Flow Control ......................................................................................................................................... 8
The Digital Network Adapter (DNA200) interfaces an external RS232 or RS422 device to Ring Communications’
Crisis Alert System.
The DNA200 operates on +24 VDC. It can be powered from a fuse in the CB901 or RM5000 central exchange.
The recommended cord is the BF640A to connect the DNA200 to the RJ45 network jack, KB171. Cords and
jacks must be ordered separately .
RS422RS232RS485
12345612345678
5
J3J2J1
Rear Panel Connectors
J1 - 8 pin (RJ45) Network connections:
Two modular jacks are provided at the rear of the DNA200. Use modular cables with straight through pin
configuration only! An 8-pin (RJ45) modular jack (KB171) and cord (BF640A) are required for connection to the
network.
PIN# - DESIGNA TION
1 - No connection.
2 - +12 VDC power input
3 - Data + (positive)
4 - No connection.
5 - No connection.
6 - Data - (negative)
7 - -12 VDC power input
8 - External Alarm.
The maximum total network length is 7000 feet. A unshielded twisted pair cable should be used for the dat a pair (24
or 22 A WG).
Connect the DA T A pair from the network to pins 3 and 6 of the RJ45 wall jack maint aining polarity of the pair .
If a remote power source is being used, the negative side of the supply must be referenced to Earth Ground, as well
as, the CB901 power supply .
6
DNA200 OPERATIONS MANUAL
2008/05/01
J2 - 9 pin (DB9) RS232 signals :
The DNA200 has a RS232 serial port interface, J2, that can connect to a terminal, printer, or video switcher . Check
your terminal, printer or video switcher manual for the correct RS232 connector type, input, output and handshaking
signal connections.
The maximum length for a RS232 cable connecting the DNA200 and other equipment is 50 feet.
A null-modem (LapLink) cable can be used to connect a DNA200 and a PC computer together if they are close
enough to each other.
If you are going to make your own cable the following is a description of the pinout of the DB9 connector on the
DNA200.
J2SIGNALDIRECTION/
PIN#NAMEDESIGNA TION
1D CDData Carrier Detect, input.
2R X DReceive Data, input.
3T XDTransmit Data, output.
4D T RData T erminal Ready , output.
5G NDSignal Ground.
6DS RNot used.
7R T SRequest to Send, output.
8C T SClear to Send, input.
9R INot used.
J3 - 6 pin (RJ11) RS422 signals :
2008/05/01
A two twisted pair installation utilizing RS422 signals can be used to connect two devices up to 7000 feet apart.
A strap MUST be inst alled between RTS and CTS of J2 (DB9), in order to disable flow control for the RS422. To
do this, simply place a strap between pin 7 and pin 8 of J2. You could also solder this strap to a female DB9
connector with solder lugs on the rear, then insert it into the J2 connector.
DNA200 OPERATIONS MANUAL
7
RTS
CTS
RX-
TX+
TX-
RX+
7
8
RS232
J2
1
2
3
4
5
PTWISTED
PAIR
7000 FEET MAX.
RX-
TX+
PTWISTED
PAIR
TX-
RX+
RS422 Interconnection
6
RS422
J3
Setting Baud Rate / Selecting Device Type
RS422
DEVICE
8
DIP switches SW3-1 through SW3-6 are used to set the desired baud rate for the RS232 device. SW3-7 and
SW3-8 are not used.
SW3
Baud Rate 1 2 3 4 5 6 | 7 8_
19200 1 0 0 0 0 1 | 0 0
9600 1 0 0 0 1 0 | 0 0
4800 0 1 0 0 0 1 | 0 0
2400 0 1 0 0 1 0 | 0 0
1200 1 0 0 0 1 1 |
0=OFF
1=ON
DNA200 OPERATIONS MANUAL
2008/05/01
Flow Control
Hardware flow control is used (RTS/CTS). The DNA200 will send data only if CTS is high (LED on) from the
connected device. Parity , Data Bits and S top Bits are programmable (see configuration section).
Resetting Battery Ram
When the system is first installed the Battery Ram must be reset .
Procedure:
1. Set all 8 dip switches in SW2 to OFF.
2. Push and release the Reset Switch (SW1).
3. Wait for the Master LED to start blinking (indicates reset complete)
4. Set Network Address.
5. Push and release the Reset Switch (SW1).
Setting Network Addr ess
DIP switch SW2 is used to set the address of the DNA200. See SETTING NETWORK ADDRESS in the NETWORK
manual for a full description for setting the addresses.
2008/05/01
DNA200 OPERATIONS MANUAL
9
FRONT PANEL SWITCHES AND INDICATORS -
SWITCHES
SW1 -Reset. Creates a local reset for this node only .
SW2 -Node & Network Address
SW3 -RS232 Baud Rate
L.E.D.’s (left side, network)
RUN -Indicates the local processor in the DNA200 is running. Will illuminate after power up or reset.
MASTER -Will light steady if this node is the master on the network. There can only be one master on each
network. On power up, each device waits for a response from a master . If no response is received,
then this device will take over as a master . Therefore, the first device powered up will be the master .
TX -Transmit data to the Network. Will flash when the DNA200 sends data out on the Network. If the
Master LED is on, the TX LED will flash constantly. When the Master LED is off, TX will only flash
when transmitting to other devices.
RX -Receive data from the Network. Will flash when data is transmitted from another device to the
network. If the Master LED is on, the RX LED will flash when other devices respond to scanning
from the Master. When the Master LED is of f, the RX LED will flash constantly.
L.E.D.’s (right side, RS232)
RTS -Request to send. Output, indicates the DNA200 is ready to receive data from the RS232 device.
CTS -Clear to send. Input, illuminated when the RS232 device is ready to receive data from the DNA200.
TX -Transmit data. Output to RS232 device.
RX -Receive data. Input from RS232 device.
MAST ER
SW 2SW 3
1 2 3 4 5 6 7 8ON1 2 3 4 5 6 7 8
RUNRX R TS
ADDRESS
TX CTS
RESET
TX
RX
ON
BAUD RATE
Front panel indicators
10
DNA200 OPERATIONS MANUAL
2008/05/01
CONFIGURATION
Note! Not used with American Dynamics Alarm input.
One DNA100 and a PC is used for programming the DNA200. The DNA100 sets up a link between
the PC and the DNA200. The Configuration is done from the PC and the information is stored in battery
RAM in the DNA200. When the system is first installed the Battery RAM must be reset before the system
is configured (see page 8).
SYNTAX
TYPE FONTS
boldface type
cr
indicates user input
Courier font indicates output
COMMAND
The command consists of a command word plus one or more parameters.
The command may be entered on one line with the parameters separated by spaces.
>command par1 par2 par3
cr
The command may be entered in prompt mode with parameters separated by carriage return. The prompt
will indicate what type of parameter value is required.
>command
Prompt>par1
Prompt>par2
Prompt>par3
cr
cr
cr
cr
>
PROMPT
< >Angle brackets enclose input parameters.
$Hexadecimal value (default is decimal).
-Range of values may be entered.
..Periods indicate that only ONE value is required from the range of values.
*Wild card means all values in a range of values.
/Optional input selection separator .
2008/05/01
DNA200 OPERATIONS MANUAL
ERROR HANDLING
Misspelled command input will give the following error message:
Unknown Command
Parameter errors will print ERROR: and then prompt for the parameter again.
HELP
HELP COMMANDS
Help lists all help commands in the Configuration program. T ype HELP , H or ?.
>HELP
DNA200 Command Summary:
====== =======================
HHelp
?Help
LCNList Call Numbers
LSPList Switcher Protocol
STTY Set Serial Port Characteristics
SMASet Monitor Address
SCASet Camera Address
SPNSet Camera Preset Number
LTTY List Serial Port Characteristics
SSPSet Switcher Protocol
BAKBackup
>
cr
11
12
DNA200 OPERATIONS MANUAL
SERIAL PORT
Set Parity , Data bits, Stop bits for the serial port to the V ideo Switcher .
All intercom stations are assigned call numbers in the Ring intercom central exchange.
The DNA200 Camera Switcher interface assigns Monitor Address and Camera Address to the intercom
call numbers. This assignment is stored in the DNA200 and may bel listed with the command LCN from the
PC connected to the DNA100.
The call number may be 2,3 or 4 digit decimal.
The camera and monitor address may be 1,2 3 or 4 digit HEX.
The camera or monitor may be removed from a call number by entering 0 as the address.
>LCN
cr
Call Number <10-9999/*> : 100-110
Intercom Monitor Camera Camera
Call Number Address Address Preset
=========== ======= ======= ======
100 10
101 11
102 200
103 201
104 202
>
cr
MONITOR ADDRESS
Assign a video monitor to an intercom station.
PROGRAMMING
The following commands are used for this feature.
SMASet Monitor Address
LCNList Call Number
Example: Set monitor address for intercom call number 100 to address 10.
When a call is cancelled on the intercom system a string is sent to the switch containing the monitor number
and camera number 0. This will blank the monitor on some switchers. If a camera address is assigned to call
number 9999 then this camera address will be used to blank the monitor.
LOGIN, LOGOUT
Call number 9998 is reserved for Login activation. Monitor = User Number, Camera = Password.
1. Send Login (if 998 is programmed)
2. Send Monitor to Camera connect
3. Send Camera Preset (if programmed)
4. Send Logout (if 998 is programmed)
2008/05/01
DNA200 OPERATIONS MANUAL
PROGRAMMING EXAMPLE:
Master station 100, subscriber address 00 is using monitor 10.
Master station 101, subscriber address 01 is using monitor 1 1.
Sub station 105 is using camera 25.
Sub station 106 is using camera 26.
The DXC9XX is using network address 08.
The DNA200 is using network address 0C.
CB901/CA (DXC901) programming:
From the DNA100/PC select 7 - CONFIGURE from the main menu.
F=find DXC NETWORK ADDRESS 08, Subscriber address 00.
Set Video Switcher Address to 0C.
N=next and set Video Switcher Address to 0C for subscriber address 01.
Exit CONFIGURA TION
or
RM5000/CA(DXC910) programming:
From the DNA100/PC select 6 - COMMUNICA TIONS LINK from the main menu.
Enter 08 to select the DXC910.
Enter: SNA 100 3 0C
SNA 101 3 0C
15
DNA200 programming:
From the DNA100/PC select 6 - COMMUNICA TIONS LINK from the main menu.
Enter 0C to select the DNA200.
Enter: SMA 100 10
SMA 101 11
SCA 105 25
SCA 106 26
16
DNA200 OPERATIONS MANUAL
2008/05/01
BACKUP
Backup generates all programming commands required to restore the configuration of the DNA200.
These commands may be downloaded and stored in a file on the PC. This file can then be uploaded to
restore the configuration of the DNA200
PROGRAMMING
The following commands are used for this feature.
BAKBackup
Example:
>BAK
cr
Call Number <10..9999> : *
!
! BACKUP START: 2008/11/12
!
! DNA200 VERSION: 2008/05/01
!
SMA 100 10
SMA 101 11
SCA 102 200
SCA 103 201
SCA 104 202
SPN 104 1
STTY 5
SSP 2
!
! END OF TRANSFER
cr
2008/05/01
DNA200 OPERATIONS MANUAL
PELCO
INTERFACE
Use the PELCO Data Translator CM9760 with the PELCO Switcher .
The CM9760 accepts the American Dynamics Control strings (see next page).
17
18
DNA200 OPERATIONS MANUAL
2008/05/01
AMERICAN DYNAMICS
STANDARD PROTOCOL
This video switcher interface is used for systems with multiple Monitors and multiple Cameras.
The Network Address of the DNA200 is programmed for each Masterst ation/DAD104 using a video monitor. This
programming is done in the DXC901 or DXC910. No configuration is required for the sub stations with camera in
the DXC901/DXC910.
The monitor address and camera address for each call number is programmed in the DNA200 (see Configuration).
COMMUNICATION PROTOCOL
The device receiving from the DNA200 is setup in the following matter:
The interface is using RS232 between the baud rates of 1200-19200 bps (see SETTING BAUD RATE/DEVICE
TYPE SELECT earlier in this chapter).
Data bits, stop bits and parity is programmable (see Configuration),
Hardware flow control (RTS/CTS).
Software flow control (X-ON/X-OFF).
MESSAGE FORMA T
The message format is in the following sequence for output messages from the DNA200:
MONITOR ADDRESS-One or two characters ASCII number .
M-Monitor select command.
a-Command separator .
Camera Address-One, two, three or four characters ASCII number
#-Camera select command
PRESET NUMBER-Preset number (1-99)
\-Camera preset command
a-Command separator
<LF>-Line feed
<CR>-Carrage return
Examples (based on programming exsample at the end of configuration section):
If master station 100(monitor 10) answers a call (on the DAD104) from sub station 105(camera 25) the following
message is sent from the DNA200: 10Ma25#a<LF><CR>
If master station 101(monitor 1 1) answers a call (on the DAD104) from sub station 106(camera 26) the following
message is sent from the DNA200: 11Ma26#a<LF><CR>
If master station 100 disconnects the DNA200 sends: 10Ma0#a<LF><CR>
2008/05/01
DNA200 OPERATIONS MANUAL
19
AMERICAN DYNAMICS ALARM
INTERFACE
This video switcher interface is used for systems with single Monitor and multiple Cameras. It is
compatible with American Dynamics RS232 Alarm Input.
The Network Address of the DNA200 is programmed for the Masterst ation/DAD104 using the video monitor. This
programming is done in the DXC901 or DXC910. No configuration is required for the sub stations with camera.
No configuration is required for monitor and cameras in the DNA200.
The substations call number is used for the alarm number in the protocol.
COMMUNICATION PROTOCOL
The device receiving from the DNA200 must be setup in the following matter:
The interface is using RS232 between the baud rates of 1200-19200 bps (see SETTING BAUD RATE/DEVICE
TYPE SELECT earlier in this chapter).
8 data bits, 1 stop bit, no parity, hardware flow control (RTS/CTS).
MESSAGE FORMA T
The message format is in the following sequence for output messages from the DNA200:
ALARM NUMBER EVENT RS
ALARM NUMBER-Three Character ASCII Call number of intercom sub station with camera.
EVENT -One Character ASCII E = Sub station connecting to master station.
I = Sub station disconnecting from master station.
RS -One Character ASCII a = Message sep arator .
Examples:
1.Master station 100 answers call (on DAD104) from sub station 105: 105Ea
2.Master station 100 parks sub station 105: 105Ia
3.Master station 100 unparks sub station 105: 105Ea
4.Master station 100 cancels sub station 105: 105Ia
20
DNA200 OPERATIONS MANUAL
2008/05/01
VICON VIDEO SWITCHER
This video switcher interface is used for systems with multiple Monitors and multiple Cameras.
The Masterstation/DAD104 with the video monitor must be configured in the DXC/DXA with the network address
for the Video Switcher . The DNA200 must then be configured for all intercom stations with camera and/or
monitor.
COMMUNICATION PROTOCOL
The device receiving from the DNA200 is setup in the following matter:
The interface is using RS232 between the baud rates of 1200-19200 bps (see SETTING BAUD RATE/DEVICE
TYPE SELECT earlier in this chapter).
Data bits, stop bits and parity is programmable (see Configuration),
Hardware flow control (RTS/CTS).
MESSAGE FORMA T
The message format is in the following sequence for the DNA200:
<SOH>A###<CR><LF>From DNA200 (monitor select)
The DNA200 will retransmit a message if <SOH>?<CR> or <SOH>*<CR> is received instead of the expected
<SOH>$<CR>. If no response is received within 2.5 seconds the message is also retransmitted.
Maximum two retransmit for each message.
2008/05/01
DNA200 OPERATIONS MANUAL
21
PANASONIC
PROTOCOL
WJ-SX550A
This video switcher interface is used for systems with multiple Monitors and multiple Cameras.
The Network Address of the DNA200 is programmed for each Masterst ation/DAD104 using a video monitor. This
programming is done in the DXC901 or DXC910. No configuration is required for the sub stations with camera in
the DXC901/DXC910.
The monitor address and camera address for each call number is programmed in the DNA200 (see Configuration).
COMMUNICATION PROTOCOL
The device receiving from the DNA200 is setup in the following matter:
The interface is using RS232 between the baud rates of 1200-19200 bps (see SETTING BAUD RATE/DEVICE
TYPE SELECT earlier in this chapter).
Data bits, stop bits and parity is programmable (see Configuration),
Hardware flow control (RTS/CTS).
Software flow control (X-ON/X-OFF).
MESSAGE FORMA T
The message format is in the following for output messages from the DNA200:
<STX>CMD:Wi-p<ETX>
<STX>CMD:H###CS####<ETX>
<STX>CMD:HLG<ETX>
<STX> Start of text (hex 02)
CMD:W Login command (see page 140)
CMD:HLG Logout comman
CMD:H Monitor select command
i = user number
p = password
CSCamera select command
## #Monitor address 1-3 digit numeric
####Camera address 1-4 digit numeric
<ETX> End of text (hex 03)
Message format from Panasonic:
<ACK> Message accepted (hex 06 = ctrlF)
This video switcher interface is used for systems with multiple Monitors and multiple Cameras.
The Network Address of the DNA200 is programmed for each Masterst ation/DAD104 using a video monitor. This
programming is done in the DXC901 or DXC910. No configuration is required for the sub stations with camera in
the DXC901/DXC910.
The monitor address and camera address for each call number is programmed in the DNA200 (see Configuration).
COMMUNICATION PROTOCOL
The device receiving from the DNA200 is setup in the following matter:
The interface is using RS232 between the baud rates of 1200-19200 bps (see SETTING BAUD RATE/DEVICE
TYPE SELECT earlier in this chapter).
Data bits, stop bits and parity is programmable (see Configuration),
Hardware flow control (RTS/CTS).
MESSAGE FORMA T
The message format is in the following for output messages from the DNA200 (ASCII):
Message format from AutoPatch:
Echo of all charcters received.
The DNA200 will wait for the echo T before sending more commands.
If the T is not recived within 2.5 seconds the command is aborted and ASCII X is sent to the switcher .
2008/05/01
DNA200 OPERATIONS MANUAL
23
ROBOT
PROTOCOL
MV16P-30
This video switcher interface is used for systems with single Monitor with multiple multiplexers with 16
cameras on each multiplexer.
The Network Address of the DNA200 is programmed for the Masterst ation/DAD104 using the video monitor. This
programming is done in the DXC901 or DXC910. No configuration is required for the sub stations with camera in
the DXC901/DXC910.
The camera address for each call number is programmed in the DNA200 (see Configuration).
The camera address is a 4 digit number. The first 2 digits are used to define the multiplexer (01-16) and the last
2 digits are used to define the camera (01-16) connected to the multiplexer.
Example: Camera address 01 12 is programmed in configuration for one of the intercom call numbers.
This camera is now assigned to multiplexer 1 input 12
COMMUNICATION PROTOCOL
The device receiving from the DNA200 is setup in the following matter:
The interface is using RS232 between the baud rates of 1200-19200 bps (see SETTING BAUD RATE/DEVICE
TYPE SELECT earlier in this chapter).
Data bits, stop bits and parity is programmable (see Configuration),
Hardware flow control (RTS/CTS).
MESSAGE FORMA T
The message format is in the following for output messages from the DNA200:
Connect message:1 character multiplexer address / 2 character camera address
Disconnect message:1 character hex (00)
Multiplexer address1 character (hex 01-16)
/1 character (hex 2F)
Camera address2 characters ASCII 01-16
24
DNA200 OPERATIONS MANUAL
2008/05/01
VIDEOBLOX
PROTOCOL
This video switcher interface is used for systems with multiple Monitors and multiple Cameras.
The Network Address of the DNA200 is programmed for each Masterst ation/DAD104 using a video monitor. This
programming is done in the DXC901, DXC910 or EX500. No configuration is required for the sub stations with
camera in the DXC901/DXC910/EX500.
The monitor address and camera address for each call number is programmed in the DNA200 (see Configuration).
COMMUNICATION PROTOCOL
The device receiving from the DNA200 is setup in the following matter:
The interface is using RS232 with baud rate of 9600 bps (see SETTING BAUD RATE/DEVICE TYPE SELECT
earlier in this chapter).
8 Data bits, 1 stop bits and no parity (see Configuration),
Hardware flow control (RTS/CTS).
MESSAGE FORMA T
The message format is in the following sequence for output messages from the DNA200:
Monitor Address .......One, two, three or four characters ASCII number
Preset Number .........One character ASCII number
<CR> ......................Carrage return
Examples (based on programming exsample at the end of configuration section):
If master station 100(monitor 10) answers a call (on the DAD104) from sub station 105(camera 25) the following
message is sent from the DNA200: SWITCH 25,10<CR>
If master station 101(monitor 1 1) answers a call (on the DAD104) from sub station 106(camera 26) the following
message is sent from the DNA200: SWITCH 25,11<CR>
If master station 100 disconnects the DNA200 sends: SWITCH 0,10<CR>
2008/05/01
DNA200 OPERATIONS MANUAL
25