RIGOL DSA832-TG, DSA832, DSA875-TG, DSA875, DSA815 QuickStart Guide

...
RIGOL
快速指
系列频谱分析仪
DSA800
Quick Guide
© 2014 RIGOL TECHNOLOGIES, INC. All Rights Reserved.
DSA800
DSA800 Series Spectrum Analyzer

General Safety Summary

1. Use power cords designed for the instrument and authorized by local country.
2. Make sure the instrument is grounded properly .
3. Do not operate without covers.
4. Use proper fuse.
5. Avoid circuit or wire exposure.
6. Do not operate with suspected failures.
7. Keep proper ventilation.
8. Do not operate in wet conditions.
9. Do not operate in flammable and explosive environment.
10. Keep product surface clean and dry.
11. Protect the instrument from static electricity.
12. Pay attention to handling saf ety.
-7-
Preset LCD Menu Softkeys/Menu Control Keys Function Keys Knob
Print Direction
Numeric

Product Overview

DSA800 series spectrum analyzers which are small, light and cost-effective, are portable spectrum analyzers de signed for starters. It mainly includes DSA815, DSA832 and DSA875 three models. Configured with easy-to-operate keybo ar d, high-resolution color LCD display and various remote communication interfaces, they can be widely used in various fields, such as education, company research and development as well as industrial manufacture.
Keys
Help
Keyboard
Power Switch USB Host Earphone Jack TG Output RF Input
USB Device LAN TRIGGER IN 10MHz OUT 10MHz IN
AC Connector Fuse Seat Handle Security Lock Hole
-8-
CAUTION
grounded to avoid electric shock.
Unfold the Supporting Legs

To Adjust the Supporting Legs

Users can unfold the supporting legs to use them as stands to tilt the instrument upwards for easier operation and observation. Users can also fold the supporting legs when the instrument is not in use for easier storage or shipment.
Fold the Supporting Legs

To Connect Power

Connect the spectrum analyzer to AC power source using the power cord supplied with the accessories. DSA800 supports 100 V - 240 V, 45 Hz - 440 Hz AC power source and 5 mm×20 mm, 250V AC, T2A fuse.
Make sure that the instrument is properly

Start-up and Self-calibration

After connecting the instrument to power source correctly, press
at the front panel to start the spectrum analyzer. You can obtain information about the start-up initialization process through the start-up progress indications. Following the start-up screen, the sweep curve is displayed. Press System Calibrate  Cal Now and the instrument will perform self-calibration using the internal calibration source (for more information, refer to the
DSA800 Series User’s Guide
-9-
).
CAUTION
reverse DC voltage cannot exceed 50 V.
CAUTION
respectively.

Using Notices

1. To use the tracking generator output terminal:
To avoid damage to the tracking
2. To use the RF input terminal:
generator, the reverse power cannot exceed +10 dBm when the frequency less than 10 MHz; the reverse power cannot exceed +20 dBm when the frequency more than 10 MHz. The
To avoid damage to the instrument, for the signal input from the RF input terminal, the DC voltage component and the maximum continuous power of the AC (RF) signal component cannot exceed 50 V and +20 dBm

Remote Control Overview

DSA800 supports communication with PC via USB, LAN or GPIB (option) interfa ce for remote control. The remote control is realized on the basis of SCPI (Standard Commands for Programmable Instruments) command set through two ways: user-defined programming and PC software (such as RIGOL Ultra Sigma). When the instrument is in remote mode, the
icon is displayed in the user interface and the front panel keys (except Esc) are locked. At this point, you can press Esc to exit remote mode.
-10-
Z
N1020002759

For More Product Information

You can ob tain t he ins tr ument inform a ti on including model, serial number as well as har d war e an d so f twar e ver sio n numbers through SystemInformation  System Info. You can also view the list of installed options through System
License. For more information of this product, please refer to the following manuals (you can download them from the RIGOL network): DSA800 Series User’s Guide: provide detailed introductions of the functions of this product; DSA800 Series Programming Guide: provide detailed introductions of the SCPI commands and progra mm ing of this product; DSA800 Series Datasheet: provide the main characteristics and specifications of this product; DSA800 Series Accessories and Options: provide detailed introductions of the accessories and options of this product.

Contact Us

If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Websites: www.rigol.com