Rinnai Performance Chart Miscellaneous Information

8.5” 7.25” 5.5”
Performance Chart
FOR TANKLESS RACK SYSTEMS UTILIZING STORAGE
Rack System Configurations 60° Temperature Rise 70° Temperature Rise 80° Temperature Rise 90° Temperature Rise 100° Temperature Rise
Number of
TWH
2
3
4
5
6 TRS06 1,194,000
7 ** 1,393,000
8 ** 1,592,000
9 ** 1,791,000
10 ** 1,990,000
11 ** 2,189,000
12 ** 2,388,000
Model**
TRW02/
TRS02
TRW03/
TRS03
TRW04/
TRS04
(TRW02 +
TRW03)
TRS05
BTUH Input
398,000
597,000
796,000
995,000
WH Max
Recovery Capacity and First Hour Delivered @ Temperature rise (°F) with Storage Tank
Recovery Pump Size
Tank Size
GPM Head (ft)
100
200 896 788 707
300 966 858 777
100
200 1,274 1,112 991
300 1,344 1,182 1,061
400 1,414 1,252 1,131
100
200 1,652 1,436 1,274
300 1,722 1,506 1,344
400 1,792 1,576 1,414
500 1,862 1,646 1,484
200
300 1,722 1,506 1,628
400 1,792 1,576 1,698
500 1,862 1,646 1,768
200
300 2,479 2,155 1,911
400 2,549 2,225 1,981
500 2,619 2,295 2,051
300
400 2,927 2,549 2,265
500 2,997 2,619 2,335
300
400 3,305 2,873 2,549
500 3,375 2,943 2,619
300
400 3,683 3,197 2,832
500 3,753 3,267 2,902
400
500 4,131 3,591 3,186
400
500 4,509 3,915 3,469
400
500 4,887 4,239 3,753
12 30 95% 12.6 756
18 30 95% 18.9 1,134
24 30 95% 25.2 1,512
30 30 95% 25.2 1,512
36 30 95% 37.8 2,269
42 30 95% 44.1 2,647
48 30 95% 50.4 3,025
54 30 95% 56.7 3,403
60 30 95% 63.0 3,781
66
72 30 95% 75.6 4,537
30 95% 69.3 4,159
Recovery
Efficiency
Recovery
GPM
Recovery
GPH
First Hour Delivered
826
1,204
1,582
1,652
2,409
2,857
3,235
3,613
4,061
4,439
4,817
Recovery
GPM
10.8 648
16.2 972
21.6 1,296
27.0 1,296
32.4 1,945
37.8 2,269
43.2 2,593
48.6 2,917
54.0 3,241
59.4 3,565
64.8 3,889
Recovery
GPH
First Hour Delivered
718
1,042
1,366
1,436
2,085
2,479
2,803
3,127
3,521
3,845
4,169
Recovery
GPM
9.5 567
14.2 851
18.9 1,134
23.6 1,418
28.4 1,701
33.1 1,985
37.8 2,269
42.5 2,552
47.3 2,836
52.0 3,119
56.7 3,403
Recovery
GPH
First Hour Delivered
637
921
1,204
1,558
1,841
2,195
2,479
2,762
3,116
3,399
3,683
Recovery
GPM
8.4 504
12.6 756
16.8 1,008
21.0 1,260
25.2 1,512
29.4 1,764
33.6 2,017
37.8 2,269
42.0 2,521
46.2 2,773
50.4 3,025
First Hour Delivered
Recovery
GPM
574
644 594
714 664
826
896 821
966 891
1,036 961
1,078
1,148 1,047
1,218 1,117
1,288 1,187
1,358 1,257
1,400
1,470 1,344
1,540 1,414
1,610 1,484
1,652
1,722 1,571
1,792 1,641
1,862 1,711
1,974
2,044 1,868
2,114 1,938
2,227
2,297 2,095
2,367 2,165
2,479
2,549 2,322
2,619 2,392
2,801
2,871 2,619
3,053
3,123 2,845
3,305
3,375 3,072
Recovery
GPM
7.6 454
11.3 681
15.1 907
18.9 1,134
22.7 1,361
26.5 1,588
30.2 1,815
34.0 2,042
37.8 2,269
41.6 2,495
45.4
Recovery
GPH
2,722 3,002
First Hour Delivered
1,274
1,501
1,798
2,025
2,252
2,549
2,775
524
751
977
Cross Reference for Existing or
Specified Systems
Existing System
Existing
or Specified Systems
BTUH
400,000
600,000
800,000
1,000,000
1,200,000
1,400,000
1,600,000
1,800,000
2,000,000
2,200,000
2,400,000
Storage
Tank
Size
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
As specied
or existing
Existing or
Specified TE
≥ 93%
≥ 93%
≥ 93%
≥ 93%
≥ 93%
≥ 93%
≥ 93%
≥ 93%
≥ 93%
≥ 93%
≥ 93%
DEFINITIONS:
Tank capacity: capacity of water in gallons inside storage tank as stated by manufacturer
Recovery pump: pump that will circulate water from tank to TRS during recovery period
Recovery flow rate: flow rate in gpm at which volume inside tank is being recovered
Recovery GPH: the water heater’s ability to replenish hot water as it’s drawn from the tank
Recovery efficiency: the ratio of energy delivered to the water to the energy content of the fuel consumed by the water heater
First Hour Delivered (Gal): useable volume of water that can be drawn in one hour and is determined using the following formula
First Hour Delivered (Gal) = Recovery GPH +Tank capacity x 0.70
Temperature rise: temperature difference in °F between the TRS set point and the incoming water temperature
Note: This chart should be used only when the existing or specified system is known. Select TRS model to the left of chart. Use existing or specified storage tank with TRS selection. Reference chart to left for recovery GPH performance. To calculate “First Hour Delivered” add 70% of existing or specified tank volume to recovery GPH.
** Note: Multiple congurations available. TRS models are Free-Standing units;
TRW models are Wall-Mount units.Reference TRS Manual and Specication.
If common venting is used with the TRS, please contact Rinnai for assistance.
How to Select a TRS System Using TRS Performance
8.5”7.25”5.5”
Chart (Recovery GPH / First Hour Delivered Required):
Find value closest to specified recovery GPH or first hour delivered at temperature rise. Select corresponding TRS system, storage tank and recovery pump size to the left of the table.
For example: If specified First hour delivered is 900 gallons @60° F rise, select TRS system corresponding to 896 gallons:
TRS System: TRS02 or TRW02 Storage tank size: 200 gallons Recovery pump size: 12 GPM @30 ft head
How to Select a TRS System Using TRS Cross Reference Chart:
Find existing or specified system BTUH and thermal Eff (TE) to the left of chart, match closely to TRS system BTUH and select TRS System with recovery pump accordingly.
For example: If existing or specified system BTUH is 400,000 and thermal Eff 93%
TRS System: TRS02 or TRW02 Storage tank size: as specified or existing Recovery pump size: 12 GPM @ 30 ft head
Product Sizing Disclaimers
This Sizing Reference Guide and all information contained herein is based on the proper installation and use of (1) a series of Rinnai Tankless Water Heaters which are piped to a storage tank and (2) an adequate and properly-sized Recovery Pump that will recover the storage tank (i.e., that will circulate water from the Rinnai Tankless Water Heaters into the storage tank) thereby allowing the Rinnai Tankless Water Heaters to properly heat the water for the storage tank.
This Sizing Reference Guide is intended to be used as a guide only and not as a replacement for a professionally-engineered project. The guide should only be referenced after your design criteria has been selected and approved by your design engineer and/or contractor. The guide is intended to assist the user in determining the model type and number of products that can be utilized for a particular application. The information set forth herein is for general assistance and information only and should not be the sole factor in making any decision about a specific system or product.
For additional information, please refer to the Rinnai Hot Water System Design Manual or contact the Application Engineering Department at Rinnai America Corporation.
Sizing Reference Guide
FOR TANKLESS RACK SYSTEMS UTILIZING STORAGE
A tradition of
For nearly 100 years, we at Rinnai have been ercely committed to
delivering nothing less than our absolute best at every touch point.
To us, that means more than manufacturing products—it’s about
inspiring condence in our customers. Condence in the comfort
our solutions give. And in the support we provide.
TRUE RELIABILITY.
The information set forth herein regarding performance of a TRS/Storage tank system does not, and is not intended to imply, warrant, or represent that a specific system is adequate or appropriate for your given application.
The sizing information set forth herein does not describe a complete system. Anyone using this Sizing Reference Guide is ultimately responsible for determining the actual hot water demand for the specific application and for selecting appropriate Rinnai products for the given application.
Your design engineer and/or contractor must determine the necessary components for and configuration of the particular system being installed. All such design conditions must be met. The information contained herein does not imply compliance with local building codes. It is the responsibility of your design engineer and/or contractor to ensure that installation of any system is performed in accordance with all applicable building codes. You should always confer with local building officials before installation.
An adequate and properly-sized Recovery Pump is critical to the proper performance and operation of the systems described herein. Indeed, the systems described herein will only work with an adequate and properly-sized Recovery Pump.
Ensure that all water supply pipes are sized per local plumbing codes.
Multiple TRS should be installed in parallel using a secondary manifold from the building’s cold and hot water supply. You should reference the particular section of the TRS installation manual for piping multiple racks.
The building’s circulation pump must be controlled by an aquastat, timer, or both.
The Recovery Pump must be controlled by a submersible aquastat placed inside the tank. A minimum 20°F differential temperature setting is required for the aquastat. For example, if the Rinnai set point is 140°F, then the aquastat activation set point should be 120°F.
Always refer to the storage tank and aquastat manufacturer installation instructions for additional information.
Only use pumps of brass, bronze, or stainless steel construction. Do not use pumps of iron construction.
If the intended installation of a system is located in a hard water area, a softener or similar water treatment system must be used.
Learn more about our high-performance Tankless Water Heaters,
Boilers and Direct Vent Wall Furnaces at www.rinnai.us
Rinnai America Corporation • 103 International Drive, Peachtree City, GA 30269
Toll-Free: 1-800-621-9419 • Phone: 678-829-1700 • www.rinnai.us
©2013 Rinnai America Corporation. Rinnai is continually updating and improving products; therefore, specications are subject
R-PRWH-E-25 08/2013
to change without prior notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation.
FOR TRADE PROFESSIONALS
Loading...