Rinnai ORH15S, ORH24L, ORH18M, ORH32XL Operation & Installation Manual

Page 1
This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000 Electrical Installation (Wiring Rules)
• Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed and maintained in
Operation & Installation Manual
Outdoor Radiant Heater
Models: ORH15S / ORH18M / ORH24L / ORH32XL
Page 2
Rinnai 2 ORH OIM
This page is intentionally blank
Page 3
Rinnai 3 ORH OIM
TABLE OF CONTENTS
Warnings and Important Information 4
About Your Outdoor Radiant Heater 6
Radiant Heating Principles ��������������������������������������������������������������������������������������������������������������������������������� 6
Features ������������������������������������������������������������������������������������������������������������������������������������������������������������� 6
Specications  ����������������������������������������������������������������������������������������������������������������������������������������������������� 6
General Design Layout / Carton Contents ��������������������������������������������������������������������������������������������������������� 7
Operation ������������������������������������������������������������������������������������������������������������������������������������������������������������ 7
Installation 8
Regulatory Requirements ����������������������������������������������������������������������������������������������������������������������������������� 8
Unpacking ���������������������������������������������������������������������������������������������������������������������������������������������������������� 8
Approximate Heating Area ���������������������������������������������������������������������������������������������������������������������������������8
Outdoor Radiant Heater Mounting ��������������������������������������������������������������������������������������������������������������������� 8
Clearances ��������������������������������������������������������������������������������������������������������������������������������������������������������� 9
Installation Method ������������������������������������������������������������������������������������������������������������������������������������������� 10
Electrical connections ��������������������������������������������������������������������������������������������������������������������������������������� 11
Location of Electrical Connection ��������������������������������������������������������������������������������������������������������������������� 11
Multiple Installations ����������������������������������������������������������������������������������������������������������������������������������������� 11
Care & Maintenance 12
Cleaning ����������������������������������������������������������������������������������������������������������������������������������������������������������� 12
Save A Service Call ������������������������������������������������������������������������������������������������������������������������������������������ 12
When to Call for Service ����������������������������������������������������������������������������������������������������������������������������������� 12
Warranty 13
Contacts 16
Page 4
Rinnai 4 ORH OIM
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and to ensure optimum
performance. When using an outdoor radiant heater, it is necessary to observe specic precautions. 
Failure to carefully read and follow all instructions and precautions in this manual can result in equipment malfunction, property damage, personal injury and/or death�
Use this appliance only as described in this manual� Any other use is not recommended by the
manufacturer and may cause re, electric shock or injury.
WARNINGS: WHEN IGNORED, CAN RESULT IN SERIOUS INJURY OR DEATH.
CAUTIONS: WHEN IGNORED, CAN RESULT IN MINOR INJURY OR PRODUCT DAMAGE.
WARNING
It is important that the following precautions are followed to minimise the risk of overheating, re, electric 
shock and injury:
The appliance MUST BE installed at least 2.1m above the oor.
Handle the appliance with care, avoid vibrations and knocks� Unpack the appliance and check for damage� DO NOT INSTALL A DAMAGED APPLIANCE� If the appliance is damaged or defective, contact your supplier for advice, the appliance may ONLY be serviced by the manufacturer or the manufacturer’s
agent or similarly qualied person.
DO NOT install or use the appliance if the power cord is damaged� If it is damaged or requires replacing,
it must be replaced by the manufacturer or the manufacturer’s agent or similarly qualied person.
Ensure that the voltage and frequency of the power supply correspond to the ratings on the data plate of the appliance�
Models ORH15S, ORH18M and ORH24L are tted with an Australian exible 1m cord and 3 pin plug. A 
dedicated 240V 50Hz earthed 10 Amp power point must be used with this appliance�
Model ORH32XL are tted with an Australian exible 1m cord and  3 pin plug. A dedicated  240V 50Hz 
earthed 15 Amp power point must be used with this appliance�
DO NOT use power boards or double adaptors for this appliance�
This appliance MUST NOT be located immediately below or directly in front of a power point / electrical connection� The power point / electrical connection is to be within 1m of the appliance, yet should be located outside the physical footprint of the unit to prevent exposure to heat build-up behind the appliance�
If the heater is to be mounted on an incline such as a vaulted ceiling, ensure the power point / electrical connection is located at that lowest point of the appliance (see page 11 for details)�
The appliance may be direct wired ONLY by a licensed electrical trades person in accordance with local regulations�
The appliance should be connected to an electric circuit equipped with an automatic circuit breaker�
DO NOT connect the  appliance to  the mains power  until it has been  installed  in its nal  location  and 
adjusted to the position it will be used in�
The installation MUST BE equipped with an all-pole disconnection mechanism in accordance with wiring rules�
The electrical cord MUST NOT come into contact with the heated parts of the appliance� DO NOT unplug
the appliance by pulling on the exible cord.
DO NOT coil or bundle the electric cord to reduce its length as overheating of the cord may occur which
could result in a re hazard.
Use of an extension cord on this appliance is not recommended� The appliance is NOT intended to be used as a portable heater�
IMPORTANT
WARNINGS AND IMPORTANT INFORMATION
Page 5
Rinnai 5 ORH OIM
WARNING
This appliance MUST NOT be installed where curtains or other combustible materials could come into contact or in close proximity with it� In some cases curtains may need restraining�
When installed outdoors this appliance is suitable for under cover use ONLY�
DO NOT place articles or on or against this appliance�
DO NOT place any items of clothing, hand towels or similar over the appliance to dry�
DO NOT spray aerosols in the vicinity of this appliance whilst the appliance is operating� Most aerosols
contain ammable gas, which can be a re hazard if used near the appliance when it is in use.
DO NOT use or store ammable materials, liquids, etc. near this appliance. Combustible materials must 
not be placed where the appliance could ignite them�
DO NOT use the appliance in areas where the presence of ammable dust particulates may cause an 
explosion�
Do not use the appliance, in a green house, barn or stable or on a on a building site or where ammable 
dust may be present�
DO NOT use this appliance in the place of animal propagating areas�
DO NOT use the appliance as a sauna heater�
DO NOT leave the appliance unattended whilst in operation�
CAUTION when being operated the surfaces of this appliance will get VERY HOT - DO NOT TOUCH ANY PART OF THE APPLIANCE WHILE IT IS TURNED ON� To avoid burns, DO NOT touch the any
surface of the appliance with any body part� The appliance must be located in a position that prevents contact by any person (including accidental)�
The appliance will retain signicant heat for a period after shut down. To avoid burns, DO NOT touch the any surface of the appliance with any body part during this period�
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety and have the capacity to follow those instructions�
The appliance is not intended for use by young children or inrm persons without supervision.
Young Children must be supervised when in the vicinity of this appliance while it is in operation�
This appliance is NOT equipped with a device to control the room temperature� DO NOT use this appliance in small rooms (see “Approximate Heating Area” on page 8) when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided�
DO NOT allow young children or the inrm to remain unsupervised or sleep directly in front of or below 
the appliance while in operation�
NO USER SERVICEABLE PARTS - NEVER dismantle the appliance� Tampering with electrical connections and components is highly dangerous and can result in equipment malfunction, property damage, personal injury and/or death�
DO NOT modify this appliance. Modifying from original specications may create a dangerous situation 
and will void your warranty�
WARNINGS AND IMPORTANT INFORMATION
Page 6
Rinnai 6 ORH OIM
RADIANT HEATING PRINCIPLES
Radiant heat is widely regarded as the most comfortable, healthiest and most natural form of outdoor heating available. This heating type is based on the same primary source of heat we know - the warmth of the sun. It warms you and the objects around you instead of the air.
The warmth felt from the sun is not warm air but infra-red energy. Like the sun, radiant energy from the heater moves in straight lines, directly warming the people and objects in its path which in turn acts as small heat convectors, giving off their own gentle heat to enhance people feeling warm.
This radiant heating principle is common to all 4 models, regardless of the wattage of the heater. As the wattage and product length increases the heating footprint will be greater.
FEATURES
This outdoor radiant heater uses electricity as the heating medium. It operates on the infrared radiant heating principle directly warming people and objects in the area instead of the air within it.
Ease of Installation & Operation
Suitably sized 3 pin plugs are provided to allow for ease of installation to a wall socket. It is designed to be plugged into a circuit that has an operating isolation switch within reach of the user which enables the heater to be switched on or off.
Silent Operation
Electric element operation eliminates fan noise.
Draft Free
Non fan operation also means no drafts.
IP65
Water ingress protection allows for
safe cleaning of the external heater casing using a typical low pressure
garden hose or by using a wet sponge.
SPECIFICATIONS
Model; ORH15S ORH18M ORH24L ORH32XL
Max. rated power 1500W 1800W 2400W 3200W
Rated voltage 240V 50Hz
Three pin plug type 10 Amp 15 Amp
Length of power lead (mm) 1000
IP Rating IP65
Heater Body
Dimensions
(mm)
Length 1030 1210 1490 1900
Width 160
Height 50
Unit Weight (kg) 4.8 5.4 6.5 8.2
Available installation options Ceiling and Wall mount
Recommended
mounting heights (mm)
From
Min. / Max. * 2100 / 3000
Ideal. 2100 - 2700
Clearances
Vertically from a surface Min. 1000
Other
See "Clearances" on page 9 for requirements
* Heating effectiveness will be reduced if appliance is mounted at greater heights.
L H
W
ABOUT YOUR OUTDOOR RADIANT HEATER
Page 7
Rinnai 7 ORH OIM
GENERAL DESIGN LAYOUT / CARTON CONTENTS
The packaging for this appliance should contain:
1. Outdoor Radiant Heater: a. Heater body b. Front radiating surface.
2. 1000mm Flexible power cord with three pin plug
3. Operation Indicator Light
4. Adjustable angle mounting bracket (x2)
5. Mounting bracket locking plates (x2)
6. Operating & Installation Instructions
OPERATION
1. Before operating the heater for the
time or after periods of non use ensure that the radiating surface is
clean and free of debris or dust see "Cleaning" on page 12.
2. Ensure that the GPO for the heater is in the "ON" position, then switch "ON" the power at the isolating switch (if
3. The orange operation indicator will light to indicate the heater is on and the heater will begin to radiate infrared heat.
NOTE
The heater may take up to 15 minutes to reach maximum heat, depending on the area being heated and the conditions.
4. Switch "OFF" the power at the isolating switch to turn off the heater. The operation indicator will go out.
NOTE
The heater may take up to 30 minutes to fully cool down, depending on the area being heated and the conditions.
4
5
1b
2
3
5
6
1a
4
ABOUT YOUR OUTDOOR RADIANT HEATER
Page 8
Rinnai 8 ORH OIM
REGULATORY REQUIREMENTS
The heater must be installed in accordance with the manufacturers installation instructions�
The heater MUST ONLY be installed or removed by an authorised person�
The heater MUST be installed in accordance with AS/NZS 3000 and all other applicable local municipal building codes including OH&S requirements
UNPACKING
IMPORTANT
If any damage is present DO NOT INSTALL or OPERATE the appliance and contact your supplier for advice.
APPROXIMATE HEATING AREA
A
B
C
Heater
Indoor Area Spot Heating
Dimension ORH15S ORH18M ORH24L ORH32XL
A 1030 1210 1490 1900
B 1700 2050 2650 3550
C 2150 2150 2150 2150
Outdoor Covered / Enclosed Area
Dimension ORH15S ORH18M ORH24L ORH32XL
A 1030 1210 1490 1900
B 1400 1600 2050 2750
C 2150 2150 2150 2150
OUTDOOR RADIANT HEATER MOUNTING
This outdoor radiant heater comes with a pair of stainless steel adjustable angle mounting brackets� The adjustable angle enables the heater to be installed on vertical, horizontal and inclined surfaces�
The ideal mounting position is directly above the area to be heated with a longitudinal orientation and facing vertically downwards� If this is not possible, the heater(s) can be mounted on a wall and angled downwards� For this application ensure the mounting height is within 2�1m to 2�7m�
WARNING
The heater must never be installed in the upwards or inwards facing position, the heating surface must always be positioned to direct the heat in a downwards or outwards direction.
Vertical wall mount
Inclined ceiling mount
Horizontal ceiling mount
Angled horizontal ceiling mount
Correct Installation
Incorrect Installation
WALL
WALL
WALL
WALL
CEILINGCEILINGCEILINGCEILING
INSTALLATION
Page 9
Rinnai 9 ORH OIM
CLEARANCES
Minimum clearances when mounting the heater on A VERTICAL WALL.
Minimum clearances when mounting the heater parallel with A CEILING.
Minimum clearances when mounting the heater at an ANGLE TO A CEILING.
1500 Min.
100 Min.
220 Min.
1000 Min. to surfaces (ie table tops, ect) 2100 Min. from floor 3000 Max. from floor (recommended)
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
Same both ends
600 Min.
600 Min600 Min
175 Min
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
Same both ends
600 Min.
1000 Min. to surfaces (ie table tops, ect) 2100 Min. from floor 3000 Max. from floor (recommended)
1500 Min.
600 Min.
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
125 Min.
Same both ends
600 Min.
1000 Min. to surfaces (ie table tops, ect) 2100 Min. from floor 3000 Max. from floor (recommended)
INSTALLATION
Page 10
Rinnai 10 ORH OIM
INSTALLATION METHOD
1. Open the packaging and carefully take the heater out and inspect for any damage.
2. Determine the mounting position for the heater, refer to "Approximate Heating Area" on page 8 "Outdoor Radiant Heater Mounting" on page 8 and 9 to assist with the location of the heater.
3. Set the adjustable angle mounting brackets (2.) to desired angle:
For ceiling mounted installations the available mount angles are restricted to 0°, 15° and 30° only.
For wall mounted installations the available mount angles are restricted to 15°, 30° and 45° only.
4. Mark the position of the two brackets, using the following minimum recommended bracket spacing below to determine the correct location.
Dimension (mm) ORH15S ORH18M ORH24L ORH32XL
A 530 ± 50 710 ± 50 990 ± 50 1400 ± 50
5. Install the brackets onto the nominated surface or structure using appropriate
screws suitable for the
mounted surface material and able to support more than double the weight of the heater being installed, refer
to on page 6.
6. Hang the heater on the brackets and secure in place with the mounting bracket locking plates
15° 45°30°
CeilingWall
A
INSTALLATION
A
B
A
B
by tighting bolts labelled A first, then B as indicated below.
Page 11
Rinnai 11 ORH OIM
ELECTRICAL CONNECTIONS
WARNING
The installation of electrical wiring, power outlets, and switches MUST BE performed by an authorised electrical installer.
GPO Connection
The heater is provided with a power cord
with a 3 pin plug (models ORH15S, ORH18M and ORH24L are
with a 10 Amp plug and model ORH32XL is with a 15 Amp plug) for connection to a dedicated single-phase 240V AC~ 50HZ earthed power outlet. Before connection, make sure that of the power outlet meet the requirements of those indicated on the appliance dataplate.
The power outlet MUST be equipped with an automatic circuit breaker with rated current not less than 16A.
For switching the heater "ON" or "OFF" an accessible All-pole disconnection switch of suitable power rating should also be provided in accordance with wiring rules.
Direct Wired Connection
The heater is designed to also allow for direct connection to a suitably rated single-phase 240V AC~ 50HZ earthed power supply. Before connection, make sure that of the power supply to the heater meet the requirements of those indicated on the appliance dataplate.
The power supply MUST be equipped with an automatic circuit breaker with rated current not less than 16A.
The installation MUST be equipped with an accessible all-pole disconnection switch of suitable power rating installed in accordance with wiring rules..
If the heater is being hard wired the circuit must be with an "ON/OFF" isolation switch, in accordance with wiring rules.
LOCATION OF ELECTRICAL CONNECTION
Electrical connections or GPO’s MUST NOT be located at the back of the heater. They MUST be located outside the installation footprint of the units to reduce the effect of damage caused by heat build-up behind the heater
When mounted on an incline ensure the electrical connection is located at the lowest point of the heater.
MULTIPLE INSTALLATIONS
For connection of more than one heater to a common "ON/OFF" isolation switch refer to your authorised electrical installer.
Correct Installation
Incorrect Installation
INSTALLATION
Page 12
Rinnai 12 ORH OIM
CLEANING
WARNING
ALWAYS TURN OFF AND OR ISOLATE THE POWER BEFORE CLEANING.
NEVER IMMERSE THE APPLIANCE IN WATER.
CAUTION
Before operating the heater for the rst time or after extended periods of non use ensure that the
surfaces are clean and free of debris or dust.
Once the radiating surface are clean avoid touching to prevent any transfer of skin oils to the heating surfaces as this may cause spotting or staining.
NEVER ATTEMPT TO CLEAN THE HEATER WHILE HOT, ALWAYS WAIT FOR IT TO COOL DOWN.
Regular removal of accumulated debris and dust will prevent unpleasant burnt odours and prevent spotting and stains on the surfaces, do this as needed or once per year�
Water ingress protection allows for safe cleaning of the external heater casing using a typical low pressure garden hose or wet cloth� ALWAYS TURN OFF AND OR ISOLATE THE POWER BEFORE CLEANING.
For more thorough cleaning of the surfaces a mild alcohol solution such as methylated spirits can be used, nish 
off with a soft dry cloth or rag�
SAVE A SERVICE CALL
SYMPTOM CAUSE
Will not heat / No operation indicator Check that power is connected and switched on�
Heater smells when rst used. This is caused by oil or dust left over from the manufacturing
process and will stop after a short time�
Faint smell for short periods after turning on the heater�
This is normal and should stop after a short time�
Heater smells when turned on after periods of non use�
Build up of debris and dust on the heater� Switch the heater off and allow it to cool down and then clean�
Clinking noises when heater is turned on and after being turned off�
This is expansion and contraction noises of the heaters metal components and is normal�
Poor heating performance� Exposure to extreme ambient conditions such as high winds /
excessively cold temperatures can lower the heating performance of an outdoor installation�
WHEN TO CALL FOR SERVICE
There are no user serviceable parts in this appliance, only an authorised person can such as a qualied electrician 
can service or maintain this appliance�
SYMPTOM CAUSE
There is a burning smell and or strange sounds (other than normal expansion and contraction noises) coming from the unit�
Turn off the heater, and contact Rinnai�
When associated circuit breaker (safety, ground) is thrown or a fuse is blown�
Turn off the heater, and contact your authorised electrical installer�
Poor heating performance� Incorrectly sized installation, contact your authorised electrical
installer�
Faulty heater element, turn off the heater, and contact Rinnai�
Will not heat / No operation indicator Check that power is connected and switched on, if still faulty, turn
off the heater, and contact Rinnai�
CARE & MAINTENANCE
Page 13
Rinnai Outdoor Radiant Heater Product Warranty
NOTICE TO CONSUMERS UNDER AUSTRALIAN CONSUMER LAW
Notice to consumers under the Australian Consumer Law:
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law� You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage� You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure�
The benets provided by this Warranty are in addition to any other rights and remedies of a consumer 
under the Australian Consumer Law and any other law which may apply to the Product�
Rinnai Australia Pty Ltd
1� WHAT IS COVERED BY THIS WARRANTY?
We warrant that your Rinnai Product purchased in Australia is free from defects in material and workmanship,
subject to the terms and conditions contained in this document�
2� WARRANTY PERIOD
This Warranty applies to any defect in your Rinnai Product which appears within the period:
(a) commencing on the installation date specied in the Compliance Certicate or, if the installation date 
cannot be established to Rinnai’s satisfaction, commencing on the date 3 months after manufacture of the Product; and
(b) determined in accordance with Schedule 1�
Any Product we repair or replace under this Warranty will only be warranted by us only for the balance of the
original Warranty Period� You may have statutory rights outside of the Warranty Period�
3� WHAT WE WILL DO
To honour this Warranty, we will:
(a) arrange for the Product to be repaired or replaced, at our option and expense, within a reasonable
period; or
(b) pay you an amount equivalent to the cost of repairing or replacing the Product�
If Rinnai provides you with either the replacement cost or replacement product, ownership of the original
product shall immediately transfer to Rinnai�
Rinnai is responsible for reasonable costs associated with legitimate warranty claims, including call-out of an
authorised Rinnai service provider to inspect the faulty product� Rinnai is not responsible for:
(a) costs for tradespeople that are not authorised Rinnai service providers; or
(b) any costs, including call-out costs for an authorised Rinnai service provider, associated with a product
which is determined upon inspection not to be covered by this warranty�
The consumer will be reimbursed by Rinnai for any reasonable costs associated with making a legitimate
warranty claim against Rinnai which are not otherwise specied above. 
Enquiries relating to Warranty claims for Rinnai products or services must be made by contacting Rinnai
Australia’s National Sales and Service department� Contact details are on the back of this document�
Rinnai 13 ORH OIM
WARRANTY
Page 14
4� WHAT WE NEED YOU TO DO
We need you to assist us with your claim by:
(a) providing us with sufcient information to clearly identify the Product such as a Certicate of Compliance, 
proof of purchase or other substantially similar document;
(b) providing us with a document which establishes that the Product was installed in accordance with the
Manual and all applicable Regulations (we recommend that you provide us with a clear and legible
Compliance Certicate for the Product);
(c) reading clause 6 of this Warranty to ensure that none of the Exclusions in this section apply�
5� WARRANTY CONDITIONS
(a) This warranty applies to products which are manufactured on or after the date of publication of this
warranty but before the next date of publication of this warranty� Please contact Rinnai’s Technical and Spare Parts department for further information about the warranty booklet publication dates�
(b) All terms of this warranty are effective from date of completion of installation� The attending service
person reserves the right to verify this date by requesting a proof of purchase or a copy of the certicate 
of compliance prior to the commencement of any warranty work� Where the date of completion of installation is not known, this warranty will commence two months after the date of manufacture� The date of manufacture is on the dataplate of the appliance�
Note: Certicates of compliance must be issued by the installer by law in all States and Territories of Australia.
(c) All Rinnai heating and cooling appliances must be installed, commissioned, serviced, repaired and
removed in accordance with the manufacturers installation instructions, current AS 3000, AS 3500 and AS 5601, local regulations and municipal building codes by persons authorised by local regulations to do so�
(d) All appliances must be installed, operated and maintained in accordance with Installation / Operation
Manual, and other technical or sales literature (“Manufacturer’s Instructions”)�
(e) Any inspection, service, repair or replacement activities associated with warranty on Rinnai products
must be authorised by Rinnai Australia before commencement�
(f) The warranty applies only to the components supplied by Rinnai� It does not apply to components
supplied by others, such as, isolating valves, electrical switches, pipe work, electrical cables, fuses and
where applicable, ue systems supplied by others, but not limited to these.
(g) Where the appliance has not been sited in accordance with the installation instructions or installed such
that normal service access is difcult, a service  charge  will  apply. If  at the discretion of the attending 
service person, access is deemed dangerous service will be refused� Any work required to gain reasonable access to the appliance will be chargeable by the attending service person (for example, removal of cupboards, doors, walls, trees, shrubs or the use of special equipment to move components
to oor level, but not limited to these).
(h) Where a product or a failed component is replaced under warranty, the time remaining on the original
Product warranty period will continue to apply and the replacement product or part will be subject to the original product warranty period�
(i) Rinnai reserve the right to transfer functional components from defective appliances if they are suitable�
(j) Rinnai reserve the right to have the installed Product returned to the factory for inspection�
Rinnai 14 ORH OIM
WARRANTY
Page 15
6� EXCLUSIONS
No warranties except those implied and that by law cannot be excluded are given by Rinnai in respect of
Goods supplied� Where it is lawful to do so, the liability of Rinnai for a breach of a condition or warranty is
limited to the repair or replacement of the Goods, the supply of equivalent Goods, the payment of the cost of
repairing or replacing the Goods or acquiring equivalent Goods as determined by Rinnai�
This Warranty does not apply if the Product is outside Australia or if the claim is wholly or partly attributable
to any:
(a) defect in installation of the Product or any failure to install, use, service, maintain and repair the Product,
in accordance with the Manual and all applicable Regulations;
(b) misuse of the Product including use of the Product for purposes other than its intended purpose, use
of the Product contrary to the Manufacturer’s Instructions, and use of the Product after it becomes apparent that it requires service, maintenance or repair;
(c) accidental damage from external sources including re, theft and explosion;
(d) acts of God and damage or corrosion to the Product caused by environmental conditions including
excessive moisture, acid rain, airborne fallout,  stones,  salt,  sand,  hail,  wind,  storms,  lightning,  oods, 
infestation by rodents or other vermin;
(e) modication of the Product in a manner not authorised by Rinnai;
(f) incorporation of parts other than Rinnai parts or other parts authorised by Rinnai;
(g) normal wear and deterioration, having regard to the operating environment of the Product, including
discolouration;
(h) failure to respond in a timely manner to any malfunction of the Product;
(i) failure due to abuse or misuse, improper maintenance, failure to maintain or improper storage�
(j) failure or damage caused by alterations, service or repair work carried out by persons other than Rinnai
service persons or service agents�
(k) where it is found that there is no fault with the Product and the issue is related to the installation or is due
to the failure of electric or gas supplies�
(l) faults or substandard performance resulting from operation outside the manufacturer’s instructions will
not be covered under this warranty�
(m) parts not supplied by Rinnai� ie� power supply faults - power isolation, refrigeration piping - drain lines
etc�
7� DEFINITIONS
“Domestic Use” means use of the Product for the climatic comfort of humans in:
(a) ordinary domestic residential premises, such as houses or apartments; and
(b) individual motel units, hotel rooms, caravans, mobile homes, and rooms in nursing homes, retirement
village complexes, schools and other care institutions and like accommodation�
“Commercial Use” means any use of the Product for the climatic comfort of humans that is not Domestic
Use�
“Product” means the Outdoor Radiant Heater manufactured by us and supplied with this Warranty in
Australia, and used exclusively in Australia�
Schedule 1 – Warranty Period
Rinnai Outdoor Radiant Heater Products Parts and Labour
Domestic Use 3 years
Commercial Use 1 year
Rinnai 15 ORH OIM
WARRANTY
Page 16
Rinnai 16 ORH OIM Issue 1 - 03/02/15
CONTACTS
Australia Pty. Ltd.
ABN 74 005 138 769
Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced every 1 years.
Head Office
100 Atlantic Drive, Keysborough VIC 3173
P.O. Box 460 Braeside, Victoria 3195
Product Sales and Service - National Phone: 1300 555 545* Fax: 1300 555 655* Technical Helpline and Spare Parts National (Mon-Fri 8am - 5.30pm EST) Phone: 1300 555 545* Fax: 1300 300 141*
*Cost of a local call higher from mobile or public phones.
E-mail: enquiry@rinnai.com.au
For further information visit: www.rinnai.com.au
Loading...