Rigol DSA700 series, DSA710, DSA705 User Manual

Page 1
RIGOL
User’s Guide
DSA700 Options and Acce ssories
Jun. 2016
RIGOL TECHNOLOGIES, INC.
Page 2
Page 3
RIGOL
DSA700 Options and Accessories
I
Guaranty and Declaration
Copyright
© 2016 RIGOL TECHNOLOGIES, INC. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL TECHNOLOGIES, INC.
Publication Number
UMD18100-1110
Notices
RIGOL pro ducts are co vered by P.R.C. and f oreign p atents, issu ed and pendi ng. RIGOL reserves the right to modify or change parts of or all the specifications
and pricing policies at the company’ s s ole de cision .
Information in this publication replaces all previ ously released materials. Information in this publication is subject to change without notice. RIGOL shall not be liable for either incidental or consequential losses in
connection with the furnishing, use, or performance of this manual, as well as any information contained.
Any part of this document is f orbi dden to be copied , photoc opied, or rearranged
without prior written approval of RIGOL.
Product Certification
RIGOL guarantees that this product conforms to the national and industrial standards in China as well as the ISO9001:2008 standard and the ISO14001:2004 standard. Other international standard conformance certifications are in progress.
Contact Us
If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Websites: www.rigol.com
Page 4
RIGOL Content
DSA700 Options and Accessories
II
Content
Guaranty and Declaration ......................................................................... I
DSA700 Options and Accessories ............................................................. 1
Standard Accessories ............................................................................... 3
EMI Filter and Quasi-Peak Detector ......................................................... 4
Advanced Measurement Kit ...................................................................... 5
USB-GPIB Inte r f ac e Converter ............................................................... 11
Page 5
RIGOL
DSA700 Options and Accessories
1
DSA700 Options and Accessories
Options an d acces sori es p rovi ded by DSA700 series spectrum analyzer are as shown in the table below. If needed, please contact RIGOL or the local distributors. This manual only introduces the functions of some options. For the option with remark in the table below, refer to the dedicated manual.
Description
Order
Number
Model
spectrum analyzer, 100 kHz to 500 MHz (with preamplifier)
DSA705
spectrum analyzer, 100 kHz to 1 GHz (with preamplifier)
DSA710
Standard accessories
quick guide (hard copy) ­power cable -
Options
EMI filter & quasi-peak detector EMI-DSA800 advanced measurement kit AMK-DSA800 DSA PC software
[1]
Ultra Spectrum
signal seamless capture
SSC-DSA
Optional accessories
include: N-SMA cable, BNC-BNC cable, N-BNC adaptor, N-SMA adaptor, 75 Ω to 50 Ω adaptor, 900 MHz/1.8 GHz antenna (2pcs), 2.4 GHz antenna (2pcs)
[2]
DSA Utility Kit
include: N(F)-N(F) adaptor (1pcs), N(M)-N(M) adaptor (1pcs), N(M)-SMA(F) adaptor (2pcs), N(M)-BNC(F) adaptor (2pcs), SMA(F)-SMA(F) adaptor (1pcs), SMA(M)-SMA(M) adaptor (1pcs), BNC T type adaptor (1pcs), 50 Ω SMA load (1pcs), 50 Ω BNC impedance adaptor (1pcs)
[2]
RF Adaptor Kit
include: 50 Ω to 75 Ω adaptor (2pcs)
[2]
RF CATV Kit
include: 6dB attenuator (1pcs), 10dB attenuator (2pcs)
[2]
RF Attenuator Kit
30dB high power attenuator, max. power 100W
[2]
ATT03301H
N(M)-N(M) RF cable
[2]
CB-NM-NM-75-L
-12G
Page 6
RIGOL
DSA700 Options and Accessories
2
N(M)-SMA(M) RF cable
[2]
CB-NM-SMAM-7 5-L-12G
RF demo kit (transmitter)
[2]
TX1000
RF demo kit (receiver)
[2]
RX1000
near field probe
[2]
NFP-3
EMI pre-compliance test software
[3]
S1210 EMI
Pre-compliance
Software
rack mount kit
[2]
RM-DSA800
soft carrying bag BAG-G1 USB cable
CB-USBA-USBB­FF-150
USB to GPIB interface converter for instrument USB-GPIB
Remark:
[1] For more details of this option, refer to the help document of Ultra Spectrum (you can call the manual by clicking the icon
in the upper right corner of the software, or download the manual
from
www.rigol.com).
[2] For more details, refer to the corresponding manual (included in the option package in hard copy form, or download the manual from
www.rigol.com).
[3] For more details of this accessory, refer to the help document of S1210 EMI Pre-compliance Software (you can call the manual by clicking Help in the menu bar of the software, or download the manual from
www.rigol.com).
Page 7
RIGOL
DSA700 Options and Accessories
3
Standard Accessories
The following are the standard accessories.
Power Cord Quick Guide
Note: Images in this section are indicative only. The actual products you receive may differ.
Page 8
RIGOL
DSA700 Options and Accessories
4
EMI Filter and Quasi-Peak Detector
EMI-DSA800 option provi des Quasi-Peak detector and EMI filter (200 Hz, 9 kHz, 120 kHz, -6 dB bandwidth). Quasi-Peak detection is a weighted form of peak detection. For each data point, the detector detects the pea ks within t he specified time interval, weights the peaks detected using circuit with specified charge and discharge structures as well as the display time constant specified in the CISPR Publication 16 standards and display the result. By default, t he instrument uses Gauss filter and will switch to EMI filter automatically if Quasi-Peak detector is selected.
Press BW/Det at the front panel. Then, press Det Type to select Quasi-Peak detector. At this point, the instrument automatically changes the filter type to EMI and the Filter Type menu is g ra ye d ou t an d dis abl ed. EMI-DSA800 option is used in electromagnetic interference test.
Page 9
RIGOL
DSA700 Options and Accessories
5
Advanced Measurement Kit
AMK-DSA800 option provides various measurement functio ns, in cluding T-Power, ACP (Adjacent Channel Power), Chan Pwr (Channel Power), OBW (Occupied Bandwidth), EBW (Emissi on Bandwidt h), C/N Ratio, Harmo Dist (Harmonic Distortion) and TOI (Third Order Intermodulation). For advanced measurement functions, the measurement mode can be single or continuous and you can control the measurement including Restart, Pause and Resume.
Press Meas at the front panel and then press Meas Fctn to select a measurement function. The screen is divided into two windows with the upper window (the basic measurement window) displaying the sweep trace and the lower window displaying the measurement results.
1. T-power
The system enters zero span mode and calculates the power within the time domain. The types of powers available include Peak, Average and RMS.
Measurement Result Measurement Parameters
Measurement Control
Start Line Stop Line
Page 10
RIGOL
DSA700 Options and Accessories
6
2. ACP
Measure the powers of the main channel and adjacent channels as well as the power difference between the main channel an d each of the a djacent channels . When this function is enabled, the span and resolution bandwidth of the analyzer are adjusted to smaller values automatically.
3. Chan Pwr
Measure the power and power spectral density within the specified channel bandwidth. When this function is enabled, the span and resolution bandwidth are automatically adjusted to smaller values.
Main Channel Bandwidth
Adjacent Channel Bandwidth
Channel Spacing
Page 11
RIGOL
DSA700 Options and Accessories
7
4. OBW
Integrate the power within the whole span and calculate the bandwidth occupied by this power according to the specified power ratio. The OBW function also indicates the difference between the center frequency of the channel under measurement and the center frequency of the analyzer.
Integration Bandwidth Channel Power Span
Page 12
RIGOL
DSA700 Options and Accessories
8
5. EBW
Measure the bandwidth between two points on the si gnal which are X dB below the highest point within the span.
6. C/N Ratio
Measure the powers of the carrier and noise with the specified bandwidths as well as their power ratio.
Offset Frequency
Carrier Bandwidth
Noise Bandwidth
Page 13
RIGOL
DSA700 Options and Accessories
9
7. Harmo Dist
Measure the power of each order of harmonic and THD (total harmonic distortion) of the carrier. The highest order of harmonic available is 10 and the fundamental wave amplitude must be greater than -50 dBm, or else the measurement will be invalid.
Page 14
RIGOL
DSA700 Options and Accessories
10
8. TOI
Measure the parameters of the TOI production of two signals with the same amplitude a nd similar frequency. Those parameters include the frequencies and amplitudes of the Base Lower, Base Upper, 3rd Order Lower and 3rd Order Upper signal, as well as the Intercepts of both the Base Lower and Base Upper.
Page 15
RIGOL
DSA700 Options and Accessories
11
USB-GPIB Interface Converter
Through the RIGOL USB-GPIB interface converter, the spectrum analyzer can be connected to the GPIB bus controller of the PC, namely to expand a GPIB interface through which the spectrum analyzer can finish various tasks using the GPIB instructions more easily for the spectrum analyzer. The performance characteristics of the USB-GPIB interface converter are listed below.
Connect the USB interface and the GPIB interface of the USB-GPIB interface converter to the USB Host interface of the spectrum analyzer and the GPIB bus controller of the PC respectively.
Achieve GPIB control via the USB Host interface of the
spectrum analyzer.
Distribute a GPIB ad dress f or the spectrum analyzer via
the GPIB host device (PC).
USB powered instead of external power supply. Indicate the power status via a LED.
LED Power Indicator
Spectrum
Analyzer
PC
GPIB
USB
Loading...