Rinnai infinity 32 HD 250 E, infinity 26 HD 200 E, infinity 26 internal HD 200 I, infinity 24 User Manual

How to use your
Water Heater
Infinity
Infinity 32
HD 250 E
Infinity 26 HD 200 E
26 Internal
HD 200 I
Infinity 24
Your installer is responsible for correct installation. Installation instructions are located in a pouch attached to the inside front panel of the water heater.
Temperature
Controlled
Operation
24 Hr Hot Water
In all areas
0800 746624
CONTENTS
FEATURES & BENEFITS ......................................................................................... 2
IMPORTANT INFORMATION ................................................................................. 3
OPERATION WITHOUT TEMPERATURE CONTROLLERS ............................... 7
TEMPERATURE CONTROLLERS .......................................................................... 8
STANDARD TEMPERATURE CONTROLLERS ................................................... 9
Using the Infinity with 1 Standard Temperature Controller ............................... 10
Using the Infinity with 2 or more Standard Temperature Controller ................. 11
To Turn Off your hot water system ..................................................................... 12
DELUXE BATHFILL TEMPERATURE CONTROLLERS .................................... 13
Deluxe Bathfill Kitchen Temperature Controller (MC-70-2A) .......................... 14
Deluxe Bathfill Bathroom Temperature Controller Monitor.............................. 15
Deluxe Bathfill Bathroom Temperature Controller (BC-70-2A)........................ 16
Using the Infinity with 1 Deluxe Bathfill Temperature Controller...................... 17
Setting the Sound Volume – Kitchen Bathfill Controller .................................... 18
Using the Infinity with 2 Deluxe Bathfill Temperature Controllers .................... 19
Setting the Sound Volume –Bathfill Kitchen Controller ................................... 19
Deluxe Bathfill Bathroom Controller.................................................................. 21
Using the Infinity with 3 Deluxe Bathfill Temperature Controllers and 1 Standard Temperature Controller (Infinity 26, Heavy Duty 26 and Heavy Duty 26-Internal
Only)....................................................................................................................... 24
Using the Infinity with 3 Deluxe Temperature Controllers and
1 Standard Temperature Controller ..................................................................... 25
Shower Saver / Bath Fill Function ......................................................................... 25
TROUBLE SHOOTING .............................................................................................. 26
WARRANTY............................................................................................................... 27
- 1 -
FEATURES AND BENEFITS
Congratulations on purchasing the latest in Technology Advanced Temperature Controlled Rinnai Hot Water System.
The Rinnai Infinity NEVER RUNS OUT of hot water. Whilst electricity, water and gas supplies are
connected, hot water is available whenever hot water taps are open.
Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of
the hot water supplied. The water temperature may be limited to various maximum temperatures. This is particularly useful when the hot water unit is installed where young children or the infirm may be using the hot water. The Infinity is delivered with a preset temperature of 55°C. If required, the temperature limits can be changed by an authorised person. For further information, please contact Rinnai.
The Rinnai Infinity is a power flued appliance. This makes it COMPACT, saving both floor and
wall space.
The temperature of outgoing hot water is CONSTANTLY MONITORED by a BUILT-IN
SENSOR. If the temperature of the outgoing hot water rises to more than 3°C above the selected temperature the burner is turned OFF and only turned ON again when the temperature falls to below the selected temperature.
The burner lights automatically when the hot water tap is opened, and goes out when the tap is
closed. IGNITION IS ELECTRONIC, so there is no pilot light. When the hot water tap is off, no gas is used.
‘Deluxe Bathfill’ or ‘Standard’ Temperature Controllers are available as an optional extra.
Depending on the models chosen, these offer the following additional features:
¾ Localised Temperature Controllers for up to one kitchen and three bathrooms
¾ Bath fill function (Deluxe Bathfill Bathroom Control Only)
¾ Voice Prompting (Deluxe Bathfill Control Only)
¾ Clock (Deluxe Bathfill Control Only)
Temperatures selected at the controllers are retained in the SYSTEM MEMORY.
Operating NOISE LEVEL IS VERY LOW.
ERROR MESSAGES ARE DISPLAYED on the Temperature Controllers, assisting with service.
- 2 -
IMPORTANT INFORMATION
Always check water temperature by hand before entering the shower or bath.
If freezing conditions are expected, turn off water and gas, and drain all water from the appliance.
Water Off
Gas Off
Drain Water
If power and the automatic frost protection are connected, freezing will be prevented. (“K” Series only)
DRAIN
FILTER
WATER
GAS
At low water flows, the hot water unit may go out without warning.
OFF
Do not touch the unit cover or the flue outlet. Do not insert objects into the flue outlet.
EXTERNAL INTERNAL
On cold days steam may be discharged from the flue outlet. This is normal with a high efficiency appliance and does not indicate a fault.
Keep flammable materials, trees, shrubs etc. away from the flue outlet.
EXTERNAL INTERNAL
Do not spray water directly into the flue terminal.
The hot water unit controls the water temperature automatically. To do this it sometimes needs to change the water flow accordingly. The water flow from the hot water tap may vary after the selected temperature at the Temperature Controller is altered. The water flow may also vary from summer to winter, as incoming water temperatures differ.
48º C
- 3 -
55º C
IMPORTANT INFORMATION
Do not clean the Temperature Control with solvents. Use a soft damp cloth.
Depending on the weather conditions and the length of the pipe between the hot water unit and the tap in use, there may be a variation between the temperatures displayed at the Temperature Controller(s) and the temperature of the water at the tap.
When the hot water tap is open, and hot water is flowing, the water temperature can only be increased to a maximum of 43°C on the Temperature Controller with priority.
o
C
43
ONLY
There is no need to turn the Temperature Controller(s) off after use. However, if you prefer to turn the Temperature Controller(s) off, selected temperatures will be stored in the system memory at all times whilst mains power remains connected.
48°C
If a temperature is higher than 50°C, and has been selected at the Kitchen Controller and then priority of temperature selection is transferred to a Bathroom Controller and back again, the temperature on the Kitchen Controller will drop to 50°C. This is a safety feature.
Do not push the ON/OFF button on the Kitchen Controller after having transferred priority of temperature selection to the Bathroom Controller as the system will no longer heat the water.
Turn OFF then ON.
WARNING
Someone may be about to enter a shower or fill the bath.
- 4 -
IMPORTANT
New Zealand has a service and
spare parts network in all areas.
Our Service network personnel are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs service, please ring the 0800 Rinnai service contact number on the back of this booklet. Rinnai recommend that this appliance should be serviced every 3 years.
This appliance shall be installed in accordance with:
Manufacturer’s Installation Instructions.
Current AS/NZS 3500.4
Current AS/NZS 3000
Local Water Authority Regulations.
Local Gas Fitting Regulations.
Municipal Building Codes.
NZS 5261 Gas Appliance Installation Code.
Any other relevant Statutory Regulations.
This Infinity must be installed correctly by an authorized person. The installation of gas, water, and electricity must conform to local regulations.
The installation must also comply with the instructions supplied by Rinnai.
Your heater has been approved by the Australian Gas Association A.G.A. Approval Number shown on Data plate.
Please keep this instruction booklet in a safe place for future reference.
All dimensions referred to in these instructions are in millimeters, unless otherwise specified.
N10378
- 5 -
Distributed and Serviced in Australia under a Quality system certified as complying with ISO 9002 by Standards Australia Quality
IMPORTANT INFORMATION
Excessively hot water is dangerous, especially for young children and the infirm. The Infinity allows you to control the temperature of your hot water to safe levels.
Water temperatures over 50°C can cause severe burns
DANGER
HOT
BURN
instantly or death from scalds.
Children, disabled, and the elderly are at highest risk of being scalded.
Feel water before bathing or showering.
Burns from hot water taps can result in very severe injuries to young children. Hot water at 65°C (the average hot water temperature in New Zealand) can severely burn a child in less than half a second. At 50°C it takes five minutes.
Burns can occur when children are exposed directly to hot water or when they are placed into a bath which is too hot.
DO
DON’T
Do stay with children whenever they are in the bathroom. (Take the phone off the hook). Do take them out of the bathroom if you need to answer the phone or door. Do test the temperature of the water with your elbow before placing your child in the bath. Do make sure that the tap is turned off tightly. Do consider setting your Infinity at a maximum temp. of 50°C. (Contact Rinnai New Zealand) Do install a child proof tap cover OR, Do install a child resistant tap.
Don’t leave a toddler in the care of another small child. The older child may not have set the water temperature to a safe level.
Consider child-resistant
taps or inexpensive tap covers, both of which
prevent a small hand being able to turn on the tap.
Consider reducing the
temperature of the water coming from the hot water tap to 50°C.
This approach can be extremely valuable because it requires a one time action for a long­term reduction in the risk of scalds. This type of automatic protection is important during times when a parent or carer has been distracted.
- 6 -
37°C
C.
OPERATION WITHOUT TEMPERATURE CONTROLLERS
The Infinity has no pilot light and when installed without Temperature Controllers, the Infinity will operate automatically as soon as a hot water tap is opened.
The burner ignites with electronic ignition and the flame extinguishes as soon as water flowing through the appliance stops.
Simply, open a hot water tap.
HOT
COLD
NOTE
55°C
The Infinity is factory pre-set to 55°C. If you require greater control over the temperature of your hot water, contact Rinnai about our temperature controllers to allow precise digital temperature control in the range
~ 55°
Controllers can be easily fitted at any time after installation.
NOTE
- 7 -
TEMPERATURE CONTROLLERS
The purpose of the Temperature Controllers is to enable the user to have complete control over the hot water unit. Used correctly, the hot water unit will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used. Adjustments to the operation of your hot water unit can be made with any of the Temperature Controllers. Each Temperature Controller can be individually programmed.
Various water temperatures (°C) can be selected as follows:
Kitchen Controller:
37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55°C
Bathroom Controller
Hot Water Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50°C
Bath fill Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48°C
If a temperature between 43°C and 50°C is selected on a Bathroom Controller and this temperature is then decreased to below 43°C and increased again whilst the water is running, the maximum selectable temperature will become 43°C. This provides additional safety for the consumer.
Suggested temperatures are:
Kitchen 50°C Shower 42°C Bath fill 40°C
These temperatures are suggested starting points for selection. You may find higher or lower temperatures are more comfortable. Maintaining lower temperatures helps to save energy. To obtain water temperatures lower than 37°C simply add cold water.
Temperature Controllers are an optional extra. ‘Standard’ and ‘Deluxe Bathfill’ Temperature Controllers can be fitted. Standard Controllers allow temperature selection only. Deluxe Bathfill Controllers have temperature selection, bath fill and clock functions.
Temperature Controllers allow the temperature to be set from various locations. The temperature selected will be available to all outlets.
Controller Options
Model
Infinity 26 Infinity 32 Infinity 24
Deluxe Bathfill Temperature
Controllers
MC-70-2A, BC-70-2A, MC-91-1A
Standard Temperature Controllers
- 8 -