Rinnai Neo RIB2311N, Neo RIB2311L Installation Manual

Neo
Installation guide
RIB2311N/RIB2311L
For more information about buying, using, and servicing of Rinnai appliances call: 0800 RINNAI (0800 746 624).
Rinnai New Zealand Limited 105 Pavilion Drive, Mangere, Auckland PO Box 53177, Auckland Airport, Auckland 2150
Phone: (09) 257 3800, Fax: (09) 257 3899 Email: info@rinnai.co.nz Web: www.rinnai.co.nz, www.youtube.com/rinnainz, www.rinnaitraining.co.nz, www.facebook.com/rinnainz
Important:
For installations into a combustible opening, a Rinnai zero clearance box and flue kit are mandatory.
Appliance must be installed with a Rinnai approved flue system.
This appliance shall be installed in accordance with:
- Manufacturer’s installation instructions
- AS/NZS 5601 Gas Installations
- Local regulations and municipal building codes
Installation, servicing and repair shall be carried out only by authorised personnel.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life.
cnt:
Checklist ..................................................................... 4
Specification ...............................................................5
Dimensions .................................................................6
Location .....................................................................7
Mantels and surrounds ............................................... 8
Hearths .......................................................................8
Electrical connection .................................................9
TV installation above a fireplace .................................10
Enclosure dimensions ................................................11
Gas supply ..................................................................12
Flueing guidelines ......................................................13
Masonry installations .................................................14
Mock chimney installations ........................................15
Freestanding installations ..........................................16
Log set installation .....................................................17
Granule pack installation ............................................ 18
Inner frame and control panel ....................................19
Test pressures ............................................................. 20
Outer frame and dress guard .....................................21
Flame pattern .............................................................22
Commissioning ..........................................................22
Wiring diagram ........................................................... 23
4 | Neo installation guide: 11906-F 06-14
Checklist
Engine: Masonry installations
1. Rinnai Neo heater (engine)
2. Outer frame (standard or classic)
3. Glass outer dress guardstandard frame Mesh dress guardclassic frame (inbuilt models)
4. Inner frame
5. Log set and granule pack (inside appliance)
6. Semi rigid stainless steel gas pipe
7. Flared brass adaptor  “ UNF - ½ “ BSPT
8. Foam sealing strip
9. Operation and installation guides
Standard frame
Classic frame
12
2
3
4
5
5
6
7
8
3
9
Inbuilt mock chimney installations
A. Engine set (see above)
1. Spigot adaptor
2. Spigot guide panel
3. Spigot guide rails
4. Zero clearance box top panel
5. Zero clearance box rear panel
6. Zero clearance box left and right panels
7. Zero clearance box base panel
8. Hardware pack
A
3
7
2
1
8
5
6
4
Freestanding console installations
A. Engine set (refer masonry installation)
1. Spigot adaptor
2. Console top panel
3. Console right side panel
4. Console left side panel
5. Console rear panel
6. Console pillar
7. Hardware pack
1
A
3
2
7
4
5
6
Freestanding plinth installations
A. Engine set (refer masonry installation)
1. Spigot adaptor
2. Plinth top panel
3. Plinth right side panel
4. Plinth left side panel
5. Plinth rear panel
6. Plinth pillar
7. Plinth base
8. Hardware pack
1
A
3
2
4
5
6
7
8
Remote wireless controller- comes with all ETR models
1. RF combination remote wireless controller with wall mount
2. AA batteries (x2)
3. Operation guide
1
2
3
Neo installation guide: 11906-F 06-14 | 5
Specication
Neo (RIB2311N/RIB2311L)
Description
- Inbuilt gas space heater
- Burning log effect
- Glass front with glass dress guard
- Convection fan—top air discharge
Installation options
- Inbuilt masonry
- Inbuilt mock chimney
- Freestanding options
Combustion method
Bunsen type burner.
Data plate
Inside appliance on the front left hand side.
Flue - masonry
Rinnai strongly recommends the use of a Rinnai flexiliner flue system (flexi Ø 100 mm). Failure to meet this criteria may result in an unsafe situation.
Installation without a flexiliner flue is permissible as long as the chimney is checked for soundness and ability to achieve a good draw. Terminal 240 mm x 45 mm rear discharge (spigot).
Flue - decorative (mock chimney) and freestanding
Natural draft flue. An approved 100 mm cowl must be fitted to all installations. Decorative chimney installations require a Rinnai zero clearance box and zero clearance flue kit.
Flue dimensions: Inner: 100 mm Outer: 150 mm
Gas connection
½ “ BSPT, the gas supply terminates inside the heater at the front lower right hand side of the appliance.
Gas type
NG and General Product LPG.
Convection fan
2-speed centrifugal, double diameter 160 x 180 mm.
Heating area
NG: up to 107 m
2
ULPG: up to 93 m
2
Ignition
Continuous spark electronic ignition.
Input/output
Input NG: 14-30 MJ/h Input ULPG: 14-27 MJ/h
Output NG: 3.24-6.94 kW Output UPLG: 2.98-6.04 kW
Noise level
37-45 dB(A)
Power consumption
High: 50 W Standby: <3 W
1500 mm power cord is supplied with a 3-pin plug on the rear left of the appliance.
Safety devices
- Overheat switch
- Electrical fuse
- Flame failure sensing system
- Power failure
Temperature control
ETR models—thermostatic, temperature control range 7-32 °C.
Thermal efficiency
NG: 80.5% ULPG: 80%
Weight
60 kg
6 | Neo installation guide: 11906-F 06-14
Dimensions (mm)
Model External dimensions Gas connection
A B C D E E2 F G H I J
Inbuilt masonry 865 660 359 62 691 - 589 - 305 45 235
Inbuilt mock chimney 865 660 363 62 795 - 650 280 305 45 240
Freestanding console 865 760 363 62 865 712 760 280 305 140 235
Freestanding plinth 865 837 363 62 865 712 837 280 305 215 235
A A
AA
E
E
E
E
BB FF
BB
G
G
G
C D
C D
C D
C D
FF
H H
H
H
II
I
I
J J
J
J
Inbuilt masonry Inbuilt mock chimney
Freestanding console Freestanding plinth
E2
E2
Neo installation guide: 11906-F 06-14 | 7
Location
The main points governing location are flueing and warm air distribution. The heater must not be installed where curtains or other combustible materials could come into contact with the appliance. In some cases curtains may need restraining.
The Neo gas fireplace is not designed to be built into bookcases.
Standard flued appliances draw the air for combustion from the room so there is a need for adequate ventilation. Adequate ventilation must be provided as per AS/NZS 5601.1.
Clearances around the heater
The clearances listed below are minimum clearances unless otherwise stated.
75mm
400mm
1000mm
400mm
400mm
75mm
400 mm
1000 mm
400 mm
400 mm
Neo freestanding clearancesfreestanding models can be positioned directly on the floor
Neo inbuilt clearances
8 | Neo installation guide: 11906-F 06-14
A Mantel height from top of glass 400 mm min.
B Mantel depth at A - 400 mm (vertical clearance) 250 mm max.
For every 50 mm of added mantel depth, there must be an additional 100 mm of vertical clearance. For example; a mantel depth (B) of 350 mm will require 600 mm (A) of vertical clearance.
C Surround from side of glass 200 mm min.
Surround depth at C - 200 mm side clearance 250 mm max.
D Min. mantel height from floor (when heater is mounted on the
floor)
910 mm max.
E Min. width for surround 915 mm min.
Mantels and surrounds
A mantel and surround are allowed providing they are outside the minimum clearances shown below. Due to the number of different sized Neo frames, the dimensions are taken from the edge of the glass.
A - Mantel height from top
of glass
B - Mantel
depth
C - Surround
from side of glass
D - Minimum mantel height from floor
E - Minimum width for surround
Hearths
A hearth is not necessary, but can be used for decorative purposes or protection of sensitive flooring if required. It must not obscure the front of the fire.
Loading...