45
* Minimum operation pressure and flow based on temperature setpoint and inlet conditions.
** When the water heater is not installed in an area of negative pressure.
*** When protected from direct wind exposure.
TECHNICAL DETAILS
Model REU-KBM3237FFUDHD-E REU-KBM3237WDHD-E Unit
Installation Internal External
G20 Nat Gas Press Low / High 1,2 / 7,6 1,2 / 8,1 mbar
G230 Air/Propane Press Low / High 1,4 / 9,0 1,4 / 9,2 mbar
G31 Propane / G30 Butane Press Low / High 1,3 / 9,2 1,3 / 8,9 mbar
Flue System Forced Room Sealed Direct Forced Exhaust
Temp. Range Controllers 37-46,48,50,55, (HD:60,65,75) 37-46,48,50,55, (HD:60,65,75) °C
Temp. via dip switches 40, 42, 50, 55, 60, 65, 75, 85 40, 42, 50, 55, 60, 65, 75, 85 °C
Ignition Direct Elecronic Ignition
Gas Consumption & Capacities min conditions
Hi = net calorific value Hs = gross calorific value
G20 Nat Gas: Input Qm: Hi/Hs | Useful output P
m
4,05/4,5|4,01 4,05/4,5|4,01 kW
G20 Nat Gas flow normal operating conditions V
m
0,43 0,43 m3/hr
G230 Air/Propane Input Qm: Hi/Hs | Useful output P
m
4,14/4,5|4,01 4,14/4,5|4,01 kW
G230 Air/Propane flow normal operating conditions V
m
0,34 0,34 m3/hr
G30 Input Qm: Hi/Hs | Useful output P
m
4,72/5,11|4,55 4,72/5,11|4,55 kW
G30 flow normal operating conditions M
m
0,37 0,37 kg./hr
G31 Input Qm: Hi/Hs | Useful output P
m
4,14/4,5|4,01 4,14/4,5|4,01 kW
G31 flow normal operating conditions M
m
0,32 0,32 kg./hr
Gas Consumption & Capacities nominal condit.
Hi = net calorific value Hs = gross calorific value
G20 Nat Gas: Input Qn: Hi/Hs | Useful output P
n
52,6/58,4|56,6 52,6/58,4|56,6 kW
G20 Nat Gas flow ref. conditions V
r
5,6 5,6 m3/hr
G230 Air/Propane: Input Qn: Hi/Hs | Useful output P
n
53,7/58,4|56,6 53,7/58,4|56,6 kW
G230 Air/Propane flow ref. conditions V
r
4,4 4,4 m3/hr
G30 Input Qn: Hi/Hs | Useful output P
n
61,3/66,4|64,4 61,3/66,4|64,4 kW
G30 flow normal operating conditions M
n
4,8 4,8 kg./hr
G31 Input Qn: Hi/Hs | Useful output P
n
53,7/58,4|56,6 53,7/58,4|56,6 kW
G31 flow normal operating conditions M
n
4,2 4,2 kg./hr
Country of destination GB,IE,FR,NL,PL(I3P only)
Gas category and pressure I2H G20-20mbar / I3P G31-37mbar / I3B/P G30-30mbar
Type C13,C33,C53,C83P,B33P A3
Max Flow 37 37 L/min
Min Operation Flow
ON=1,5 * / OFF=1,0 * ON=1,5 * / OFF=1,0 *
L/min
Operating Water Pressure (Pw ) 1,0 * - 10 1,0 * - 10 Bar
Power Supply 230V/50Hz
Electric Consumption (1 remote) 64 63 W
Electric Consumption standby (1 remote) 2 2 W
Electric Consumption (antifrost) 153 168 W
Ignition safety time T
SAmax
4,2 4,2 Sec.
Weight 28 28 kg
IPx Protection - IPX4 -
Anti-freeze outside temperature
-30°C ** -20°C ***
°C
NOx at Max Input GCV O2 0% G20 / G30 / G31 30 / 140 / 45 30 / 80 / 45 mg/kWh
Load Profile
XXL XXL
Water Heating Efficiency η wh
86.3 86.3 %
Daily Fuel Consumption Qfuel 28.195 28.195 kWh
Daily Electrical Consumption Qelec 0.089 0.089 kWh
Sound Power Level L WA 59 - dB