Rinnai infinity 20-2021 Customer Operation & Installation Manual

Temperature Controlled Continuous Gas Hot Water System
Simply the best hot water system available.
^
CUSTOMERS OPERATING
INFORMATION
AND
-
INSTALLATION INSTRUCTIONS
This appliance shall be installed in accordance with:-
Manufacturer’s Installation Instructions Local Water Authority Regulations Local Gas Fitting Regulations Municipal Building Codes
A.G.A.1G.A.N.Z. Installation Code for Gas Burning Equipment Any other relevant Statutory Regulation This appliance must only be installed, serviced and removed by an Authorised Person.
CONTENTS
Features
.................................................................................
1
CUSTOMERS OPERATING INFORMATION
Remote Controls
........................................................................
2
Remote Control Layout
................................................................
3
Turning the Infinity 20 ON
..............................................................
4
Adjusting Temperature
.................................................................
4
Transferring Priority of Temperature Selection
.......................................
5
Turning the Infinity 20 OFF
............................................................
6
Safety Points
............................................................................
7
Important Points
............................
..‘.
.........................................
8
Error Messages
.........................................................................
9
Guarantee Information
...............................................................
10
INSTALLATION INSTRUCTIONS
-Unpacking
......................................................................
11
- Positioning
.....................................................................
12
- Installation - General
.........................................................
13
- Remote Controls - General
..................................................
14
- Remote Controls - Installation
............................................
15-17
- Testing
..........................................................................
18
Wiring Diagram
..........................
.............................................
19
Block Diagram
........................................................................
20
Dimensions
...........................................................................
21
FEATURES OF YOUR INFINITY 20
n The Infinity 20 is one of the most advanced water heaters available. It supplies hot
water at the temperatures selected on either of the two electronic Remote Controls supplied as standard with the appliance.
w The Master Control (larger control) can be fitted conveniently close to the shower
or bath area, and is used to override the Sub Control (smaller control) which is
normally fitted in the kitchen or other convenient area.
n The Transfer button on the Master Control enables you to select and lock the
preferred temperature for shower or bath water. When locked in, this selected temperature cannot be overridden by the Sub Control.
n The Sub Control is used to select temperatures for kitchen, laundry etc.
n Temperatures selected at both Controls are retained in the system memory. n The Infinity 20 never runs out. While the electricity, gas and water supplies are
connected, hot water is available for as long as the hot water tap is open.
n The burner lights automatically when the hot water tap is opened, and goes out
when the tap is closed.
n AGA’s 5 Star Energy Rating makes the Infinity 20 one of the most efficient water
heaters available.
n The Infinity 20 is an externally mounted, power flued appliance. It is very compact,
saving both floor and wall space. n Operating noise levels are very low. H Error codes are displayed on the Remote Controls, assisting with service. H Other features include automatic frost protection and over heat protection.
This Infinity 20 must be installed correctly by an authorised person. The installation
of gas, water and electricity must conform to local regulations. The installation must also comply with the instructions supplied by Rinnai. Your Infinity20 has been approved byThe Australian Gas Association andTheGas Association of New Zealand.
A.G.A. Approval Number 4673
G.A.N.Z. Approval Number 694
Please keep this instruction booklet in a safe place for future reference.
All dimensions referred to in these instructions are in mm,
unless otherwise specified.
-l--
Customers Opemting Infomtation
PLEASE READ THESE INSTRUCTIONS CAREFULLY
To obtain the best performance out of your Infinity 20 it is important to use the Remote Controls correctly.
Used as intended, the Infinity 20 will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used.
1
REMOTE CONTROLS
~~~ -1
The purpose of the Remote Controls is to enable you to have complete control over your Infinity 20 from inside your house.
Two Remote Controls are supplied with the Infinity 20. The Master Control has a
Transfer button. This Control has the ability to override theSubControl and lock in the
water temperature selection desirable for shower and bathroom areas. It is suggested that theMasterControl with theTransfer button beconvenientlyplaced nearthe shower,
bathroom area or other location where priority control of water temperature is required.
Normally, the Sub Control, without theTransfer button, would be located in the kitchen or other convenient area, such as the laundry.
All necessary adjustments to the operation of your Infinity 20 can be made with either of
the two Remote Controls. A different temperature can be stored in the system memory of each Control.
Various water temperatures can be selected in 16 steps from 35W to 75%. The temperatures are 35-37-38-39-40-41-42-43-44-45-46-48-50-55-60-75OC.
Suggested temperatures are Shower 42OC
Kitchen 50°C.
These temperatures are suggested starting points for selection. You may find higher or
lower temperatures are more comfortable. Maintaining lower temperatures helps to save energy
-2-
REMOTE CONTROL LAYOUT
1
2
6
1
3
1
6
2
MASTER CONTROL
6
SUB CONTROL
Number Control Function
1
ON/OFF
Power switch to operate Infinity 20 hot water service.
2 COMBUSTION INDICATOR
Indicates that a hot water tap is open in any location, while the Infinity 20 has been turned ON and is operating.
3
ON INDICATOR
Indicates which Remote Control is
in control of adjusting the water
temperature selection.
4 TRANSFER
Alternates the control of temperature selection between Master and Sub Controls.
5 THERMOSTAT CONTROL
Adjusts the temperature selection
in 16 steps from 35% to 75%. Selected temperatures are stored in the system memory.
6 DIGITAL MONITOR
Indicates the temperature which has been selected. Error Code flashes in the event of a fault.
-3-
TURNING THE INFINITY 20 ON
n TO TURN YOUR INFINITY 20 ON.
Simply press the ION/OFFI button on either Control.
The ON indicator will glow on the
Control which you have operated. This indicates that the Infinity 20 is
ready to supply hot water as soon
as a tap is opened. To operate the Infinity 20 simply
turn any hot water tap on. This
will automatically light the burner
providing hot water at the
temperature displayed on the
Digital Monitor.
After installation, and when the
loN/OFFI button is first pushed,
42% will be displayed on the Digital
Monitor.
This is a safety feature. Thus even
if the shower is used without first
adjusting the temperature the hot
water will be at a safe temperature.
Master Control
Sub Control
r
ADJUSTING TEMPERATURE
n TO INCREASE OR DECREASE
THE WATER TEMPERATURE.
The temperature can only be adjusted on the Remote Control where the ON indicator is
glowing, and the same temperature will be displayed on both Controls.
required temperature is displayed on the Digital Monitor.
When any hot water tap is turned
on, hot water will be supplied at the temperature displayed on the Digital Monitor.
CHECK WATER TEMPERATURE
BEFORE ENTERING SHOWER
OR BATH
-4-
TRANSFERRING PRIORITY OF
TEMPERATURE SELECTION
n To Transfer priority of water
temperature selection to the
Master Control, simply press the ITRANSFER 1 button on the Master Control.
The ON indicator on the Master Control will glow to indicate that priority of water temperature selection has been transferred to the Master Control.
After having transferred the priority of water temperature selection, 42W will be displayed on the Digital Monitor.
.
n The water temperature can now be
selected using the Master Control. Once the desired water
temperature is selected, the Remote Control will store it in the system memory until the temperature is changed or the mains power supply is turned off.
You can alternate priority of water temperature selection
between the Master and Sub Controls, without erasing the individually stored temperatures from the system memory.
n To Transfer priority of water
temperature selection back to the Sub Control, simply press the 1st button again. The temperature displayed will then
return to the temperature which
was previously selected at the Sub Control, and the ON indicator will glow to indicate priority control of
water temperature selection.
Master Control
-5-
TURNING THE INFINITY 20 OFF
n TO TURN YOUR INFINITY 20 OFF Simply press the -1 button
on either Remote Control.
This will shut the Infinity 20 down completely
If hot water taps are opened when the Infinity 20 is OFF, cold water will flow from the taps.
Selected temperatures are retained
in the system memory, even when the Remote Controls have been turned OFF.
When the Controls are turned ON again, the previously selected temperatures will be displayed on
the Digital Monitor.
.
NOTE:
It is recommended that during long
periods of non-use, the system be switched off at the Remote Controls.
-6-
Loading...
+ 16 hidden pages