Rinnai K309FTL, K559FTL, K559FTN Assembly Instructions

®
Assembly Instructions For
Energysaver Back Cover Kits
To suit the following Rinnai Energysaver® heaters:
MODEL KIT ORDER CODE Energysaver® 308 ESBSKA Energysaver® 309 ESBSKE Energysaver® 556 ESBSKB Energysaver® 557 ESBSKC Energysaver® 559 ESBSKF Energysaver® 1004 ESBSKD
®

GENERAL

®
IMPORTANT
®
®
2
3
1
5
4
6
®
1
2
3
4
5
6
IMPORTANT
®
1
2
A
BDD
®
A
B
B
1
2
D
3
C
B
B
3
C
Heater
Wall
3
C
BDD
®
IMPORTANT
®
The back cover kits described in these instructions are used instead of the back cover kit supplied with the Energysaver heater only when the heater is installed with the 'sideways' or 'down and out' flue system options. The back cover kits
described in these instructions are not required for any other flueing options.
For details regarding flue system options and installation refer to the ‘Co-Axial Flue System Installation Instructions - Rinnai Energysaver Space Heaters' included with flue components. Only the flue components described in this manual must be used. Other components, whether manufactured by Rinnai or otherwise, must not be used.
These assembly instructions must be read in conjunction with the ‘Co-Axial Flue System Installation Instructions - Rinnai Energysaver Space Heaters' included with flue components.

COMPONENTS

All back cover kits comprise the components listed below. The dimensions vary to suit the various Energysaver heater models.

Left cover panel Right cover panel Top cover panel Protective plastic edge Elbowed flue pipe connection Wall clip assembly
For the correct assembly sequence of this kit refer to the ‘Co-axial Flue System Installation Instructions - Rinnai Energysaver Space Heaters'.
The screws and wall bracke ts pro v id ed with the heater are required for asse mbly o f t hi s ki t. D o n ot discard these items.

SIDE PANEL ASSEMBLY

Fit left & cover panels by engaging the tabs of the cover panels into the slots of the heater . Secure to heater using the screws provided with the heater
or . Screw position is for Energysaver 309 & 559 models only.

TOP PANEL AND WALL BRACKET ASSEMBLY

Place the top cover panel into position as shown. Mark the position of the top edge of the top cover on the wall. Mark centre lines 30 mm down from the top edge mark and 4 0 mm in inwards from the left and right hand sides of the top cover panel.

Fix wall brackets to the wall at the marked positions using the screws provided. Clip the top cover panel into the wall bracket tabs and attach to the side panels using the screws provided or . S crew position is for Energysaver 309 & 559 models only
Important: Ensure flue system components are assembled and secured in accordance with the ‘Co­Axial Flue System Installation Instructions - Rinnai Energysaver Space Heaters'. Incorrect assembly could result in products of combustion dispersing into the room being heated which may
RINNAI Energysaver Back Cover Kits 1 2109030 (2009) - 10/8/10
result in a dangerous condition.
. The heater should now be secured to the wall.
Australia Pty. Ltd.
®
ABN 74 005 138 769
Internet: www.rinnai.com.au E-mail: enquiry@rinnai.com.au
Head Office
10-11 Walker Street, Braeside, Victoria 3195 P.O. Box 460 Tel: (03) 9271 6625 Fax: (03) 9271 6622