INFINITY® gas hot water
heater internal ueing
Installation guide
![](/html/eb/ebe3/ebe3c92f7184fa8996ff6dd6989bf56a057486993927b5dab0b3d088e5586a5c/bg2.png)
Rinnai INFINITY® gas hot water heater flueing shall be
installed in accordance with:
- Manufacturer’s installation instructions
- Local regulations and municipal building codes
Installation, servicing and repair shall be carried out only
by authorised personnel.
Owner, please retain this guide for future reference.
Installer, please leave this guide with the owner.
Warning
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life.
Important:
For more information about buying, using, and servicing
of Rinnai appliances call: 0800 RINNAI (0800 746 624)
Rinnai New Zealand Limited
105 Pavilion Drive, Mangere, Auckland
PO Box 53177, Auckland Airport, Auckland 2150
Phone: (09) 257 3800
Fax: (09) 257 3899
Email: info@rinnai.co.nz
Web: www.rinnai.co.nz
www.youtube.com/rinnainz
www.facebook.com/rinnainz
![](/html/eb/ebe3/ebe3c92f7184fa8996ff6dd6989bf56a057486993927b5dab0b3d088e5586a5c/bg3.png)
cnt:
Flueing options and suitability......................... 4
Flueing guidelines ........................................... 5
Flue spigots and condensate ........................... 6
UV protectors .................................................. 7
Cutting to size ................................................. 7
Direct flueing using FFSSKIT ............................ 8
Horizontal extension flueing ........................... 8
Combination flueing ....................................... 9
Flue components ............................................ 10
![](/html/eb/ebe3/ebe3c92f7184fa8996ff6dd6989bf56a057486993927b5dab0b3d088e5586a5c/bg4.png)
4 | Continuous ow internal ueing guide: 11748-D 04-13
Direct flueing: For installations where the internal continuous flow unit is mounted directly on the
inside of an external wall with a maximum thickness of 430 mm (EF models) and 485 mm (XR/HD
internal models.
Horizontal extension flueing: The same as direct flueing with additional pipe required due to the
longer horizontal distance.
Vertical straight flueing: Installations where the internal unit is flued vertically through the roof.
Combination vertical and horizontal flueing: A combination of all the above.
Flueing options and suitability
1
2
3
4
Description
The flueing for internal
water heaters is a coaxial
design. It has a stainless
steel inner pipe to discharge
products of combustion and
a thermoplastic outer pipe for
air supply to the appliance.
The Rinnai INFINITY® internal
gas hot water heaters are room
sealed appliances—sealed
from the room as it takes
air for combustion from the
outside, and expels products
of combustion outside. No
ventilation in the space where
the water heater is installed is
required.
Each Rinnai INFINITY® water
heater is flued individually.
Suitability
The flueing components
outlined in this guide are
suitable for the following
Rinnai INFINITY® models
EFi250 REU-KM3237FFUD
HDi200 REU-VR2632FFUG
HDi200 REU-VRM2632FFUG
HD200i REU-VRM2632FFUG
HD200ia REU-VRM2632FFUC
XR26i REU-VR2632FFUG
XR26ia REU-VR2632FFUG
Female flue spigot (4913)
All of the ‘suitable’ models
have a female flue spigot at the
top of the unit.