Rinnai EX08C Specification

EX08C (RHFE-202FTA)
Type of Appliance
Rinnai Model Number Gas Rate Input (BTU/hour)
Gas Rate Output (BTU/hour)
AFUE Rating Minimum Gas Supply Pressure Maximum Gas Supply Pressure Electrical Connection Gas Connection Combustion System Ignition System Fan CFM Output Temperature Settings
Temperature Control
Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
RHFE-202FTA-A-N (Natural gas) RHFE-202FTA-A-P (Propane)
Low - 3,000 Low - 3,000 High - 8,000 High - 8,000
Low - 2,400 Low - 2,400 High - 6,400 High - 6,400
82% 83%
4.5 in (114 mm) W.C. 8 in (203 mm) W.C.
10.5 in (267 mm) W.C 13 in (330 mm) W.C. AC 120V, 60 Hz, 41 watts 1/2 inch NPT Stainless steel Bunsen burners Electronic spark ignition Low - 48.3 High - 78.6 Low (LO): minimum combustion
60° - 80° F in 2° increments High (HI): maximum combustion
Electronic thermostat
Temperature limiting program to comply with Inside Design
Temperature limits
Humidifier Tray Weight Clearance from Combustibles Noise Level Warm Air Outlet
FEATURES
Restart capability: Timer Settings: Seven-stage modulating gas valve: Negative coefficient thermistor: Variable speed inducer motor with
pressure switch: Self diagnostic electronics:
Quiet operation:
© 2011 Rinnai Corporation
Enameled tray with capacity of 1.5 pints (700 cc) Approximately 46 lbs (21 kg) Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m) 27 - 36 dB(A) Bottom front louvers
restarts automatically when ignition or combustion fails starts and turns off the heater at 2 timer settings provides precise gas flow by operating from one to seven stages detects temperature change in 1/2 of a degree monitors and controls combustion fan and allows the appliance to
overcome winds of up to 40 mph continually monitors functions; provides auto shutdown codes; indicates
when air filter needs cleaning reduces noise through use of swept blades in convection fan; quiet
expansion / contraction of parts due to temperature changes
RHFE-202FTA SP 6/2011
EX08C (RHFE-202FTA)
Safety Devices
Venting Maximum Vent Length Wall Thickness and
Flue Manifold Kits
(the “A” vent kit is included with the appliance)
Flame rod detects flame failure; results in auto shutdown to prevent escape of gas
Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown
3 amp fuse protects against power surge; results in auto shutdown
Abnormal spark at time of ignition results in auto shutdown
Combustion fan purges any gas from the combustion chamber before
ignition
Convection fan continues to run after burner shutdown to cool internal parts
Child lock prevents inadvertent operation
Appliance shuts down if room reaches 104° F (40° C)
concentric; 3 1/8 inch (80 mm) wall hole no extensions allowed; flue manifold termination connects directly to unit
Name Kit No. fits walls
S Vent Kit FOT-150 3 - 4 1/2 in (75 - 115 mm) A Vent Kit FOT-151 4 1/2 - 9 1/2 in (115 - 240 mm) B Vent Kit FOT-152 9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/ 8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/ 2 in (600 - 800 mm)
Warranty Conversion Kit
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
27.375 in
(695 mm)
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years To natural gas: 204000033 To propane gas: 204000037
18.25 in (465 mm)
24.44 in (88 mm)
24.375 in
(620 mm)
10.1 in (257 mm)
6.8 in (172 mm)
Wall
Bracket
3.3 in
(85 mm)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us