Rinnai ES38 RHFE-1004RFA, ES38 RHFE-1004FTA Conversion Manual

Page 1
Conversion Manual for the
ES38 (RHFE-1004RFA)
(RHFE-1004FTA)
Energysaver ®
Gas Direct Vent Wall Furnace
for the conversion from
Natural Gas (NG) to Liquid Propane Gas (LPG)
English
Technical Data ......................... 2
for the conversion from
Liquid Propane Gas (LPG) to Natural Gas (NG)
for adjustments at high altitude
(greater than 2000 ft / 610 m)
Conversion Procedure ............. 3
Parts List ................................ 11
Français
Données Techniques ............... 7
Haute Altitude Installtion .......... 7
Procédure de conversion ......... 8
Liste des Pièces ..................... 11
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
DANGER
WARNING
CAUTION
Safety Symbols
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices.
Page 2
Technical Data
Minimum supply gas pressure 5.0 in (127 mm) W.C. 11.0 in (280 mm) W.C.
Maximum supply gas pressure 10.5 in (267 mm) W.C. 13.0 in (330 mm) W.C.
Code
Altitude
Manifold test
pressure -
W.C. Low
Manifold test
pressure -
W.C. High
Natural Gas Propane Gas
BTU/hour input Low 10,500 High 38,400 Low 10,500 High 36,500
BTU/hour output Low 8,400 High 30,720 Low 8,400 High 29,200
Natural Gas Propane Gas
A1 A2 A3 A4 L1 L2 L3 L4
0-2000 ft
0-610 m
1.97 in
mm)
(50
3.7 in
mm)
(94
2001-5200 ft
611-1585 m
1.97 in
(50 mm)
3.3 in
(83 mm)
5201-7700 ft
1586-2347 m
1.97 in
(50 mm)
3.0 in
(76 mm)
7701-10200 ft
2348-3109 m
1.97 in
(50 mm)
2.8 in
(70 mm)
0-2000 ft
0-610 m
4.29 in
(109 mm)
10.1 in
(257 mm)
2001-5200 ft
611-1585 m
4.29 in
(109 mm)
9.1 in
(232 mm)
5201-7700 ft
1586-2347 m
4.29 in
(109 mm)
8.3 in
(212 mm)
7701-10200 ft
2348-3109 m
4.29 in
(109 mm)
7.6 in
(194 mm)
Burner Orifice - High
Burner Orifice - Low
Natural Gas Propane Gas
1004F-2031-B-1.80
0.071 in (1.80 mm)
1004F-2036-B-1.95
0.077 in (1.95 mm)
1004F-2031-A-0.95
0.037 in (0.95 mm)
1004F-2036-A-1.20
0.047 in (1.20 mm)
Front Right Left Front Right Left
Damper Adjustment
7/10 10/10 10/10 10/10 10/10 10/10
The input rate can be verified by following the procedure in the National Fuel Gas Code (NFPA54 / ANSI Z223.1, 2006 or latest edition).
High Altitude Installation
Conversion of the appliance for operation at high altitudes (> 2000 ft, 610 m) requires the completion of the section, Adjust Gas Pressure Settings, using the high altitude manifold test pressures above. No parts need to be replaced for high altitude.
For high altitude installations in Canada, the conversion shall be carried out by a manufacturer’s authorized representative, in accordance with the requirements of the manufacturer, provincial or territorial authorities having jurisdiction and in accordance with the requirements of CAN/CGA-B149.1 or CAN/CGA-B149 installation codes.
2 Rinnai Corporation ES38 Conversion Manual
Page 3
Conversion Procedure
CAUTION
Confirm that the inlet gas pressure is between the minimum and maximum pressures allowed for this appliance.
1. Remove 2 screws that hold the front panel in place.
2. Pull panel forward from the top of unit out about 3 inches. Reach inside electrical compartment and unplug the indicator lamp assembly. Lift panel up and set it off the unit. Remove both side panels.
3. Remove all 3 gas tubes from the unit. Be careful not to lose the O-rings on each end of the gas tubes. Always ensure there is an O-ring in each port of the gas valve and in each of the orifices before reinstalling gas tubes.
4. Replace all 3 burner orifices with the proper size required for gas type being used. Refer to the Technical Data section.
NOTICE
The low fire orifice has a longer shoulder than the high fire orifices. When converting products, please ensure all instructions are followed. You must readjust manifold gas pressure on the appliance following manufacturer’s instructions and replace all 3 burner orifices and rest air shutters. Failure to follow the manufacturer’s instructions may result in damage to the unit. If you have not been properly trained on converting this product, please do not proceed. Contact a qualified service agency to perform conversion.
The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
5. Propane gas unit air shutter settings: Loosen set screw on air adjustment rods. Adjust all 3 air shutters to 100% air, no notches will be showing on the rods when adjusted correctly. The air rods can be found directly under each gas line at the combustion chamber. Retighten set screw once adjustments have been made.
Natural gas unit air shutter settings:
Loosen set screw on air adjustment rods. Adjust the right rear and left hand air shutters to 100% air, no notches will be showing on the rods when adjusted correctly. Adjust the right front air shutter to where 3 notches are showing - this is 70% air. The air rods can be found directly under each gas line at the combustion chamber. Retighten set screw once adjustments have been made.
Rinnai Corporation ES38 Conversion Manual 3
6. Ensure all 3 gas tubes have been reinstalled and tightened. Leak test all gas tube connections to ensure O-rings were reinstalled and all fittings have been retightened.
7. Gas pressure must be readjusted when converting form one gas type to the other. Follow the procedure, Adjust Gas Pressure Settings.
Page 4
Adjust Gas Pressure Settings
CAUTION
Do not touch any other areas on the PC board besides the “SW” switches while power is supplied to the appliance. Parts of the PC board are supplied with 120 volts AC.
CAUTION
Do not insert hands or objects into the circulation fans while they are running. Injury or mechanical malfunction may occur.
CAUTION
Do not touch the areas at or near the exhaust. This area becomes very hot and could cause burns.
1. Turn off the gas and the power supply.
2. Remove one test point screw (1/8 NPT tap) with 3/16 Allen wrench and attach the manometer to the test port. Ensure that the manometer is properly calibrated.
3. Turn on the gas and power supply to the appliance. With the unit in the Off position, press the SW1 switch at the top of PC board until it beeps.
4. Select the correct code for gas type and altitude on the LED display using and buttons:
L1: Propane gas below 2000 ft (610 m) L2: Propane gas 2001-5200 ft (611-1585 m)
L3: Propane gas 5201-7700 ft (1586-2347 m) L4: Propane gas 7701-10200 ft (2348-3109 m) A1: Natural gas below 2000 ft (610 m) A2: Natural gas 2001-5200 ft (611-1585 m) A3: Natural gas 5201-7700 ft (1586-2347 m) A4: Natural gas 7701-10200 ft (2348-3109 m)
5. Press the SW1 switch to enter the gas code into memory.
The LED display turns blank and the unit returns
to the normal off mode. You are now ready to program in your correct low fire and high fire gas pressure setting. Follow the procedure below for setting the manifold gas pressure. Do not adjust gas pressure on this appliance using the screw on top of the gas valve.
6. Press the ON/OFF button to operate the appliance.
7. Press the SW1 switch. The LED will display two digits - a “7” and another number.
Display
Te m p
Time
8. Press the SW1 switch again to change to the low pressure mode. The LED will display “PL”.
9. Compare the pressure reading on the manometer to the correct table for your gas type. If necessary adjust the low fire pressure using the and buttons. Press the Economy switch to record into
4 Rinnai Corporation ES38 Conversion Manual
Page 5
Adjust Gas Pressure Settings
memory. Press the SW1 switch twice.
10. The LED will display “PH” indicating high fire mode.
11. Compare the pressure reading on the manometer to the correct table for your gas type. If necessary adjust the high fire pressure using the and buttons. Press the Economy switch to record into memory.
12. The LED will display two digits - a “7” and another number. If the LED shows any thing else call Rinnai Technical Support at 1-800-621-9419 for assistance.
13. Press the ON/OFF button again. The LED display turns blank and the appliance returns to the normal OFF mode.
14. Remove manometer and install Allen head screw. Operate the unit and
check the normal operating sequence
visually inspect the flame
check for gas leaks at the test points
NOTE: If the LED display shows “HF” or “LF” do not
touch the and buttons or Economy button. In this case push SW1.
Normal Operating Sequence
When you press the ON/OFF button, the LED display will illuminate, the combustion fan will begin to run, and the spark will ignite the main burner.
This heater has an automatic ignition system. When the main burner has lit, the combustion lamp will glow red, and the spark will stop.
Visual Inspection of Flame
Check that the burner flames are operating normally. The flame can be seen through the circular window through the louvers.
When operating normally the burner flame should appear as long, clear, blue, stable, streaks. Yellow flames or an orange color is abnormal and maintenance is required.
Final Assembly
1. Install the front panel and bottom cover.
NOTICE
The regulator has been factory pre-set. If the pressure is incorrect, check the supply pressure first, before making any adjustments to the appliance. Also, if the low control pressure cannot be obtained, adjust the adjustment screw on the proportional valve to roughly set pressure and then recheck both the low and high fire pressures.
2. Place the conversion plate (label) on the front cover.
Rinnai Corporation ES38 Conversion Manual 5
Page 6
Manuel de Conversion pour
ES38 (RHFE-1004RFA)
(RHFE-1004FTA)
Chauffage au gaz à ventilation directe
avec économiseur d’énergie
pour la conversion du
gaz propane au gaz
English
Technical Data ......................... 2
naturel
pour la conversion du
gaz naturel au gaz propane
High Altitude Installaton ............ 2
Conversion Procedure .............. 3
Parts List ................................ 11
Français
pour réglage en haute
altitude (greater than 2000 ft / 610 m)
Données Techniques ............... 7
Haute Altitude Installtion ........... 7
Procédure de conversion .......... 8
Liste des Pièces ..................... 11
AVERTISSEMENT
Cette trousse de conversion doit être installée par un technician agréé, selon les instructions du fabricant et selon toutes les exigences et tous les codes pertinents de l’autorité compétente. Assurezvous de bien suivre les instructions dans cette notice pour réduire au minimum le risqué d’incendie, d’explosion ou la production de monoxyde de carbone pouvant causer des dommages matériels, des blessures ou la mort. Le technician agréé est responsible de l’installation de cette trousse. L’installation n’est pas adéquate ni compléte tant que le bon fonctionnement de l’appareil converti n’a pas été vérifié selon les instructions du fabricant fournies avec la trousse.
Sécurité Du Consommateur
Ceci est un symbole relatif à la sécurité. Il vous prévient de dangers potentiels qui peuvent tuer ou blesser vous et d'autres.
DANGER
AVERTISSEMENT ATTENTION
6 Rinnai Société ES38 Manuel de Conversion
Indication d’une situation imminente dangereuse, qui si elle n’est pas évitée peut en­traîner des blessures graves voire mortelles.
Indication d’une situation potentiellement dangereuse, qui si elle n’est pas évitée peut entraîner des blessures légères ou moyennes. On peur également l’utiliser pour signaler des pratiques non sûres.
Indication d’une situation potentiellement dangereuse, qui si elle n’est pas évitée peut entraîner des blessures graves voire mortelles.
Page 7
Données Techniques
Gaz Naturel Gaz Propane
Pression d’alimentation de gaz - Minimum 5.0 in (127 mm) W.C. 11.0 in (280 mm) W.C.
Pression d’alimentation de gaz - Maximum 10.5 in (267 mm) W.C. 13.0 in (330 mm) W.C.
BTU/heure consommation Bas 10,500 Haut 38,400 Bas 10,500 Haut 36,500
BTU/heure rendement Bas 8,400 Haut 30,720 Bas 8,400 Haut 29,200
Code
Altitudes
Pression differ-
entielle du col-
lecteur - W.C.
Bas
Pression differ-
entielle du col-
lecteur - W.C.
Haut
A1 A2 A3 A4 L1 L2 L3 L4
0-2000 ft
0-610 m
1.97 in
(50 mm)
3.7 in
(94 mm)
Gaz Naturel Gaz Propane
2001-5200 ft
611-1585 m
1.97 in
(50 mm)
3.3 in
(83 mm)
5201-7700 ft
1586-2347 m
1.97 in
(50 mm)
3.0 in
(76 mm)
7701-10200 ft
2348-3109 m
1.97 in
(50 mm)
2.8 in
(70 mm)
0-2000 ft
0-610 m
4.29 in
(109 mm)
10.1 in
(257 mm)
2001-5200 ft
611-1585 m
4.29 in
(109 mm)
9.1 in
(232 mm)
5201-7700 ft
1586-2347 m
4.29 in
(109 mm)
8.3 in
(212 mm)
7701-10200 ft
2348-3109 m
4.29 in
(109 mm)
7.6 in
(194 mm)
Orifice du Bruleur - Haut
Orifice du Bruleur - Bas
Gaz Naturel Propane Gas
1004F-2031-B-1.80
0.071 in (1.80 mm)
1004F-2036-B-1.95
0.077 in (1.95 mm)
1004F-2031-A-0.95
0.037 in (0.95 mm)
1004F-2036-A-1.20
0.047 in (1.20 mm)
Avant Droit Gauche Avant Droit Gauche
Reglage Amortisseur
7/10 10/10 10/10 10/10 10/10 10/10
Le débit de gaz peut être vérifié par après le procédé dans National Fuel Gas Code (NFPA54 / ANSI Z223.1, 2006 ou la dernière édition).
Le bon renedement représente 80% de la consommation estimée pour les installations canadiennes.
Haute Altitude Installation
La conversion de l'appareil pour l'opération aux hautes altitudes (> 2000 ft, 610 m) exige l'achèvement de la section, Ajuster les Cadres de Pression de Gaz, utilisant l'haute altitude les pressions de test diverses au-dessus. Aucunes parties ont besoin d'être remplacé.
Pour des installations d'altitude élevée au Canada, la conversion doit être effectuée en suivant les conditions requises par les autorités des provinces ayant jurisdiction et conformément aux exigences 1 et 2 du Code d’Installation CAN1-B149.
Rinnai Société ES38 Manuel de Conversion 7
Page 8
Procédure de Conversion
ATTENTION
Confirmer que la pression de gaz d'arrivée est entre les pressions de minimum et maximum a tenu le compte de cet appareil
Avant d’effectuer la conversion, couper d’abord l’alimentation en gaz, ensuite, couper l’alimentation électrique.
8 Rinnai Société ES38 Manuel de Conversion
Page 9
Ajustage et Reglage de la Presion de Gas
ATTENTION
Ne pas toucher aucuns autres secteurs sur le conseil de PC outre les commutateurs de « SW » pendant que le pouvoir est fourni à l'appareil. Les parties du conseil de PC sont fournies avec 120 volts.
ATTENTION
Ne pas toucher le secteur à près de l'échappement. Ce secteur devient très chaud et pourrait causer des brûlures.
1. Arrêtez l'alimentation de gaz et d'énergie.
2. Retirez le taraud de test 1/8 NPT avec une clé à 6 pans de 3/16 et raccordez le manomètre de pression.
3. Allumer le gaz et l'alimentation à l'appareil. Avec l'unité dans le De la position, appuyer le SW1 commutateur en haut du conseil de PC jusqu'à ce qu'il sonne.
4. Choisir le code correct sur l'utilisation d'exposition et boutonne:
L1: Le gaz de propane en-dessous 2000 ft ((610
m)
L2: Le gaz de propane 2001-5200 ft (611-1585 m) L3: Le gaz de propane 5201-7700 ft (1586-2347 m) L4: Le gaz de propane 7701-10200 ft (2348-3109
m)
A1: Le gaz naturel en-dessous 2000 ft (610 m) A2: Le gaz naturel 2001-5200 ft (611-1585 m) A3: Le gaz naturel 5201-7700 ft (1586-2347 m) A4: Le gaz naturel 7701-10200 ft (2348-3109 m)
ATTENTION
N'insérez pas les mains ou les objets dans les ventilateurs de circulation tandis qu'ils fonctionnent. Les dommages ou le défaut de fonctionnement mécanique peuvent se produire.
écran
5. Appuyer le SW1 commutateur pour entrer l'échelle de température dans la mémoire.
Le vide ÉCRAN de virages d'exposition et l'unité
retournent au normal du mode. Pendant que programmant le feu bas correct et les hauts cadres de pression de gaz de feu, ne pas ajuster la pression de gaz sur cet appareil utilisant la vis sur la soupape de gaz.
6. Appuyer l'interrupteur pour fonctionner l'appareil.
7. Appuyer le SW1 commutateur. L'affichage montrera à deux chiffres - un « 7 » et un autre numéro.
8. Appuyer le SW1 commutateur encore pour changer au mode de pression bas. Le ÉCRAN affichera «PL».
9. Comparer la pression lisant sur le manomètre aux Données Techniques, le niveau bas de pression de test divers, pour le gaz étant utilisé. Si nécessaire ajuster la pression basse de feu utilisant le et boutons. Appuyer le Economy commutateur. Appuyez deux fois sur le commutateur SW1.
10. Le ÉCRAN affichera « PH ».
Rinnai Société ES38 Manuel de Conversion 9
Te m p
Time
Page 10
Ajustage et Reglage de la Presion de Gas
11. Comparer la pression lisant sur le manomètre aux Données Techniques, la pression de test diverse ­haut, pour le gaz étant utilisé. Si nécessaire ajuster l'haute pression de feu utilisant le et boutons. Appuyer le Economy commutateur.
12. L'affichage montrera à deux chiffres - un « 7 » et un autre numéro. Si l'affichage montre autre chose avec Rinnai pour assistance (1-800-621-
9419).
13. Appuyer l'interrupteur encore. Le vide ÉCRAN de virages d'exposition et l'appareil retournent au normal du mode.
14. Enlever le manomètre et installer les vis de tête d'Allen. Fonctionner l'unité et
vérifier la séquence normale d'opération
visuellement inspecter la flamme
le contrôle pour gaze des fuites aux points
de test
Remarque : Si l'affichage LED montre « HF » ou « LF » ne pas toucher les boutons et ou le bouton de l'économie. Dans ce cas pousser SW1.
La Séquence normale d'Opération
Quand vous appuyez l'interrupteur, l'exposition ÉCRANE illuminera, le ventilateur de combustion commencera à courir, et l'étincelle allumera le brûleur principal. Cet appareil de chauffage a un système d'allumage automatique. Quand le brûleur principal a lit, la lampe de combustion luira rouge, et l'étincelle arrêtera.
L'Inspection visuelle de Flamme
Vérifier que les flammes de brûleur fonctionnent normalement. La flamme peut être vue par la fenêtre circulaire par le louvers.
En fonctionnant normalement la flamme de brûleur doit apparaître comme long, éclaircir, le bleu, l'écurie, les raies. Le jaune flambe ou une couleur orange est anormale et l'entretien est exigé.
Assemblée finale
1. Installer le panneau de devant et la couverture de fond.
2. Placer la plaque de conversion (l'étiquette) sur la couverture de devant.
REMARQUE
Le régulateur a été usine préréglée. Si la pression est incorrecte, vérifiez la pression d'approvisionnement d'abord, avant de faire tous les ajustements à l'appareil. En outre, si la basse pression de commande ne peut pas être obtenue, ajustez la vis d'approche sur la valve proportionnelle sur la pression rudement réglée et revérifiez alors les basses et élevées pressions du feu.
10 Rinnai Société ES38 Manuel de Conversion
Page 11
Parts List / Liste des Pièces
Part Name
Nom de la pi éce
Injector
(High)
Injecteur
(haut)
Injector
(Low)
Injecteur
(bas)
Injector
(High)
Injecteur
(haut)
Part No.
Numéro de piéce
1004F-2031-B-1.80
1004F-2036-B-1.95
1004F-2031-A-0.95
Gas
Gaz
NAT.
NAT.
LPG
Qty'
Quantité
2
1
2
Visual Reference
R éférence visuelle
Injector
(Low)
Injecteur
(bas)
Conversion Plate
Plaque de conversion
Conversion Plate
Plaque de conversion
1004F-2036-A-1.20
CP-72317-21
CP-72317-22
LPG
NAT.
LPG
1
1
1
Rinnai Société ES38 Manuel de Conversion 11
Page 12
© 2011 Rinnai America Corporation
RHFE1004-0329(00) Printed in Japan 2011.04