RIGOL MSO5204, MSO5104, MSO5074, MSO5072, MSO5102 Quick Guide

...
English
中文
Quick Guide
MSO5000 Series
Digital Oscilloscope
May. 2020
RIGOL TECHNOLOGIES CO., LTD.
RIGOL
MSO5000 Quick Guide 1
English
Guaranty and Declaration
Copyright
© 2020 RIGOL TECHNOLOGIES CO., LTD. All Rights Reserved.
Trademark Information
RIGOL® is the trademark of RIGOL TECHNOLOGIES CO., LTD.
Publication Number
QGA25103-1110
Notices
RIGOL products are covered by P.R.C. and foreign patents, issued and
pending.
RIGOL reserves the right to modify or change parts of or all the
specifications and pricing policies at the company’s sole decision.
Information in this publication replaces all previously released materials. Information in this publication is subject to change without notice. RIGOL shall not be liable for either incidental or consequential losses in
connection with the furnishing, use, or performance of this manual, as well as any information contained.
Any part of this document is forbidden to be copied, photocopied, or
rearranged without prior written approval of RIGOL.
Product Certification
RIGOL guarantees that this product conforms to the national and industrial standards in China as well as the ISO9001:2015 standard and the ISO14001:2015 standard. Other international standard conformance certifications are in progress.
Contact Us
If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Website: www.rigol.com
RIGOL
2 MSO5000 Quick Guide
English
General Safety Summary
1. Only the exclusive power cord
designed for the instrument and authorized for use within the local country could be used.
2. Ensure that the instrument is
safely grounded.
3. Observe all terminal ratings.
4. Use proper overvoltage
protection.
5. Do not operate without covers.
6. Do not insert objects into the
air outlet.
7. Use the proper fuse.
8. Avoid circuit or wire exposure.
9. Do not operate the instrument
with suspected failures.
10. Provide adequate ventilation.
11. Do not operate in wet conditions.
12. Do not operate in an explosive
atmosphere.
13. Keep instrument surfaces clean
and dry.
14. Prevent electrostatic impact.
15. Handle with caution.
Safety Notices and Symbols
Safety Notices in this Manual:
WARNING
Indicates a potentially hazardous situation or practice which, if not avoided, will result in serious injury or death.
CAUTION
Indicates a potentially hazardous situation or practice which, if not avoided, could result in damage to the product or loss of important data.
Safety Terms on the Product:
DANGER
It calls attention to an operation, if not correctly performed, could result in injury or hazard immediately.
WARNING
It calls attention to an operation, if not correctly performed, could result in potential injury or hazard.
CAUTION
It calls attention to an operation, if not correctly performed, could result in damage to the product or other devices connected to the product.
RIGOL
MSO5000 Quick Guide 3
English
Safety Symbols on the Product:
Hazardous
Voltage
Safety
Warning
Protective Earth
Terminal
Chassis Ground
Test Ground
Care and Cleaning
Care
Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time.
Cleaning
Clean the instrument regularly according to its operating conditions.
1. Disconnect the instrument from all power sources.
2. Clean the external surfaces of the instrument with a soft cloth dampened
with mild detergent or water. Avoid having any water or other objects into the chassis via the heat dissipation hole. When cleaning the LCD, take care to avoid scarifying it.
CAUTION
To avoid damage to the instrument, do not expose it to caustic liquids.
WARNING
To avoid short-circuit resulting from moisture or personal injuries, ensure that the instrument is completely dry before connecting it to the power supply.
Document Overview
This manual gives you a quick review about the front and rear panel of MSO5000 series, the user interface, and the basic operation method.
Tip
For the latest version of this manual, download it from the official website of RIGOL (www.rigol.com).
RIGOL
4 MSO5000 Quick Guide
English
Format Conventions in this Manual
1. Key
The key on the front panel is denoted by the format of "Key Name (Bold) + Text Box" in the manual. For example, Utility denotes the "Utility" key.
2. Menu
The menu items are denoted by the format of "Menu Word (Bold) + Character Shading". For example, System denotes the "System" menu item under Utility.
3. Operation Procedures
→ denotes the next step of operation. For example, UtilitySystem denotes that first press Utility, and then press the System softkey.
4. Knob
Label
Knob
Label
Knob
Horizontal SCALE
Horizontal Time Base Knob
Vertical SCALE
Vertical Scale Knob
Horizontal POSITION
Horizontal Position Knob
Vertical OFFSET
Vertical Offset Knob
Trigger LEVEL
Trigger Level Knob
Multifunction Knob
Content Conventions in this Manual
MSO5000 series includes the following models. Unless otherwise specified, this manual takes MSO5354 as an example to illustrate the functions and operation methods of MSO5000 series digital oscilloscope.
Model
Analog Bandwidth
No. of Analog Channels
No. of Function/Arbitrary Waveform Generator Channels
No. of Digital Channels
MSO5072
70 MHz
2
2, Opt.
16
MSO5074
70 MHz
4
2, Opt.
16
MSO5102
100 MHz
2
2, Opt.
16
MSO5104
100 MHz
4
2, Opt.
16
MSO5204
200 MHz
4
2, Opt.
16
MSO5354
350 MHz
4
2, Opt.
16
RIGOL
MSO5000 Quick Guide 5
English
General Inspection
1 Inspect the packaging
If the packaging has been damaged, do not dispose the damaged packaging or cushioning materials until the shipment has been checked for completeness and has passed both electrical and mechanical tests.
The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument.
2 Inspect the instrument
In case of any mechanical damage, missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
3 Check the accessories
Please check the accessories according to the packing lists. If the accessories are damaged or incomplete, please contact your RIGOL sales representative.
Product Overview
The MSO5000 series is a high-performance digital oscilloscope designed on the basis of the RIGOL UltraVision II technology. It has a 9-inch capacitive touch screen, and integrates 7 instruments into one. With a compact and portable design, it delivers excellent specifications, such as super high sample bandwidth ratio and high memory depth. All the MSO5000 series support multiple channels, bandwidths, and the upgrade of the analysis software. They integrate the functions of multiple instruments. Different user groups can have more choices in selecting their desired product based on their needs, helping them save their budget to a large extent while enjoying the superior test support and user experience.
For descriptions of the front panel, refer to Figure 1 and Table 1; for descriptions of the rear panel, refer to Figure 2 and Table 2; and for descriptions of the main interface (display screen), refer to Figure 3 and Table
3.