Rinnai Q175S, Q205S User Manual

Q175S / Q205S Condensing Boiler
Standard Features
Onboard outdoor reset control system with sensor standard
Priority DHW standard (3 way valve not included)
Domestic hot water plate warming
Modulating Ceramic premix burner
5:1 turn down ratio
Spark ignition
Exceeds SCAQMD 1146.2 Low NO
Stainless Steel Water tube condensing heat exchanger
Direct Vent sealed combustion
Concentric and twin pipe venting adapters included
Approved for room and closet installations
requirements
x
SPECIFICATIONS
General Specifications
Boiler
Water content gal 1.8 1.8 Max. supply boiler
temperature Max operating pressure psi 45 45 Relief valve rating MBH 375 375 Relief valve pressure rating psi 30 30
Units
°F 176 176
Model
Q175S Q205S
Boiler
Model
Optional Accessories
3 way valve DHW kit
RS100 Single zone controller
Flue Gas temperature sensor
Room Air Filter
NG to LP conversion Kit
LP to NG Conversion Kit
Performance Specifications
Units
Fuel Type NG/LP NG/LP Input MBH 175 205 Heating Capacity MBH 161 189 AFUE (I=B=R) % 95.7 95.7 Part Load Efficiency
(EN677)
% 98.5 98.5
Boiler Model
Q175S Q205S
Dry weight lbs 141 141
Electrical Specifications
Min inlet gas pressure NG "W.C. 4.0" 4.0" Max inlet gas pressure NG "W.C. 10.5" 10.5" Min inlet gas pressure LP "W.C. 8.0" 8.0" Max inlet gas pressure LP "W.C. 14.0” 14.0” Max equivalent exhaust
vent length Max equivalent combustion
air vent length
Approved venting materials
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
© 2011 Rinnai Corporation
ft 80 40
ft 80 40
Polypropylene,
Stainless Steel,
PVC, CPVC
Units
Electrical Voltage Mains V/Hz 120/60 120/60 Electrical Voltage Controls V 24 24 Power Consumption Max
Load Power Consumption Stand
by Load Recommended Circuit
breaker rating
Q175S / Q205S SP 2/2011
W 210 234
W 14 14
A 15 15
Boiler Model
Q175S Q205S
DIMENSIONS
Q175S / Q205S
A Height 26.8 / 680 B Width 26 / 660 C Depth 15.2 / 385 D Left side / vent 19.5 / 495
Center to center / vent and air
E
supply F Back / vent 10.6 / 270 G Left side / gas pipe 2.6 / 65 H Left side / supply pipe 7.3 / 185 J Left side / return pipe 17.5 / 445 K Left side / condensate pipe 20.9 / 530 P Pipe length of g 0.7 / 18 Q Pipe length of c 2 / 50 R Pipe length of e, f, k, r, and w 2.3 / 60 S Back / center of pipe c 1 / 25 T Back / Center of pipe g 1.6 / 40
Q175S, Q205S
inch / mm
4.7 / 120
2.0”
50mm
2.1”
54mm
[5.6”
142mm
18.6”
474mm
4.7”
120mm
5.2”
133mm
15”
381mm
17.2”
438mm
10.2”
260mm
12”
305mm
19.7”
501mm
Back, / center of pipe e, f, k, r,
U
and w
Pipe length vent co-axial
V
Pipe length vent parallel
Clearances
Minimum required
Top 2 / 50 10 / 250 Back 0 0 Front 6 / 150 24 / 600 Left side 2 / 50 2 / 50 Right
side Floor /
Ground Vent 0 0
clearance to combustibles and non-combustibles
2 / 50
2.6 / 65
5.8 / 147
Recom­mended
service
clearances
inch / mm
2 / 50 2 / 50
12 / 300 30 / 762
inch / mm
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us