirculation system in
incorporated. Refer to the Limited
Warranty.
For this application:
Pump should be controlled by an Aquastat, Timer or Combination Aquastat and Timer.
Pump to be sized to maintain circulation loop temperature.
A minimum of 3 GPM flow is recommended for the circulation system.
The pump should be sized to overcome the pressure loss through the Rinnai water heater, supply and return plumbing. Refer ­ence the Rinnai Hot Water System Design Manual, Pump Sizing for Circulation.
Pump to be of bronze or stainless construc ­tion.
Note:
Water heater outlet temperature cannot be adjusted when circulationpumpisrunning.
Rinnai
Water Heater
Rinnai Equipment List
Rinnai Water Heaters
RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2Drain Valvesand 1 Pressure Relief Valve.)
s
G
"
a
4
/
3
s
S
G
a
t
C
o
n
c
e
n
o
i
n
u
p
p
y
l
QTY
1
1
Minimum 3/4" Hot Water
Supply Line
n
B
i
g
u
d
l
i
3/4" Ball Valve
3/4" Union
Check Valve
Pressure Relief Valve
u
e
t
r
x
i
F
O
u
t
e
l
s
t
KEY
(Optional) 2-6 Gallon Storage Tank
(To eliminate cold water sandwich effect caused by frequent On/Off operation)
Pressure Regulator
Circulating Pump
Boiler Drain Valve
S
Solenoid Valve
Minimum 3/4“ Cold Water Supply Line
k
n
a
T
n
o
i
s
n
a
p
x
E
This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.
VA Series Indoor LS Manual 25
Venting Instructions
Intake / Exhaust Guidelines
Refer to the specific instructions on your vent product for additional installation requirements.
This water heater is a direct vent water heater and therefore is certified and listed with the vent system. You must use vent components that are certified and listed with the water heater model.
Do not combine vent components from different manufacturers.
The vent system must vent directly to the outside of the building and use outside air for combustion.
Every vent connection must be accessible for inspection, cleaning, and replacement.
Venting should be as direct as possible with a minimum number of pipe fittings.
Avoid dips or sags in horizontal vent runs by installing supports per the vent manufacturer’s instructions.
Support horizontal vent runs every four feet and all vertical vent runs every six feet or in accordance
Condensate
Condensate formation can occur in high efficiency direct vent appliances. To prevent condensate damage follow these instructions.
with local codes.
Vent diameter must not be reduced.
Do not connect the venting system with an existing
vent or chimney.
Do not common vent with the vent pipe of any other water heater or appliance.
Vent connections must be firmly pressed together so that the gaskets form an air tight seal.
R50LSi, R75LSi, R94LSi: The vent piece connected to the water heater must be secured with one self-tapping screw.
Refer to the instructions of the vent system manufacturer for component assembly instructions.
WARNING
If the condensate collector is not used, the drain pipe must be capped to prevent exhaust gases and condensate from entering the building. The cap is supplied on the appliance.
NOTICE
Provisions must be made to prevent the condensate from entering the water heater. Without proper drainage or disposal, condensate will damage the heat exchanger.
Vertical terminations must incorporate a condensate drain and trap as close as possible to the appliance.
Slope any horizontal venting 1/4 inch per foot (19 mm / m), towards the heater if the condensate collector is used, or towards the exhaust terminal if the condensate collector is not used.
Dispose of condensate per local codes.
The condensate trap must contain a minimum of 3
inches (75 mm) of water.
26 VA Series Indoor LS Manual
Rinnai LSi tankless water heaters have an integrated condensate collector.
Rinnai offers a condensate trap.
Regions of cold climate will create more condensate
in the vent system. The condensate collector should be used in cold climates.
Maximum Vent Length
1. Determine the number of 90 degree elbows in the vent system. (Two 45 degree elbows count as one 90 degree elbow. On the R98 models each one foot of semi rigid flex duct used in the air intake length is equivalent to one 90 degree elbow.)
2. Refer to the table to find the maximum vent length based on the number of elbows.
3. Follow the applicable note.
Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual length is
greater than 15 ft (4.6 m) then move dip switch no. 1 (SW1) to OFF.
Number of 90° Elbows
0 1 2 3 4 5 6
41 ft 1
(12.5 m)
1 If the length is greater than 21 ft (6.4 m) then move
dip switch no. 1 (SW1) to OFF.
2 If the length is greater than 15 ft (4.6 m) then move
dip switch no. 1 (SW1) to OFF.
3 If the length is greater than 9 ft (2.7 m) then move
dip switch no. 1 (SW1) to OFF.
4 Move dip switch no. 1 (SW1) to OFF.
35 ft 2
(10.7 m)
29 ft 3
(8.8 m)
23 ft 4
(7.0 m)
17 ft 4 (5.2 m)
11 ft 4 (3.4 m)
Notes 1234
5 ft 4
(1.5 m)
Switch No.
ON
O F F
1
2
3
4
5
6
7
8
NOTICE
If you have a longer vent length, dip switch no. 1 is required to be in the OFF position. This ensures the water heater will run properly. Blocked flue error codes and shutdowns may result if dip switch no. 1 is not in the correct position. On the R94LSi, the maximum water flow capacity will be reduced by about 10% when dip switch no. 1 is OFF.
VA Series Indoor LS Manual 27
Vent Products
Listed and Tested Vent Products for
R50LSi .....................REU-VA2019FFUD
R75LSi .....................REU-VA2528FFUD(A)
R94LSi .....................REU-VA2535FFUD
Manufacturer Product Parts
Rinnai/Ubbink Rolux Vent System
Heat-Fab Saf-T Vent SC system
Metal-Fab Corr/Guard Vent/Air
Intake System
Listed and Tested Vent Products for
R98LSi..................... REU-VA3237FFU
Refer to the manufacturer’s technical literature for specific part numbers and instructions.
R98LSi-ASME ......... REU-VA3237FFU-ASME
Manufacturer Product
Heat-Fab Saf-T Vent 9401AMTK 5400CI 9492 NA
Z-Flex Z-Vent 2SVSNA04.5 2SVSRCF4 2SVSTPX4 NA
Appliance
Adapter
Vertical
Termination
Horizontal
Termination
Horizontal
Concentric
Termination
Adjustable
Horizontal
Concentric
Termination
NA
NA
ProTech Systems
Metal-Fab Corr/Guard 4CGOA 4CGSWC 4CGSWMCM
* When ordering from Rinnai, ask for these part numbers or kits:
FSAAU4 - ask for FSAAU4SP (single pack)
FSRC4 - ask for FSVPK4 Variable Pitch Roof Flashing Kit (includes rain cap FSRC4, storm collar, roof jack, and roof flashing)
FSBS4 - ask for FSBS4SP (single pack)
FasNSeal FSAAU4 * FSRC4 * FSBS4 *
FSDVPTB04LH - ask for FSDVWMT04LH Kit (includes direct vent pass through FSDVPTB04LH, bird screen, exterior and interior mounting plates, appliance adapter, 3 foot flexible aluminum duct with 2 clamps, and adjustable vertical length)
FSDVPTB04LH *
FSDVWT4
4CG7HT90
4CG7HT
FSDVWMTP4LH,
FSEDVWMTP4LH
Vent Manufacturer Contact Information for Installation Instructions and Parts Lists:
Rinnai/Ubbink
Telephone: 800-621-9419 Fax: 678-829-1666 Web Site: www.rinnai.us
Heat-Fab
Telephone: 800-772-0739 Fax: 413-863-4803 E-mail: custsvc@heat-fab.com Web Site: www.heatfab.com
ProTech Systems, Inc.
Telephone: 800-766-3473 518-463-7284 Fax: 518-463-5271 E-mail: support@protechinfo.com Web Site: www.protechinfo.com
Z-Flex
Telephone: 800-654-5600 Fax: 888-889-3539 E-mail: sales@z-flex.com Web Site: www.novaflex.com
Metal-Fab Inc.
Telephone: 800-835-2830 316-943-2351 Fax: 316-943-2717 E-mail: info@mtlfab.com Web Site: www.metal-fabinc.com
NA
28 VA Series Indoor LS Manual
X
Flue Terminal Clearances (ANS Z21.10.3 CSA 4.3)
INSIDE CORNER DE TAI L
G
H
A
I
B
D
E
B
OPERABLE
FIXED CLOSED
M
K
C
FIXED
B
L
F
CLOSED
OPERABLE
B
B
J
A
AIR SUPPLY INLET
V
VENT TERMINAL
AREA WHERE
B
TERMINAL IS NOT PERMITTTED
Ref
A Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm)
B Clearance to window or door that may be opened 36 inches (91 cm) 12 inches (30 cm)
C Clearance to permanently closed window * *
Vertical clearance to ventilated soffit, located above the terminal
D
within a horizontal distance of 2 feet (61 cm) from the center line of the terminal
E Clearance to unventilated soffit * *
F Clearance to outside corner * *
G Clearance to inside corner * *
Clearance to each side of center line extended above meter/
H
regulator assembly
I Clearance to service regulator vent outlet 36 inches (91 cm) *
Clearance to nonmechanical air supply inlet to building or the
J
combustion air inlet to any other appliance
K Clearance to a mechanical air supply inlet 6 feet (1.83 m)
Clearance above paved sidewalk or paved driveway located on
L
public property
M Clearance under veranda, porch, deck, or balcony 12 inches (30 cm) 2 *
Description Canadian Installations US Installations
* *
3 feet (91 cm) within a height
15 feet (4.5 m) above the
*
meter/regulator assembly
36 inches (91 cm) 12 inches (30 cm)
3 feet (91 cm) above if within
10 feet (3 m) horizontally
7 feet (2.13 m) 1 *
1 A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves
both dwellings.
2 Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the
requirements of the gas supplier.
Clearance to opposite wall is 24 inches (60 cm) for Canada and US.
VA Series Indoor LS Manual 29
Additional Clearances - Vent Terminal
Local codes supersede these clearances.
Avoid termination locations near a dryer vent.
Avoid termination locations near commercial cooking exhaust.
For VA3237 air intake position, follow the ANS Z21.10.3 CSA 4.3 requirements on the previous page.
Vent terminal (represents concentric vent terminal or VA3237 exhaust only vent terminal)
V
(1.52 m) vertically
60"
between Rinnai terminals
(0.91 m) to ventilated or unventilated soffit or eve vent; or to a
36"
deck or porch
V
(0.30 m ) to an inside corner
(1.52 m) between Rinnai terminals at different levels
12"
VV
12"
(0.61 m) to wall or parapet
(0.30 m) between Rinnai terminals at same level
24"
V
INSIDE
CORNER
60"
V
V
12"
V V
(0.30 m) between Rinnai terminals at same level
30 VA Series Indoor LS Manual
Flue Installation - Concentric Venting (R50LSi, R75LSi, R85LSi)
Horizontal Termination without using the Condensate Collector
WARNING
If the condensate collector is not used, the drain pipe must be capped to prevent exhaust gases and condensate from entering the building. The cap is supplied on the appliance.
Maximum Height *
5 feet (1.52 m)
Horizontal Termination using
the Condensate Collector
(condensate collector must be used in all installations)
* The condensate collector must be used in horizontal terminations if a vertical rise in the vent system exceeds 5ft.
Regions of cold climate will create more condensate in the vent system. The condensate collector should be used in cold climates.
If more than one elbow is used in the vertical section the condensate collector must be used.
Vertical Termination
Condensate
Trap
3 in (75 mm) minimum
Condensate Collector
Bracket
Securing Screw
Condensate
Trap
3 in (75 mm) minimum
3 in (75 mm) minimum
3 in (75 mm) minimum
To adjust the condensate collector position or to replace the female vent top with a male vent top:
1. Loosen the 4 screws at the rear bracket
2. Slide the bracket away from the female vent top.
3. Remove the 4 screws attaching the female vent top to the water heater.
4. Lift up the female vent top and reposition as desired (or replace with a male vent top).
5. Install the 4 screws at the vent top and tighten the 4 screws at the bracket.
Secure the first vent component to the water heater with one self-tapping screw at the hole located above the condensate collector.
VA Series Indoor LS Manual 31
Flue Installation (R98LSi, R98LSi-ASME)
Air Intake Assembly
The air intake system consists of a field supplied 4 inch diameter stainless steel, Schedule 40 PVC, ABS or CPVC pipe. A maximum 6 feet of semi-rigid flexible aluminum ducting can also be used. Foil wrapped dryer vent and cell core products are not authorized.
The air intake has a zero clearance to combustibles.
Air Intake Connection
1. Drill 2 small holes at the end of the air intake pipe.
2. Slide the pipe over the air intake terminal.
3. Using a level, ensure the pipe is straight up and down.
4. With self tapping screws, attach the pipe to the air intake terminal.
5. Apply a bead of silicone around the pipe and air intake terminal, ensuring an air tight connection.
Exhaust Pipe Assembly
Refer to the manufacturer’s installation instructions for the specific exhaust vent system.
1
3
2
4
Venting Clearances to Combustibles
Enclosed Unenclosed
Vent Size
Horizontal &
Vertical
Horizontal &
Vertical
4" (102 mm) 4" (102 mm) 1" (26 mm)
Horizontal Terminations
The air intake must be located in relation to the exhaust as shown below. The air intake must angle 1/4 inch per foot to the termination to prevent entry of rain.
6
Vent
8
Optional Intake
Intake
The vent termination and air intake must be in the same pressure zone and face the same direction.
EXHAUST
COMBUSTION AIR /
INTAKE
SLOPE INTAKE AND EXHAUST
TOWARD OUTSIDE TERMINATION
MINIMUM 1/4" PER FOOT
32 VA Series Indoor LS Manual
Flue Installation (R98LSi, R98LSi-ASME)
Horizontal with Concentric Termination
SLOPE INTAKE AND EXHAUST
TOWARD OUTSIDE TERMINATION
MINIMUM 1/4" PER FOOT
Vertical Terminations
The air intake requires a return bend or two 90º elbows to prevent entry of rain.
The vent termination and air intake must be in the same pressure zone.
VA Series Indoor LS Manual 33
High Altitude Installations
Set dip switches 2 and 3 to the values shown in table below for your altitude. The default setting for the appliance is 0-2000 ft (0-610 m) with switches No. 2 and No. 3 in the OFF position.
0-2000 ft
(0-610 m)
2001-5200 ft
(610-1585 m)
WARNING
5201-7700 ft
(1585-2347 m)
DO NOT adjust the other dip switches unless specifically instructed to do so.
Switch No. 2 OFF OFF ON ON
Switch No. 3 OFF ON OFF ON
Switch No.
ON
O F F
Switch No.
ON
1
2
3
4
5
6
7
8
O F F
1
2
3
4
5
6
7
8
Switch No.
ON
O F F
1
2
3
4
5
6
7
8
7701-10200 ft
(2347-3109 m)
Switch No.
ON
O F F
1
2
3
4
5
6
7
8
Connecting Multiple Water Heaters
The EZConnect™ cable is an optional accessory that connects 2 water heaters and allows them to function as one hot water source.
The MSA-2M and MSA-2S packs are optional accessories that connect 2 to 5 water heaters and allow them to function as one hot water source.
Refer to the instructions that come with the accessory for complete installation information.
Number of Connected Water Heaters: Accessories Necessary:
2
3
Guidelines
Do not install both the EZConnect™ and the MSA packs because they are not designed to operate together.
Water heaters connected with the EZConnect™ Cable or the MSA-2M and MSA-2S packs cannot be used for the bath fill function.
Water heaters should be installed less than 18 inches apart so that the cables will reach between units and to prevent temperature fluctuations (cold water sandwich effect) when the water is shut off and turned back on.
Temperature settings can only be changed on the controller for the primary unit.
(1) EZConnect™ Cable
(1) MSA-2M
or (1) MSA-2M
and (1) MSA-2S
4
5
(1) MSA-2M
(1) MSA-2M
34 VA Series Indoor LS Manual
and (2) MSA-2S
and (3) MSA-2S
Temperature Controller Installation
Indoor models have their controller built into the front panel. A kit is available that allows the integrated controller to be removed and used as a remote controller. Additional controllers can also be installed.
Location
The controller should be out of reach of small children.
Avoid locations where the controller may become hot (near the oven or radiant heater).
Avoid locations in direct sunlight. The digital display may be difficult to read in direct sunlight.
Configurations
A maximum of 4 temperature controllers, including wired and wireless, can be installed for a water heater or bank of water heaters. Controllers can only be wired in parallel. Controllers cannot be wired in series.
The 4 temperature controllers can consist of multiple MC-91’s or MC-502RC’s but only 1 BC-100V and only 1 MC-100V.
Any one of the 5 types of controllers can be installed by itself and still operate the water heater. All functions will be available with the exception that the clock function on the BC-100V will only be available if an MC-100V is also connected.
Avoid locations where the temperature controller could be splashed with liquids.
Do not install in locations where it can be adjusted by the public.
Controllers
Wire controllers in parallel
If 4 MC-91’s are installed, simultaneously press the Priority and On/Off buttons on the fourth controller until a beep sounds.
The table to the right shows some of the possible combinations of controllers.
Cable Lengths and Size
The cable for the temperature controller should be a non-polarized two-core cable with a minimum gauge of 22 AWG. The maximum cable length from each controller to the water heater depends on the total number of wired controllers connected to the water heater.
MC-91 + MC-91 + MCC-91 MC-502RC
MC-91 + MCC-91 + MC-502RC MC-502RC
MCC-91 + MC-502RC + BC-100V MC-100V
MC-91 + MC-502RC + BC-100V MC-100V
MC-91 + MC-91 + MC-502RC BC-100V
MC-91 + MC-502RC + MC-502RC MC-100V
Number of Wired
Controllers
1 328 ft (100 m)
2 164 ft (50 m)
3 or 4 65 ft (20 m)
Maximum Cable Length for each
Controller to Water Heater
+
+
+
+
+
+
VA Series Indoor LS Manual 35
"
Temperature Controller Installation
Mounting the Controller
Follow the procedure below to install MC-91 or MCC-91 temperature controllers.
1. Determine a suitable location for the controller.
2. Make three holes in the wall as shown.
3. Run the cable between the controller and the Rinnai water heater or the controller and the other controller.
4. Remove the face plate from the temperature controller using a screwdriver.
5. Connect the cable to the temperature controller.
6. Mount the controller to the wall using the holes drilled in step 2.
7. Disconnect the power from the Rinnai water heater.
WARNING
Do not attempt to connect the temperature controllers with the power on. There is 120 volt potential, next to the temperature controller connections inside the unit.
Do not connect the temperature controller to the 120VAC terminals provided for the optional solenoid drain valves.
All service and wiring should be performed by a registered installer.
Outline of Remote
8. Remove the cover of the Rinnai water heater.
9. Remove the plastic cover from the PCB and electrical connections.
10. Thread the cable through the access hole at the base of the unit and connect the wires to the controller terminals on the right hand side bottom of the PCB.
11. Secure the controller cable using the clamp provided.
12. Replace plastic cover over PCB and then replace the cover of the Rinnai water heater.
securing screw
1-21/32"
wiring hole
3-5/16
securing screw
REMOTE CONTROL CONNECTION TERMINALS
REMOTE CONTROL CABLE
36 VA Series Indoor LS Manual
CABLE CLAMP
Operating Instructions
If you do not follow these instructions exactly, a fire or explosion
WARNING
A. This appliance does not have a pilot. It is
equipped with an ignition device which automatically lights the burner. Do not the burner by hand.
B. BEFORE OPERATING smell all around the
appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance using the ON/OFF button.
4. This appliance is equipped with an ignition device which automatically lights the burner. Do not light the burner by hand.
5. Locate the manual gas valve on the side of the heater. Turn the manual valve clockwise to the full OFF position.
FOR YOUR SAFETY READ BEFORE OPERATING
may result causing property damage, personal injury or loss of life.
try to light
OPERATING INSTRUCTIONS
try to
Manual Valve
CLOSE
OPEN
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
7. Turn the manual gas valve counterclockwise to the full ON position.
8. Turn on all electric power to the appliance using the ON/OFF button.
9. Set the thermostat to desired setting.
10. Open a hot water tap. If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier. See manual for additional information.
1. Turn off all electric power to the appliance using the ON/OFF button.
2. Set the thermostat to lowest setting.
VA Series Indoor LS Manual 37
TO TURN OFF GAS TO APPLIANCE
3. Locate the manual gas valve on the side of the heater. Turn the manual valve clockwise to the full OFF position.
)
Technical Data
Pressure Drop Curve
45
40
R98LSi R94LSi
35
30
R75LSi
25
R50LSi
20
15
Pressure Loss (psi)
10
5
0
024681012
100
90
80
70
60
50
40
30
20
10
0
Pressure Loss (ft head
Pressure Loss (ft head)
Water Flow (gpm)
Outlet Flow Data
10.0
9.0
8.0
7.0
6.0
5.0
4.0
Water Flow (gpm)
3.0
2.0
1.0
0.0
R98LSi
R94LSi
R75LSi
R50LSi
0 25 50 75 100 125 150
delta T - Temperature Rise (ºF)
38 VA Series Indoor LS Manual
Space Heating
If the water heater is to be used for both water (potable) heating and space heating then the following apply.
The piping and components connected to the water heater shall be suitable for use with potable water.
Toxic chemicals, such as used for boiler treatment, shall not be introduced into the potable water.
The water heater shall not be connected to any heating system or components previously used with a
nonpotable water heating appliance.
When the system requires water for space heating at temperatures higher than required for other uses, a means such as a mixing valve shall be installed to temper the water for other uses in order to reduce the scald hazard potential.
Space heating applications are considered commercial applications for warranty purposes.
Temperature Setting
When using this appliance to provide domestic hot water it is recommended that the domestic hot water temperature be reduced to acceptable temperatures in accordance with local codes. In the absence of local codes it is recommended that the domestic hot water temperature be set to 140º F (60º C) or lower in accordance with UPC 501.6 by using mixing valves or the temperature controller for the water heater.
Pumps
Only use pumps of brass or stainless steel construction. Do not use pumps of iron construction as they will oxidize and clog the inlet filter on the appliance.
Pumps circulating water through the water heater must be sized to overcome the pressure loss through the water heater, the heating system, and any additional plumbing pressure losses. The pressure drop curve based on the water heater model is provided in this manual.
Replacement
When replacing an existing space heating application’s water heating source (boiler, tank water heater, tankless water heater, etc.) with Rinnai water heaters, ensure that the water heaters are sized to adequately provide the necessary BTU input for the desired space heating application. Rinnai water heaters are designed to maintain a constant outlet temperature and will supply only the necessary amount of BTU’s to maintain that temperature. Depending on the application the maximum BTU rating of the unit may not be achieved. Contact Rinnai’s Applications Engineering Department for assistance at (800) 621-9419 ext. 4490.
Iron Components
Do not use Rinnai water heaters directly for space heating applications involving iron radiators or applications with any iron components. Iron components may oxidize creating rust that will clog the inlet filter of the Rinnai water heater.
VA Series Indoor LS Manual 39
A
Dimensions
R50LSi, R75LSi, R94LSi R98LSi, R98LSi-ASME
A
B
L
B
C
D
10.8600
C
D
K
H
E
F
DIM DESCRIPTION
A Width 14 (355.6) 18.5 (470)
G
I
J
E
R50LSi R75LSi R94LSi
in (mm)
H F
I
G
J
R98LSi
R98LSi-ASME
in (mm)
K
B Depth * 9.6 (244.5) 9.1 (230.5)
C Height - Unit 22.9 (582) 23.6 (600)
D Height - with brackets 25.5 (648.2) 25.2 (639.8)
E Hot Water Outlet - from wall * 3.6 (91) 4.3 (110)
F Hot Water Outlet - from center 4.3 (110) 2.4 (61)
G Cold Water Inlet - from wall * 2.8 (70) 3.7 (94)
H Cold Water Inlet - from center 1.1 (27) 2.0 (52)
I Gas Connection - from wall * 4.3 (109) 2.2 (56.2)
J Gas Connection - from center 3.5 (89) 4.3 (110)
From base to gas connection 1.6 (40) 1.6 (40)
From base to cold connection 2.0 (50) 2.0 (50)
K
From base to hot connection 1.6 (41) 1.6 (41)
* This is the minimum dimension from the wall. The wall bracket is adjustable to allow an additional 1.57 inches (40 mm).
40 VA Series Indoor LS Manual
Ladder Diagram
3A(FUSE)
HOT
FROST SENSING SWITCH
NEUTRAL
3A(FUSE)
ARRESTER
GND
VARI STOR
PG
VARI STOR
SWITCHING POWER SUPPLY
DC170V
DC12.6V
DC5V
RELAY 1
IG
DC12V
DC40V
ANTI-FROST HEATER
IGNITION
E
D
WATE R FLOW SENSOR
QS
WATE R FLOW CONTROL DE VICE
M
BY-PASS F LOW CONTROL DEVI CE
M
BY-PASS SE RV O MODEL ONLY
A
THERMAL FUSE
OVER HEAT SWITCH
OUTGOI NG WATER THERMISTOR
HEAT EXCHANGER THERMISTOR
AIR TEMPERATURE THERMISTOR
A
WATE R F LOW SENSOR CIRC U IT
A
WATE R F LO W CONTROL DE VICE CIRC U IT
A
BY-PASS FLOW CONTROL DEV ICE CIRC U IT
RELAY 1
SV0
SV1
SV2
SV3
THERMISTOR CIRCUIT
A B C
SG
SG
SG
RELAY DRIVING CIRCUI T
SOLENOID DRIVING CIRC U IT
SG
B
B
CPU
CENTRA L PROCESSING UNIT
SG
SG
A BC
MODULATING VALVE POWER CONTROL CIRC U IT
SG
D
FAN CONTROL CIRCUIT
PG
A
FLAME DETECTING CIRCUIT
SG
A B
REMOTE CONTROLLER CIRCUIT
SG
GND
E
MODULATING SOLENOID VALVE
POV
COMBUSTION FAN
FAN
FLAME ROD
FR
REMOTE CONTROLLER
INDOOR MODEL ONLY
SG
VA Series Indoor LS Manual 41
Consumer Support
Warranty Information
The installer is responsible for your water heater’s correct installation.
Please complete the information below to keep for your records:
Purchased from: _________________________________________________________________
Address: _____________________________ Phone: _________________________________
_____________________________
Date of Purchase: __________________________________
Model No.: ________________________________________
Serial No.: ________________________________________
Installed by: ___________________________ Installer’s License No.: _____________________
Address: _____________________________ Phone: _________________________________
Date of Installation: __________________________________
Limited Warranty
What is covered?
This Warranty covers any defects in materials or workmanship when the product is installed and operated according to Rinnai written installation instructions, subject to the terms within this Limited Warranty document. This Warranty applies only to products that are installed per local and/or state codes. Improper installation may void this Warranty. Rinnai strongly suggests that you use a state qualified or licensed installer who has attended a Rinnai product knowledge class before installing this water heater. This Warranty extends to the original purchaser and subsequent owners, but only while the product remains at the site of the original installation. This Warranty only extends through the first installation of the product and terminates if the product is moved or reinstalled at a new location.
How long does coverage last?
VA LS Series Period of Coverage (from date of purchase)
Item
Residential Applications
Heat Exchanger 12 years * 10 years * † 5 years *
All Other Parts and Components 5 years * 5 years * † 5 years *
Reasonable Labor 1 year
* Note: Period of coverage is reduced to 3 years from date of purchase when used as a circulating water heater within a hot
water circulation loop, where the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an on-demand recirculation system is not incorporated.
On-demand recirculation is defined as a hot water recirculating loop or system that utilizes existing hot and cold lines
or a dedicated return line, and only activates when hot water is used. It can be activated by a push button, motion sensor, or voice activation but not by a temperature sensor. A timer added to a standard recirculating pump is not considered as on-demand.
There is no warranty coverage on product installed in a closed loop application, commonly associated with space
heating only applications.
Use of an MCC-91 controller in a residential dwelling will reduce the warranty coverage to that of a commercial
warranty application (except when an MCC-91 is used with a Rinnai Hydronic Air Handler).
The integrated controller on indoor models has a 1 year warranty on parts.
† Note: Period of coverage is reduced to 3 years from date of purchase if the Rinnai water heater temperature setting
exceeds 160º F (71º C).
Used with Rinnai Air Handler
for domestic heating and water
Commercial Applications
including radiant heating
42 VA Series Indoor LS Manual
Limited Warranty Continued
What will Rinnai do?
Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or component. All repair parts must be genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that is properly trained, state qualified or licensed to do the type of repair.
Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of the product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product at Rinnai’s discretion. If a component or product returned to Rinnai is found to be free of defects in material or workmanship, or damaged by improper installation or damaged during return shipping, the warranty claim for product, parts and labor may be denied.
How do I get service?
You must contact a state qualified/licensed contractor or authorized service provider for the repair of a product under this Warranty. For the name of a qualified/authorized service provider please contact your place of purchase, visit the Rinnai website (www.foreverhotwater.com City, Georgia 30269.
Proof of purchase is required to obtain warranty service. You may show proof of purchase with a dated sales receipt, or by registering within 30 days of purchasing the product. To register your tankless water heater, please visit www.rinnairegistration.com by Rinnai will constitute proof-of-purchase for this product. However, Registration is not necessary in order to validate this Warranty.
What is not covered?
This Warranty does not cover any failures or operating difficulties due to the following:
. For those without internet access, please call 1-866-RINNAI1 (746-6241). Receipt of Registration
), call Rinnai at 1-800-621-9419 or write to Rinnai at 103 International Drive, Peachtree
accident, abuse, or misuse
alteration
misapplication
force majeure
improper installation (such as but not limited to inadequate water quality, condensate damage, improper venting, incorrect
gas type, incorrect gas or water pressure, or absence of a drain pan under the appliance)
improper maintenance (such as but not limited to scale build-up, freeze damage, or vent blockage)
incorrect sizing
any other causes other than defects in materials or workmanship
This Warranty does not apply to any product whose serial number or manufacture date has been defaced. This Warranty does not cover any product used in an application that uses chemically treated water such as a pool or spa heater. This appliance is suitable for filling large or whirlpool bath tubs with potable water. Refer to the Water Quality Section in the Operation and Installation Manual.
Limitation on warranties
No one is authorized to make any other warranties on behalf of Rinnai America Corporation. Except as expressly provided herein, there are no other warranties, expressed or implied, including, but not limited to warranties of merchantability or fitness for a particular purpose, which extend beyond the description of the warranty herein and further Rinnai shall not be liable for indirect, incidental, special, consequential or other similar damages that may arise, including lost profits, damage to person or property, loss of use, inconvenience, or liability arising from improper installation, service or use. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
Any implied warranties of merchantability and fitness arising under state law are limited in duration to the period of coverage provided by this limited Warranty, unless the period provided by state law is less. Some states do not allow limitations on how long an implied Warranty lasts, so the above limitation may not apply to you.
This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
VA Series Indoor LS Manual 43
Rinnai’s other fine products
Tankless Water Heaters
• Residential and Commercial Applications
• Continuous Hot Water
• Up to 9.8 GPM
• High Energy Efficiency
• Propane or Natural Gas
• Internal or External Installation
• Digital Temperature Control
• Small, Compact Design
Direct Vent Furnaces
• High Efficiency
• Cool-to-the-touch Cabinet
• Blower Included
• Vent Terminal A Included
• 556 and 1004 Models Available in Beige, White and Silver
• Gas Conversion Kit Included
Rinnai America Corporation
103 International Drive
Peachtree City, GA 30269
TOLL FREE: 1-800-621-9419
FAX: 678-829-1666
www.rinnai.us
© 2008 Rinnai America Corporation
Direct-Vent Fireplace, RHFE-750ETR
• Up to 83% AFUE Energy Efficiency
• Zero-Clearance Installation
• Available in Four Options of Fronts
• Remotes and Fan Included
• Gas Conversion Kit Available
Hydronic Air Handler
Designed for Use with Rinnai Systems
Domestic Hot Water Priority
Optional Programmable Thermostat
Zero Clearance to Combustibles
Accommodates Standard Cased-Coils
Register your product at www.rinnairegistration.com or call 1-866-RINNAI1 (746-6241)
Jun / 2008