Page 5
Safety
Precautions
Warning
1. Installation MUST BE performed by an authorised dealer or specialist. Defective installation can
cause water leakage, electrical shock or fire.
2. Installation MUST BE performed according to the installation instructions. Improper installation
can cause water leakage, electrical shock or fire.
3. Contact an authorised service technician for repair or maintenance of this unit.
4. Only use the included accessories, parts, and specified parts for installation. Using non-standard
parts can cause water leakage, electrical shock or fire, and cause the unit to fail.
5. Install the unit in a firm location that can support the units weight. If the chosen location cannot
support the units weight, or the installation is not done properly, the unit may drop and cause
serious injury or damage.
6. For all electrical work, follow all local and national wiring standards, regulations, and the
installation manual. You MUST use an independent circuit and single outlet to supply power.
DO NOT connect other apppliances to the same outlet. Insufficient electrical capacity or defects
in electrical work can cause electrical shock or fire.
7. For all electrical work, use the specified cables. Connect cables tightly, and clamp them securely
to prevent external forces from damaging the terminal. Improper electrical connections can
overheat and cause fire, and may also cause shock.
8. All wiring MUST BE properly arranged to ensure that the control board cover can close properly.
If the control board cover is not closed properly, it can lead to corrosion and cause the
connection points on the terminal to heat up, catch fire, or cause electrical shock.
9. In certain functional environments, such as kitchens, server rooms, etc., the use of specically
designed air-conditioning units is highly recommended.
10. If the supply cord is damaged, it MUST BE replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
OPERATION RANGE LIMITATIONS
The table below indicates the temperature ranges the air conditioner can be operated within.
COOL Mode HEAT Mode DRY Mode
Room Temperature 0°C ~30°C 10°C ~ 32°C
Outdoor Temperature -15°C ~ 30°C
17°C ~ 32°C
-15°C ~ 50°C 0°C ~ 50°C
CAUTION
For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of any
combustible materials.
DO NOT install the unit in a location that may be exposed to combustible gas leaks. If combustible
gas accumulates around the unit, it may cause fire.
DO NOT operate your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
1. The product must be properly earthed at the time of installation, or electrical shock may occur.
2. Install drainage piping according to the instructions in this manual. Improper drainage may
cause water damage to your home and property.