Congratulations on the purchase of your Rinnai LS Series Gas Fireplace. We trust you will have many years of
IMPORTANT
comfort and enjoyment from your appliance.
BEFORE INSTALLING OR USING THIS APPLIANCE
Before proceeding with the operation or installation read this manual thoroughly and gain a full
understanding of the appliance, to ensure safe and correct installation and use.
USE ONLY RINNAI GENUINE PARTS
This Flue Installation Manual provides detailed requirements and instructions for Flue Systems connected to
LS Series Gas Fireplaces.
This appliance must be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000, AS/NZS 3500 & AS/NZS 5601
• Local Regulations and Municipal Building Codes
including local OH&S requirements
This appliance must be installed, maintained and removed
ONLY by an Authorised Person.
For continued safety of this appliance it must be installed
and maintained in accordance with the manufacturer’s
instructions.
This manual to suit LS - Series Heater Models:
®
Flametech
*LS1000LS1500
RHFE0800SF *RHFE1000SRHFE1500S
RHFE0800DF *RHFE1000DRHFE1500D
®
*Incorporates Flametech
Rinnai 2 RHFE0800F_1000_1500 IM
self burning log technology.
WARNING
INSTALLATION TABLE OF CONTENTS
Warnings & Important Information 5
Before Using or Installing This Appliance ........................................................................................................................ 5
Regulatory Information ....................................................................................................................................................... 5
General Safety Warnings .................................................................................................................................................... 6
Other Conventions Used In This Manual ........................................................................................................................... 8
Flue Exhaust & Air Inlet Connections .............................................................................................................................. 13
Direct Flue Assembly 14
Direct Extended Flue Assembly 15
Vertical Flue, External Wall 17
Vertical Flue, Internal Wall 20
Sideways Flue 21
Under Floor Flue 22
Common component Assemblies 24
Precautions for All Components ...................................................................................................................................... 24
Cutting Components to Achieve a Desired Length ��������������������������������������������������������������������������������������������������������� 25
Cutting Components for a Wall Penetration �������������������������������������������������������������������������������������������������������������������� 25
This appliance MUST be installed, maintained and removed ONLY by an Authorised Person.
For continued safety of this appliance it MUST be installed and maintained in accordance with
the manufacturers instructions. Using ONLY Rinnai genuine parts.
Rinnai 3 RHFE0800F_1000_1500 IM
This page is intentionally blank
Rinnai 4 RHFE0800F_1000_1500 IM
IMPORTANT
WARNING
WARNINGS & IMPORTANT INFORMATION
BEFORE USING OR INSTALLING THIS APPLIANCE
Before proceeding with the operation or installation read this manual thoroughly and gain a full
understanding of the appliance, to ensure safe and correct use.
Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in
personal injury or death.
WARNINGS: Indicates a potentially hazardous situation which, if not avoided, could result in
personal injury or death.
CAUTIONS: Indicates a potentially hazardous situation which, if not avoided, could result in
minor or moderate injury or damage to the appliance. It may also be used to alert against unsafe
practices.
REGULATORY INFORMATION
This appliance and Flue system shall be installed in accordance with:
Manufacturer’s Installation Instructions.
Current AS/NZS 3000, AS/NZS 3500 & AS/NZS 5601.
Local Regulations and Municipal Building Codes including local OH&S requirements.
This appliance and Flue system has been certied by the Australian Gas Association. The A.G.A.
Certication Number is shown on the data plate.
This appliance and Flue system MUST be installed, maintained and removed ONLY by an
Authorised Person.
For continued safety of this appliance it MUST be installed and maintained in accordance with
the manufacturers instructions.
NOTICE TO VICTORIAN CONSUMERS
This appliance MUST be installed by a person licensed with the Victorian Building Authority.
ONLY a licensed person will have insurance protecting their workmanship.
So make sure you use a licensed person to install this appliance and ask for your Compliance
Certicate. For further information contact the Victorian Building Authority on 1300 815 127.
DRESS GUARD WARNINGS
The guard is tted to this appliance to reduce the risk of re or injury from burns and
no part of it should be permanently removed. For protection of young children or the
inrm, a secondary guard is required.
The wire dress guard supplied with this appliance MUST NOT be permanently removed as it
fulls an operational safety function. Additional dress guards including free standing types may
be used in conjunction with, but NOT replace, the dress guard supplied with this appliance.
MANDATORY INSPECTION PRIOR TO INSTALLATION
Immediately report any damage or discrepancies to the Supplier of any components. This
appliance was inspected and tested at the time of manufacture and packaging, and released for
transportation without known damage. Upon receipt, inspect the exterior for evidence of rough
handling in shipment. Ensure that the appliance is labelled correctly for the gas and electrical
supply, and/or other services it is intended to be connected to.
For safety and warranty purposes, appliances or ue components that may be damaged or
incorrect MUST NOT be installed or operated under ANY circumstances. Installation of
damaged or incorrect appliances may contravene local government regulations. Rinnai disclaims
any liability or responsibility whatsoever in relation to the installation or operation of damaged
or incorrect appliances.
Take care when opening or unpacking this appliance. Failure to do so may result in serious
injury or product failure. Check the label for the correct gas type (refer rating plate, inside the
appliance). Refer to local gas authority for conrmation of the gas type if you are in doubt.
Rinnai 5 RHFE0800F_1000_1500 IM
400mm
400mm
WARNINGS & IMPORTANT INFORMATION
MODIFICATIONS.
DO NOT MODIFY THIS APPLIANCE, modifying from original specications may create a
dangerous situation and will void your warranty. Failure to comply with these instructions could
result in a re or explosion, which could cause serious injury, death or property damage.
DO NOT modify the electrical wiring of this appliance.
If the power cord is damaged or deteriorated then it MUST be replaced by an authorised person.
Failure to do so may result in electric shock, re, serious injury or product failure.
Improper installation, adjustments, service or maintenance can cause serious injury, death or
property damage. Such work MUST ONLY be performed by an authorised person.
GENERAL SAFETY WARNINGS
This appliance is HEAVY, during installation the use of a mechanical lifting aid is recommended,
noting that improper lifting may result in serious personal injury or damage to the appliance.
WARNING: This heater MUSTNOT be used if any of the glass panels are damaged.
Flue terminal MUST always vent directly to outdoors. DO NOT extend the ue vertically or
horizontally in ways other than prescribed in this appliance manufacturer’s installation
instructions. ONLY the ue components specied by Rinnai must be used.
When considering installation ensure
minimum clearances as follows are
adhered to, refer Fig. 1.
Heat radiating from the front of
this heater may over time aect the
appearance of some materials used
for ooring such as carpet, vinyl, cork
or timber. This eect may be amplied
if the air in the room contains cooking
vapours, candle vapours and cigarette
smoke, etc. To avoid this possibility, it
is recommended that a mat or similar
protective sheet be placed in front of
the appliance, extending at least 750
mm in front of the dress guard. Refer
to the installation manual for mantle
clearances, additional installation
information and warnings.
This appliance MUSTNOT be installed where curtains or other combustible materials could
come into contact with it. In some cases curtains may need restraining.
This appliance is NOT intended for use by persons (including children) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their
safety.
The appliance is NOT intended for use by young children or inrm persons without supervision. Young children and the inrm SHOULD be supervised at all times when in the vicinity of this
heater while it is in operation.
The heater MUSTNOT be located immediately below a power socket outlet.
A dedicated 230 V earthed 10 Amp power point must be used with this appliance.
Suitable ONLY for indoor installation.
NOT to be connected to an LP gas cylinder located indoors.
Please keep this instruction booklet in a safe place for future reference. All dimensions referred
to in these instructions are in millimetres, unless otherwise specied.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIALS IN OR NEAR THIS APPLIANCE.
DO NOT PLACE ARTICLES ON OR NEAR THIS APPLIANCE.
400mm
400mm
1000mm
1000mm
750mm
750mm
Note that side and vertical
clearances are measured
from the edge of the glass.
400mm
400mm
Fig .1
Rinnai 6 RHFE0800F_1000_1500 IM
FLUE TERMINAL LOCATION
Ensure that the location of the ue terminal can comply with the requirements of AS/NZS 5601 -
Fig. 6.2 which is reproduced in part below.
AS/NZ 5601 was current at the time of printing but may have been superseded. It is the installer’s
responsibility to ensure that requirements of the current version of AS/NZS 5601 are met.
Opening into
a building
WARNINGS & IMPORTANT INFORMATION
C
T
g
T
S
LE G EN D:
I = M e c ha ni cal air in let
M = G as m ete r
P = E lec tr ic it y me ter or fuse box
S = S t r uc ture
f
T
Se e N ote 1
T = Fl ue ter minal
Z = F a n-a ss is ted a ppli ance only
Sh adin g in di c at es pro hibite d a rea for flue terminal s
Min. Clearances
metI.feR
Below eaves, balconies and other projections:
a
• Appliances up to 50 MJ/h input
• Appliances over 50 MJ/h input
From a gas meter (M) (see 5.11.5.9 for vent terminal location of regulator )
(see Table 6.6 for New Zealand requirements)
d
From an electricity meter or fuse box (P) †
e
epip lios ro epip niard a morFf
Horizontally from any building structure* = or obstruction facing a terminal
g
From any other flue terminal , cowl, or combustion air intake †
h
Horizontally from an openable window, door, non-mechanical air inlet, or any other opening into a
building with the exception of sub-floor ventilation:
• Appliances up to 150 MJ/h input *
• Appliances over 150 MJ/h input up to 200 MJ/h input *
j
• Appliances over 200 MJ/h input up to 250 MJ/h input *
• Appliances over 250 MJ/h input *
• All fan-assisted flue appliances , in the direction of discharge
Vertically below an openable window, non-mechanical air inlet, or any other opening into a
building with the exception of sub-floor ventilation:
n
• Other appliances up to 50 MJ/hr input
• Appliances over 50 MJ/h input and up to 150 MJ/h input
• Appliances over 150 MJ/h input
Natural Draught
b
Di re ction of
disch arge
(mm)
300
500
003* ecafrus rehto ro ynoclab a evoba ,dnuorg eht morFb
005* renroc lanretxe ro llaw nruter a tnorFc
1000
500
150
500
500
500
1500
1500
1500
-
0051rewolb aps a gnidulcni ,telni ria lacinahcem a morFk
051tupni rh/JM 05 ot pu sretaeh ecapS •
500
1000
1500
j
h
Door
n
j
T
e
T
P
I
h
j
Z
d
e
Se e N ote 1
a
k
k
d
M
T
T
g
g
i
iii
ii
iMinimum clearance 500mm to nearest part of roof
ii Minimum clearance 25mm to any combustible materials
iii Decktite or lead collar flashing
* - unless appliance is certified for closer installation
† - Prohibited area below electricity meter or fuse box extends to ground level.
NOTES:
1
Where dimensions c, j or k cannot be achieved an equivalent horizontal distance
measured diagonally from the nearest discharge point of the terminal to the opening
may be deemed by the Technical Regulator to comply.
2
See Clause 6.9.4 for restrictions on a flue terminal under a covered area.
3
See Figure J3 for clearances required from a flue terminal to an LP Gas cylinder.
A flue terminal is considered to be a source of ignition.
4
For appliances not addressed above acceptance should be obtained from the
Technical Regulator.
FIGURE 6.2 (in-part) MINIMUM CLEARANCES REQUIRED FOR FAN-ASSISTED FLUE TERMINALS,
ROOM-SEALED APPLIANCE TERMINALS AND OPENINGS OF OUTDOOR APPLIANCES
T
The ue terminal must be positioned away from ammable materials.
Rinnai 7 RHFE0800F_1000_1500 IM
!
DO NOTDO NOTDO NOTDO NOT
WARNINGS & IMPORTANT INFORMATION
OTHER CONVENTIONS USED IN THIS MANUAL
The following are additional terms that may be used to highlight specic requirements during
installation steps and MUST be observed.
CLEARANCES: Where required clearances will be provided and must be observed.
FALL: Ensure that the specied 2° fall is maintained to either the terminal or the appliance as stipulated.
MEASURE: Required measurements will be provided and MUST BE observed for correct installation.
CUT: Cut as required to the specied measurements.
FINISH: Ensure that burrs and swarf are removed from all cut ends.
DISCARD: Denotes items that are not required for the specic installation.
OBSERVE CORRECT ORIENTATION: Where specied ensure that components are installed with the
correct vertical or horizontal orientation.
LUBRICATE: Use the supplied container of silicone grease to lubricate components. DO NOT use other
lubricants as these may damage the ue components.
SECURE: Where specied secure components with either installer provided or component supplied xings.
DO NOT: Failure to observe DO NOT instructions will void the warranty of an appliance and may cause injury
or death.
NOTE / IMPORTANT: Where specied secure components with either installer provided or component
supplied xings.
!
INSTALLATION STOP CAUTION: Installation stop caution notes and or warnings that MUST BE observed
for safe and correct installations.
TERMINAL LOCATION
The ue terminal MUST BE positioned away from
ammable materials.
In areas subject to heavy snowfall, keep snow clear of
DO NOT
ue terminal at all times.
DO NOT ue into natural draught ues or replaces.
DO NOT ue into other rooms.
DO NOT ue into roof spaces.
DO NOT ue into under oor spaces.
DO NOT Install the heater in an unusually dusty area.
For other important information regarding the location of the heater refer to the installation and
operation manuals supplied with the appliance.
Rinnai 8 RHFE0800F_1000_1500 IM
NOTE
NOTE
NOTE
~380 mm
445 mm
(to clear flue)
300 mm min.
(top of adaptor
to first bend)
ESROOFCOWL
FLUE INSTALLATION CONFIGURATIONS
FLUE INSTALLATION OPTIONS
The following diagram provides an overview of the ue installation options available for LS-series
heaters.
ONLY the Rinnai ue system components specied in this reference manual MUST be used.
Components NOT specied in these manuals, whether manufactured by Rinnai or otherwise, are NOT compatible and MUST NOT be used!
Use ONLY the supplied silicone grease when lubricating the O-rings.
Rinnai appliance warranty conditions may be voided if non Rinnai ue components are tted.
ONLY an authorised person MUST install, service and remove the Rinnai LS-series heater &
ue system.
The maximum ue length is 8.5m* and the maximum number of 90° bends is 3**.
* For every 90 ° bend, the overall ue length MUST be reduced by 1m.
** The 90° bend of the ue transition piece is NOT counted as a 90 ° bend.
LS-series heaters are factory set for "long ue installations", which is for ue runs that are 3
metres or less. Flue runs that are greater than 3 metres in length, are specied as "long ue
installations" and will require a dip switch change, refer commissioning instructions for details.
Note 1. When cutting the ue transition for joining to other components the minimum total length
is NOT to be less than 300mm!
Vertical
LSFKIT01/02
Note 2. The ue extension all aluminium component MUST be tted at this point.
Note 3. Where stipulated a Minimum 2° fall is required to ensure correct drainage of condensation
formed in the discharge ue.
!
See Note 3.
Min 2° fall towards
the appliance
Sideways
ASPDFK
45 ° bends
!
See note 2.
!
See Note 3.
Min 2° fall towards
the flue terminal
LSFKIT01/02
Under Floor
!
See note 2.
LSFKIT01/02
Flue Exhaust
Outlet
!
See Note 3.
Min 2° fall towards
the flue Terminal
!
See note 1.
Direct
ASPDFK
ESPIPE900
!
See note 2.
!
m
to 3
up
S
o
h
e
flu
t
r
Direct Extended
ESWTERM
!
See Note 3.
Min 2° fall towards
the flue Terminal
Rinnai 9 RHFE0800F_1000_1500 IM
See Note 3.
Min 2° fall towards
the flue Terminal
Air Inlet Pipe
(supplied pre fitted)