Rinnai I10, I20 Operation Manual

This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed and maintained in
Operation Manual
I Series Evaporative Air Coolers
Rinnai 2 I Series Evap AC OM
TABLE OF CONTENTS
Warnings and Important Information 3
Regulatory / Installation / Safety �������������������������������������������������������������������������������������������������������������������������������������������� 3
Electrical Supply Cord ����������������������������������������������������������������������������������������������������������������������������������������������������������� 3
Models Covered In This Manual �������������������������������������������������������������������������������������������������������������������������������������������� 3
Evaporative Cooler Operation 4
Introduction ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 4
How Does Your Evaporative Cooling Work? ������������������������������������������������������������������������������������������������������������������������� 4
Before Operating Your Evaporative Cooler ���������������������������������������������������������������������������������������������������������������������������� 4
The Air Smells A Little Different, Why? ���������������������������������������������������������������������������������������������������������������������������������� 5
Electrical Supply Cord ����������������������������������������������������������������������������������������������������������������������������������������������������������� 5
Start Up ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 5
Shut Down ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 5
On Humid Days ��������������������������������������������������������������������������������������������������������������������������������������������������������������������� 5
Ceiling Exhaust Vent(s) ��������������������������������������������������������������������������������������������������������������������������������������������������������� 5
Wall Control Operation 6
About Your Rinnai Programmable Wall Controller ����������������������������������������������������������������������������������������������������������������� 6
Automatic Pre-Wet ����������������������������������������������������������������������������������������������������������������������������������������������������������������� 6
Operating Modes ������������������������������������������������������������������������������������������������������������������������������������������������������������������� 6
AUTO COOL Operation Mode ������������������������������������������������������������������������������������������������������������������������������������������ 6
MANUAL Operation Mode ������������������������������������������������������������������������������������������������������������������������������������������������� 7
FAN ONLY Operation Mode ���������������������������������������������������������������������������������������������������������������������������������������������� 7
Using The Timer �������������������������������������������������������������������������������������������������������������������������������������������������������������������� 7
Setting The Cooler To Turn Itself ON ������������������������������������������������������������������������������������������������������������������������������������� 7
Setting The Cooler To Turn Itself OFF ����������������������������������������������������������������������������������������������������������������������������������� 7
Zoned Systems ���������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8
Batteries ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8
Care & Maintenance 9
Cooler Service & Maintenance ���������������������������������������������������������������������������������������������������������������������������������������������� 9
Save A Service Call ��������������������������������������������������������������������������������������������������������������������������������������������������������������� 9
Installation Record ��������������������������������������������������������������������������������������������������������������������������������������������������������������� 10
Service Schedule / Record �������������������������������������������������������������������������������������������������������������������������������������������������� 10
FAQ 11
Warranty 13
Contacts 16
Rinnai 3 I Series Evap AC OM
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death�
WARNINGS: WHEN IGNORED, CAN RESULT IN SERIOUS INJURY OR DEATH.
CAUTIONS: WHEN IGNORED, CAN RESULT IN MINOR INJURY OR PRODUCT DAMAGE.
SHALL / MUST /
IMPORTANT:
INDICATES A MANDATORY REQUIREMENT OF THIS MANUAL.
SHOULD: INDICATES A RECOMMENDED REQUIREMENT OF THIS MANUAL.
Any deviations from these instructions may, at the discretion of Rinnai, void the warranty. As a result, the customer and/or installer may be charged a fee for product non-warranty related call outs. Also, note that failure to comply with these instructions may preclude Rinnai from being able to service the unit.
DISCLAIMER: This document is a guide only. Laws, regulations and industry standards can
vary between States and Territories.
Accordingly, this guide MUST BE read in conjunction with, and subject to, all laws, regulations and industry standards applicable in the State or Territory in which the products are installed. You MUST ensure that the installation of the products will comply with those laws, regulations and standards, and that the
products recommended to customers are t for the purpose for which they
are intended.
WARNING
REGULATORY / INSTALLATION / SAFETY
This appliance SHALL BE installed in accordance with:
Manufacturer’s Installation Instructions�
Current AS/NZS 3000 (electrical codes)�
Local Regulations and Municipal Building Codes including local OH&S requirements�
Local water authority regulations
Duct xing regulations, EPA guidelines and AS HB276-2004 “A Guide to Good Practice”
ALWAYS comply with the following precautions to avoid dangerous situations and to ensure optimum performance�
This appliance MUST BE installed, maintained and removed by an Authorised Person�
DO NOT place any articles on or against this appliance
DO NOT use or store ammable materials near this appliance
DO NOT spray aerosols in the vicinity of this appliance while it is in operation
DO NOT modify this appliance
This appliance is NOT intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety�
Children should be supervised to ensure that they DO NOT play with the appliance�
ELECTRICAL SUPPLY CORD
If the electrical supply cord is damaged, it must be replaced by Rinnai, an authorised service agent or
similar qualied persons in order to avoid a hazard.
IMPORTANT
MODELS COVERED IN THIS MANUAL
Rinnai I Series I20 I10
IMPORTANT
WARNINGS AND IMPORTANT INFORMATION
Rinnai 4 I Series Evap AC OM
INTRODUCTION
Congratulations on your purchase of a Rinnai Cooling system. For you to achieve the performance and efciency expected from your new cooler, please ensure the installer is a qualied trades person, that the installer has
commissioned the unit before you commence operating, and you take the time to read the contents of this manual�
In some Australian States it is mandatory that your cooler installation is issued with a certicate of compliance
to guarantee the installation workmanship� Please check with your installer or the local plumbing authority or association� The Rinnai cooler is covered by the product warranty as outlined in this manual�
HOW DOES YOUR EVAPORATIVE COOLING WORK?
The amount of cooling available from any type of cooling system is dependent on the outside weather conditions� Your evaporative cooler works best on hot, dry days� It is essential to provide the required amount of ventilation (for your evaporative cooling system to function properly) by opening windows/doors whenever the cooler is operating�
Air is drawn in through the lter pads resulting in 100% fresh cool air entering the home. The movement of this
cooled air through your home will draw the heat out of the house, so be sure that doors or windows are open to expel this heat to outside�
Whenever possible start the cooler early to prevent the build up of heat within the house, and on sultry or humid days your cooler may work better with the fan ONLY running and the pump turned OFF� Stale air, cigarette smoke and fumes can be quickly cleared and replaced with fresh air by turning the fan to manual mode�
BEFORE OPERATING YOUR EVAPORATIVE COOLER
Make sure enough window and/or door area is open for the unit to work correctly� The following table gives a guide to the amount of open area required for each model in m2, and also gives suggestions on how to provide this�
Model
Number of average size windows & doors
(suggestive only)
Highest
Fan
Setting
Lowest
Fan
Setting
I20 Three sliding windows or one door & two hinged windows
2�3 m
2
1�4 m
2
I10 Six hinged windows or four hinged windows and one sliding window 1�8 m
2
0�8 m
2
Door = 1.6m²
Hinged Window = 0.3m²
Sliding Window = 0.7m²
Average ventilation area provided by various openings when fully opened�
NOTE
You can also choose to have these openings only halfway open, however note that the opening will only provide half the amount of ventilation shown above and additional ventilation openings would be required.
To cool your whole house, you need windows and / or doors open throughout the house�
If you wish to concentrate your cooling to a select area, simply concentrate all the required ventilation in the targeted area (see the following diagram on page 5)�
EVAPORATIVE COOLER OPERATION
Rinnai 5 I Series Evap AC OM
This iIllustration shows the method of getting effective cooling in desired areas of the home
Evaporative air conditioner in roof
Closed Windows
Open Windows
The cooled air flows towards the points of ventilation, cooling as it moves through rooms
Concentrated
cooling in this area
NOTE
On hot, windy days, ensure that the windows and /or doors open for ventilation are on the sheltered side of the house.
THE AIR SMELLS A LITTLE DIFFERENT, WHY?
New Cooling pads can give off a mild odour while they are settling in� This is quite normal, it will dissipate quickly
as the new pad is constantly ushed during use.
ELECTRICAL SUPPLY CORD
If the electrical supply cord is damaged, it must be replaced by Rinnai, an authorised service agent or similar
qualied persons in order to avoid a hazard.
START UP
When the cooling is rst turned ON, there will normally be a delay before the cool air is delivered from the duct outlets. The delay time allows water to ll the Cooler’s tank and/or Pre-wet the lter pads.
The entire process can take up to 4 minutes before cool air is expected from the duct outlets�
SHUT DOWN
There is a delay of up to 6 minutes after the system is turned off, during which time the Rinnai I Series Cooler performs a self clean and dry function�
All water will be drained from the unit 45 minutes after the unit has been turned off�
ON HUMID DAYS
On days of high humidity your evaporative cooler works best with the fan on high and perhaps the pump switch turned off�
If moisture is building up on tiled or hard surface areas, ensure that airow from the outlets is directed across the ceiling rather than down towards the oor. Also ensure that you have enough windows and/or doors open.
CEILING EXHAUST VENT(S)
(Security Relief Vents)
Ceiling exhaust vents (security relief vents) are not recommended as recirculating air will impair performance of the cooler�
EVAPORATIVE COOLER OPERATION