RIGOL is a registered trademark of RIGOL Technol ogies , In c.
Publication Number
UMD01105-1110
Notices
RIGOL products are protected by patent law in and outside of P.R.C.
RIGOL Technologies, Inc. reserves the right to modify or change parts of or all
the specifications and pricing policies at company’s sole decision.
Information in this publication replaces all previously corresponding material.
RIGOL shall not be liable for losses caused by either incidental or consequential
in connection with the fu r nis hing , use or perfo rman ce of this manual as well as
any information contained.
Any part of this document is forbidden to copy or photocopy or rearrange without
prior written approval of RIGOL.
Product Certification
RIGOL guarantees this product conforms to the national and industrial standards in
China. International standard conformance certification is in progress, e.g. ISO.
Contact Us
If you have any problem or requirement when using our products or this manual,
please contact RIGOL.
E-mail: service@rigol.com
Websites: www.rigol.com
DSA1000&DSA1000A Options&Accessories
Page 4
RIGOL
2
Content
Guaranty and Declarat ion .................................................................................. 1
Power Cor d 1
USB Cable 1
Front Panel Cover 1
Quick Guide 1
CDROM 1 (User’s Guide, Programming Guide)
Optional Accessories
Desk Mount Instrument Arm ARM
DSA Accessories Package DSA Utility Kit*
Front Panel Cover
Soft Carrying Bag DSA1000-SCBA
Rack Mount Kit DSA1000-RMSA
*Note: please refer to the corresponding documents for more information.
DSA1030-TG3 (For DSA1030 only)
USB-GPIB
RIGOL
DSA1000&DSA1000A Options&Accessories
Page 6
RIGOL
4
DSA1000A Series Options&Accessories
Name Description
Options
3 GHz Tracking Generator DSA1030-TG3
PC software for PC Ultra Spectrum*
USB to GPIB Interface Converter for
Instrument
RF Demo Kit (Transmitter) TX1000*
Standard Accessories
Power Cor d 1
USB Cable 1
Front Panel Cover 1
Quick Guide 1
CDROM 1 (User’s Guide, Programming Guide)
Optional Accessories
Desk Mount Instrument Arm ARM
RF Demo Kit TX1000
DSA Accessories Package DSA Utility Kit*
Front Panel Cover DSA1000-FPCS
Soft Carrying Bag DSA1000-SCBA
Rack Mount Kit DSA1000-RMSA
*Note: please refer to the corresponding documents for more information.
USB-GPIB
DSA1000&DSA1000A Options&Accessories
Page 7
RIGOL
5
Preamplifier
Turning on the preamplifier reduces the displayed average noise level in order to
distinguish small signals from the noise when working with small signals. For the
instruments supported option DSA1030-PA, pressing the front panel key AMPT, a
corresponding menu will appear on the right of the screen. Then, press RFPreamp
to turn on or off the pre amplifier . An ico n
when the preamplifier is on. The preamplifier will be disabled automatically when the
input attenuation is set higher than 30 dB.
The measurement results when the preamplifier is off and on are shown below,
respectively. As can be see n, small input signals can be displayed by the analyzer
when the preamplifier is on.
will be displayed on the left of the screen
PA Off
PA On
DSA1000&DSA1000A Options&Accessories
Page 8
RIGOL
6
Measured Result Parameters
Measure Control
Start Line Stop Line
Advanced Measurement Functions
Option DSA1000-AMK prov ides plenty of advanced measurement functions including
T-Power (Time domain Power), ACP (Adjacent Channel Power), Chan Pwr (Channel
Power), OBW (Occupied Bandwidth), EBW (Emission Bandwidth), C/N Ratio, Harmo
Dist (Harmonic Distortion), TOI (Third Order Intermodulation) and Pass/Fail. The
measure mode c an be Single or Continuous and you can control the measurement
status: Restart, Pause or Resume.
Pressing the front panel key Meas, the corresponding menu will appear on the right
of the screen. Press Meas Fctn and cho ose a measurement function. T he screen will
be divided into two windows. The upper one is for basic m easure, displaying sweep
trace, and the lower one shows the measurement results.
1. T-Power (Time domain Power)
Enables the Zero Span Mode and calculates the power within time domain. The
measurabl e power types are Peak, Ave rage and RMS.
DSA1000&DSA1000A Options&Accessories
Page 9
7
2. ACP (Adjacent Channel Power)
Main CH BW
Adj CH BW
CH Spacing
Measures the power of the main channel and the adjacent channels and
calculates the power difference between the main and each of the adjacent
channels. When enabled, both the span and resolution ban dwidth of the analy zer
are adjusted to be smaller automatically.
RIGOL
3. Chan Pwr (Channel Power)
Measures the power and the power density within a specified chan nel bandwidth.
The span and bandwidth are automatically set to smaller values in this
measurement type.
Integ BW CH Pwr Span
DSA1000&DSA1000A Options&Accessories
Page 10
RIGOL
8
4. OBW (Occupied Bandwidth)
Calculates the power within wh ole bandwidth by integr al operati on and works out
the occupied bandwidth by this value based on the specified power ratio. The
center frequency difference between the measured channel and the analyzer wil l
also be given in the measurement results.
5. EBW (Emission Bandwidth)
Measures the bandwidth of the two points at both sides of the max signal when
the amplitude of this max signal falls off X dB within the span range.
DSA1000&DSA1000A Options&Accessories
Page 11
9
6. C/N Ratio
Noise BW
Offset Freq
Carrier BW
Measures the power of bo t h the c arrie r and t he noise within specified bandwidth
and calculates their ratio.
RIGOL
7. Harmo D ist (Harmonic Disto rtion)
Measures each order harmonic power and THD (Total Harmo nic Distortion) of
carrier. The available range is up to 10 orders. And the fundamental wave
amplitude of the carrier must be higher than -50 dBm or else the measurement
will be invalid.
DSA1000&DSA1000A Options&Accessories
Page 12
RIGOL
10
8. TOI (Third Order Intermodulation)
Measures the parameters of the TOI production generated by two signals which
have the same amplitude and similar frequency. The measured results include the
frequency and amplitude of the Base Lower, Base Upper, 3rd Order Lower an d 3rd
Order Upper signals, as well as the Intercept of both the 3rd Order Lowe r and 3rd
Order Upper sign a l s.
9. Pass/Fail
Compares the measured curve with the pre-edited, if the r elated rules are met,
the result will be “Pass”, or else is “Fail”.
DSA1000&DSA1000A Options&Accessories
Page 13
RIGOL
11
3 GHz Tracking Generator
When the Tracking Generator (DSA1030-TG3 Option) is on, a signal with the same
frequency with the current sweep signal will be outputted from the GEN OUTPUT 50 Ω terminal on the front panel. The powe r of the sig nal could be set throu gh the menu.
And two working modes, P ower Sweep Output an d Fix ed P ower Out put, a re av ailable.
The characteristic of the DUT (Device Under Test) can be acquired by measuring the
response of the DUT stimulated by the Tracking Generator. For example, the
frequency response of a filter can be measured by using the Tracking Generator.
Connect the filter under measure to the RF INPUT 50Ωand GEN OUTPUT 50Ω
terminal of the analyzer.
Filter
Measurements Example
The frequency response of a 300 MHz low-pass filter is shown below.
DSA1000&DSA1000A Options&Accessories
Page 14
RIGOL
12
Item
Condition
Value
Tracking Generator Specifications
Frequency Range 9 kHz to 3 GHz
Output Power -20 dBm to 0 dBm, in 1 dB
steps
Output Flatness 10 MHz to 3 GHz,
Reference to 50 MHz
±3 dB
DSA1000&DSA1000A Options&Accessories
Page 15
RIGOL
13
USB
USB-GPIB Interface Converter
By using RIGOL USB-GPIB interface converter, the spectrum analyzer could be
connected to a GPIB Bus Controller on PC. That is, the analyzer has been expanded
GPIB interface and coul d finish all sorts of work more easil y through GPIB instructions.
And the main performance characters are shown below.
Enable GPIB control of the analyzer through the USB
Host port.
GPIB primary addre ss of the analyzer can be assigned
through the host instrument (PC).
Powered by USB Host, do no t need external power
supply.
LED indicator provides the power status.
Connect the USB interface of the converter to the USB Host interface of the analyzer,
and connect the GPIB interface to the GPIB Bus Controller on PC.
LED Indicator
PC
GPIB
Analyzer
DSA1000&DSA1000A Options&Accessories
Page 16
RIGOL
14
Front Panel Cover
The cover is provided to avoid damage to the front panel of the analyzer during
transportation.
Before putting your analyzer into action, remove the front panel cover by releasing
latches at both sides, and sliding in the direction of the arrows as shown in the figure
below.
DSA1000&DSA1000A Options&Accessories
Page 17
RIGOL
15
Desk Mount Instrument Arm
Using an arm, the analy zer could be mounted on the workdesk t o sa ve y ou r op erat ion
space. The height and angle of the instrument could be adjusted freely to acquire a
supreme comfort and efficiency making measurement and observation conveniently.
To use the arm, please order the related option.
The effects figures of an analyzer installed to an arm are given below.
DSA1000&DSA1000A Options&Accessories
Page 18
RIGOL
16
Rack Mount Kit
The analyzer could be installed in 19-inch standard machine cabinet, shown below.
1. Kit Parts List
No. Name Qty. Part Number Description
1-1 Front Panel 1 RM-DSA-1-01
1-2 Support Board 1 RM-DSA-1-02
1-3 Left Plate 1 RM-DSA-1-03
1-4 Right Plate 1 RM-DSA-1-04
1-5 Fixed Figure 2 RM-DSA-1-05
1-6 Rear Support B a r 1 RM-DSA-1-06
2-1 M4 Screw 20 RM-SCREW-01 M4*6 Phil-Slot Pan Head
Machine Screw Nail
2-2 M6 Screw 4 RM-SCREW-02 M6*16 Phil-Slot Pan Head
2-4 M4 Screw 4 RM-SCREW-04 M4*8 Cross Recessed Pan
Head Screw
DSA1000&DSA1000A Options&Accessories
Page 19
RIGOL
17
2-1 2-2 2-3 2-4
2. Installation Tool
PH2 Phillips Screwdriver (recommended)
DSA1000&DSA1000A Options&Accessories
Page 20
RIGOL
18
3. Space Requir ements for Installation
The following requirements must be fulfilled by the machine cabinet in which the
instrument is mounted.
Dimension of the machine cabinet must be standard 19-inch.
At least 6U (266.7mm) space should be provided by the machine cabinet.
The depth inside the machine cabinet should not be less than 300 mm.
The dimension of the instrument after being installed is shown below.
DSA1000&DSA1000A Options&Accessories
Page 21
RIGOL
19
4. Installation Procedures
A PH2 Phillips Screwdriver is recommended. Note that the instrument will be
damaged or installed in ra ck incorrectly if the i nstallation is not p roper. Thus, only
authorized operators can execute the installation operation.
1) Install the right and left palate: aim the detents of right and left plate at the
opening s on support board and insert respectively, then f ix them using six M4
screws.
2) Place the instrument: Remove the battery* by pressing the button on top of it,
and then place the instrument into the confined position on the Support Board.
*Note: the battery is only supplied in China.
DSA1000&DSA1000A Options&Accessories
Page 22
RIGOL
20
3) Fix the instrument: Fix a “Rear Support Bar” and two “Fixed Figure” on the
instrument using four M4*8 Screws. Locate the inst rument on p roper location and
then f ixed the “Rear Support Bar” and “Fixed Figur e” on the left/right board and
the Support Board using eight M4*6 Screw.
4) Mount Front Panel: Let the screw holes fitting well together, and aiming the
instrument front panel at t he openin g of the F ront Panel of the machine rac k and
fix them with six M4 screws.
DSA1000&DSA1000A Options&Accessories
Page 23
RIGOL
21
5) Load into machine cabinet: mount the rack with instrument-fixed into a standard
19-inch machine cabinet respectively using four M6 screws and square nuts.
6) Notice: The rack holds a height of 6U, and the holes those in complian ce with t he
arrow direction are the mounting holes for rack.
DSA1000&DSA1000A Options&Accessories
Page 24
RIGOL
22
RIGOL
Soft Carrying Bag
The bag is designed by
model measurement instruments. It has
reasonable structure as adopting some
improvements according to the instrument
and practical application. It is in conformity
with human engineering and could help
you to carry instrument and its accessories
easily with comforts and conveniences .
for utility
Main features
Could be held by hand, one-shoulder or shoulders. In addition, one of the belts
could be adjusted as neck strap thr ough the v ertical st rap loop , while another o ne
as waist strap. In this condition, the operator could execute the measurement
work, and it could reduce the load on shoulders.
Soft bag body. And the shoulder straps and belts are equipped by sponge to
increase the contact area of the case on human body. It is in conformity with
human engineering and provides greatly comforts.
A strap collection box at the bottom of the case is designed to collect the straps
while using belts and ensure the straps do not prevent user’s work.
Many pockets inside for organizing the instrument accessories; have strong
accommodating function.
The built-in water-proof bag can accommodate the case body entirely to avoid
damage from w ater or rain and ensure its normal use and service life; while not in
use, fold it up and place it in the hidden pocket outside of the case body and
without preventing normal applications.
DSA1000&DSA1000A Options&Accessories
Page 25
RIGOL
23
Held by shoulders Held by Neck&Waist Carried by Hand
DSA1000&DSA1000A Options&Accessories
Page 26
RIGOL
24
Other Accessories
Accessories along with the instrument are shown below. Note that the pictures here
are for your re ference only. Some differences may exist.
Power Cord USB Cable
Quick Guide CDROM*
Front Panel Cover
*Note: The CD contains