RIGOL MC3416 Users guide

Modules/Terminal Block Supported by M300
Module Terminal Block Description
MC3065 doesn't need
terminal block
DMM-MC3065
M300
Series
Data Acquisition/ Switch System
·DMM module
·6½ digits
·Support the following functions: DCV, ACV, DCI, ACI, 2WR, 4WR, FREQ, PERIOD, TEMP and any sensor
·After connecting the DMM module, make sure that the signal under test connected to the analog bus is no greater than 300 Vdc or 300 Vrms
·20-channel multiplexer
·All 20 channels switch both HI and LO inputs
·Support 4-wire measurement
·The signal to be tested is connected through the M3TB20 terminal block
·Can be connected with MC3065
MUX20-MC3120 M3TB20
MUX32-MC3132 M3TB32
MUX64-MC3164 M3TB64
MIX24-MC3324 M3TB24
·32-channel multiplexer
·All 32 channels switch both HI and LO inputs
·Support 4-wire measurement
·The signal to be tested is connected through the M3TB32 terminal block
·Can be connected with MC3065
·64-channel single-ended multiplexer
·All 64 channels can switch HI input only
·Doesn't support 4-wire measurement
·The signal to be tested is connected through the M3TB64 terminal block
·Can be connected with MC3065
·Mixed multiplexer with 20 voltage channels and 4 current channels
·All 20 voltage channels switch both HI and LO inputs
·20 voltage channels support 4-wire measurement
·4 current channels are used to measure DC current or
AC current
·The signal to be tested is connected through the M3TB24 terminal block
·Can be connected with MC3065
1
RIGOL
ACT-MC3416 M3TB16
MFC-MC3534 M3TB34
·16-channel actuator
·Can connect signal to the device under test or enable external device
·Any of the 16 channels can switch to Normally-Open (NO) and Normally-Closed (NC) states
·The signal is connected through the M3TB16 terminal block
·Multifunction module
·DIO: four 8-bit digital input/output ports
·TOT: four totalizer input terminals
·DAC: four analog output terminals
·The signal is connected through the M3TB34 terminal block
·4×8 two-wire matrix switch
·Used to connect multiple devices to multiple points on
the device under test
·32 two-wire cross points which can connect any
combination of inputs and outputs at the same time
·The signal is connected through the M3TB48 terminal block
MATRIX-MC3648
M3TB48
RIGOL
2
Multiplexers Selection Guide
M300 provides ve kinds of multiplexers and ve kinds of external terminal blocks which are used to connect signals. These multiplexers support three types of connection modes: 1-wire mode, 2-wire mode and 4-wire mode. You can select your desired multiplexer and terminal block by referring to the following table.
MC3120 MC3132 MC3164 MC3324
20 32 64 20+4
Number of Channels
Scan Speed 60Ch/s 60Ch/s 60Ch/s 60Ch/s
Terminal Block M3TB20 M3TB32 M3TB64 M3TB24
DC Voltage
AC Voltage
DC Current
AC Current
2WR
4WR
Frequency
Period
TC
Temperature
Any Sensor
RTD
RTD 4W
Thermistor
DC Voltage
DC Current
2WR
4WR
Frequency
2-wire mode or 4-wire
mode
2-wire mode or 4-wire
mode
1-wire mode
2-wire mode or 4-wire
mode
MC3120 20-Channel Multiplexer
20-channel multiplexer
·
All 20 channels switch both HI and LO inputs
·
Support 4-wire measurement
·
The signal to be tested is connected through the M3TB20 terminal block
·
Can be connected with MC3065
·
3
RIGOL