Assembly Instructions For
Energysaver Back Cover Kits
To suit the following Rinnai Energysaver® heaters:
MODEL KIT ORDER CODE
Energysaver® 308 – ESBSKA
Energysaver® 309 – ESBSKE
Energysaver® 556 – ESBSKB
Energysaver® 557 – ESBSKC
Energysaver® 559 – ESBSKF
Energysaver® 1004 – ESBSKD
®
GENERAL
The back cover kits described in these instructions are used instead of the back cover kit supplied with the Energysaver
heater only when the heater is installed with the 'sideways' or 'down and out' flue system options. The back cover kits
described in these instructions are not required for any other flueing options.
For details regarding flue system options and installation refer to the ‘Co-Axial Flue System
Installation Instructions - Rinnai Energysaver Space Heaters' included with flue components. Only
the flue components described in this manual must be used. Other components, whether
manufactured by Rinnai or otherwise, must not be used.
These assembly instructions must be read in conjunction with the ‘Co-Axial Flue System Installation
Instructions - Rinnai Energysaver Space Heaters' included with flue components.
COMPONENTS
All back cover kits comprise the components listed below. The dimensions
vary to suit the various Energysaver heater models.
Left cover panel
Right cover panel
Top cover panel
Protective plastic edge
Elbowed flue pipe connection
Wall clip assembly
For the correct assembly sequence of this kit refer to the ‘Co-axial Flue System Installation
Instructions - Rinnai Energysaver Space Heaters'.
The screws and wall bracke ts pro v id ed with the heater are required for asse mbly o f t hi s ki t. D o n ot
discard these items.
SIDE PANEL ASSEMBLY
Fit left & cover panels by engaging the tabs of the cover panels into the slots of the heater . Secure to heater
using the screws provided with the heater
or . Screw position is for Energysaver 309 & 559 models only.
TOP PANEL AND WALL BRACKET ASSEMBLY
Place the top cover panel into position as shown. Mark the position of the top edge of the top cover on the wall. Mark
centre lines 30 mm down from the top edge mark and 4 0 mm in inwards from the left and right hand sides of the top cover
panel.
Fix wall brackets to the wall at the marked positions using the screws provided. Clip the top cover panel into the wall
bracket tabs and attach to the side panels using the screws provided or . S crew position is for Energysaver
309 & 559 models only
Important: Ensure flue system components are assembled and secured in accordance with the ‘CoAxial Flue System Installation Instructions - Rinnai Energysaver Space Heaters'. Incorrect
assembly could result in products of combustion dispersing into the room being heated which may
RINNAI Energysaver Back Cover Kits 1 2109030 (2009) - 10/8/10
result in a dangerous condition.
. The heater should now be secured to the wall.
Australia Pty. Ltd.
ABN 74 005 138 769
Internet: www.rinnai.com.au E-mail: enquiry@rinnai.com.au
Head Office
10-11 Walker Street,
Braeside, Victoria 3195
P.O. Box 460
Tel: (03) 9271 6625
Fax: (03) 9271 6622
RINNAI Energysaver Back Cover Kits 2 TSD 210903(2009) - 10/8/10
National Help Lines
Spare Parts & Technical Info
Tel: 1300 555 545*
Fax: 1300 300 141*
*Cost of a local call Higher from mobile or public phones.