RIGHT ANGLE NEWHEIGHTS Series 4 XT, 53209 Assembly & Operation Instructions

NewHeights™ Series 4 XT Elegante 3-Leg Workstation
Assembly/Operation Instructions
K&A Manufacturing 6703 Zinser Street Schofield, WI 54476 Phone: 800.298.4351 Fax: 866.882.9475 www.raproducts.com Version Dated 8/4/16
Failure to comply with or observe all assembly, safety, and operation instructions and warnings regarding the use of this product may result in serious property damage or bodily injury.
Make sure no obstacles are in the desk's path and all cords are of appropriate length for the desk. Always maintain a 1" clearance around the table to prevent pinching.
Never assemble (or disassemble) the table or components with the table plugged into a power outlet. This product is for use on a nominal 120-volt circuit and has a grounding plug. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product.
Duty Cycle: 2 minutes ON/18 minutes OFF Workstation can continuously operate for a maximum duration of two minutes. After two minutes of non-stop operation, the workstation will automatically stop and require eighteen minutes of cool down.
Page1 OF 9Instruction # 53210 Hardware Pack # 53209
K&A Manufacturing
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
Your workstation will have either (2) left legs (Leg A) and (1) right leg (Leg B) or (2) right legs (Leg B) and (1) left leg (Leg A). The drawing below shows how to distinguish the left leg A from the right leg B.
Leg A
Leg B
Left Return
Leg A
Leg A
Note: Motor box faces inside of table
Note: Motor box faces inside of table
4
Leg B
Leg B
Right Return
4
Front
Leg A Left Leg
Instruction # 53210
Front
Leg B Right Leg
Page 2 OF 9
K&A Manufacturing
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
Tools Required for Assembly:
Power Driver W/Adjustable Torque #2 Phillips Head Driver Bit #2 Square Head Driver Bit 3/16" Hex Head Driver Bit or Allen Wrench Level
51708
53174
3
8
53638
52604
6
12
53176
50072
7
10
Instruction # 53210
Hardware Pack # 53209
Hardware is Drawn Actual Size
Page 3 OF 9
K&A Manufacturing
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
All Screws
These Steps
3
Steps 1 & 2
Step 1: With the help of an assistant, lay the work-
surface(s) 1 on a protected surface with the pilot holes facing up. If your worksurface has a seam, lay the joiner plate 2 centered on the seam and about 3" from the front. Attach it with (8) wood screws 3 . No pilot holes are provided. Do not over-tighten the screws. Use a low torque setting on the power driver.
Step 2: Place all (3) leg assemblies 4 on the worksurface aligning the holes in the worksurface supports with the pilot holes in the worksurface
4
1 . See page 2 to determine the locations of Leg A and Leg B. The motor boxes must face the inside of the workstation. Do not allow the leg assemblies to stand without support. They can tip over and the
gear housing could crack. Be careful to not pinch the wires between the motor boxes and the worksurface 1 . The
1
grommets on the motor wires should be in the square notches on the back of the motor boxes.
3
See Detail A. Attach the leg assemblies to the worksurface with (6) wood screws 3 in each. Leave the screws loose by about 1/8". You need to
2
adjust the legs when installing the wire management channel.
ITEM # PART # DESCRIPTION QTY.
1 Varies Worksurface Varies 2 800352 3x5 Worksurface Joiner Plate 1
3 51708 M5 x 18mm (7/8") Sq/Ph/Wshr Head Wood Screw 49 4 Varies NewHeights Series 4 XT Leg Assembly 3 5 Varies NewHeights Series 4 XT Wire Management Channel 2 6 53638 5/16-18 x 3/8 Button Head Socket Screw 6
7 53176 .25x.696x.58 Flat Washer 4 8 53174 1/4-20x1/2 Phillips Pan Head Machine Screw 4
9 53225 TouchDown Hand Switch 1
10 50072 8 x 3/4 Pan Head Recex Drive Screw 4 11 50286 NewHeights Control Box 1
12 52604 3/16" Cable Clamp 4 13 PSSM-4-2 Power Strip 4 Recps 2 USB Chargers 10 Ft Cord 1
Instruction # 53210
Back of
Motor Box
Detail A
Page 4 OF 9
6703 Zinser Street Schofield, WI 54476
K&A Manufacturing
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
Step 3: Your workstation may have two different sizes of wire management channel 5 . Determine the correct locations of the channels according to the length and width of the worksurface(s). Slide apart the channel until the holes near the ends of it align with the holes in the motor boxes on the desk side of the workstation. Place the flat side of the channel against the motor boxes. Insert (4) socket screws 6 through the holes near the ends of the channel and thread them into the weld nuts inside the motor boxes. See Detail B. Fully tighten. Fully tighten the wood screws 3 holding the desk side leg assemblies to the worksurface 1 . Attach the channel to the worksurface with (5-10) wood screws 3 through the front flange of the channel. Fully tighten. Keep the wood screws at the end of the slots.
5
6
Detail B
3
B
Instruction # 53210
Step 3
Page 5 OF 9
K&A Manufacturing
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
Step 4: Attach the other wire management channel 5 to the third leg 4 on the return side of the table. See Detail B on Page 5. Fully tighten all of the screws. Fully tighten the(6) wood screws 3 attaching the third leg to the worksurface 1 . Attach the wire management channel to the worksurface with (4-10) wood screws 3 .
Step 5: Place (2) black flat washers 7 on (2) black machine screws 8 . Insert these through the slots in one of the outer wire management sections and thread them into the cage nuts pre-installed near the end of the inner wire management section. See Detail C. Use any (2) cage nuts that are accessible. Fully tighten. Repeat Step 5 with the remaining wire management channel.
Cage Nuts Pre-
installed in Inner
Wire Management
Channel
7
8
Detail C
Instruction # 53210
C
Steps 4 & 5
Page 6 OF 9
Step 6: Align the holes in the control box 11 with the pilot holes in the worksurface 1 . Attach it with (2)
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
K&A Manufacturing
recex screws 10 . Align the holes in the switch 9 with the pilot holes in the worksurface. Attach it with (2) recex drive screws 10 . The switch and control box can be installed anywhere on the worksurface, wire
lengths permitting. Capture the switch wire in the cable clamp 12 and attach it in the location shown with (1) wood screw 3 . No pilot hole is provided.
Step 7: Attach the power strip 13 at the suggested location shown. It can be installed anywhere. Attach it with the screws that came with the power strip.
13
Steps 6 & 7
Instruction # 53210
10
11
3
10
9
12
Page 7 OF 9
K&A Manufacturing
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
HS
M1 M2 M3
Hand
Switch
Left
Hand
Center
Column
Column
Column
11
Right Hand
Step 8: Run the wires as shown in the wire runs diagram below. Run the wires in the wire management channels
5. Plug the wire from the switch into the receptacle labeled HS on the control box 11 . Plug the motor wires into the cables and plug the other ends of the cables into into the receptacles labeled M1, M2, and M3 as shown in the wiring diagram at left. Place the excess cable inside the channels.
Step 9: If your workstation will get an optional cross support(s), plug the unit into a standard 110 volt receptacle. Push the down arrow until the worksurface reaches its lowest point and clicks. Push the up arrow and raise the legs about 12". Install the cross support(s) using the supplemental instructions that came with the cross support package(s). Return the legs to the lowest position and unplug the power.
Step 10: With the help of an assistant, set the work­station upright in its final location. Level the unit if required by turning the leveling glides clockwise (from the top) on the low corners of the workstation. If your workstation has casters, level it by turning the bolts at the top of the casters.
Leveling Glide
Switch Wire
Motor Wire
Power Cord Power Strip
Power Cord Control Box
Instruction # 53210
Motor Wire
Motor Wire
Page 8 OF 9
K&A Manufacturing
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
Operation and Reset Procedure
Plug the power cord into a standard 110v receptacle. A power surge protector is recommended. Press the down arrow button until the worksurface reaches its lowest position and clicks. The NewHeights™ workstation is ready for use. If you unplug or lose power and the unit does not operate, follow the reset procedure below.
Reset Procedure: Unplug the power for 30 seconds and plug back in. Hold the down arrow button until the unit stops at the bottom. Release the button; then hold the down arrow button until the unit clicks twice.
Troubleshooting: If you are having any problems with the table operation, contact RightAngle™ service at 800-298-4351 or orders@raproducts.com.
Warranty Information: NewHeights™ products are warranted to be free of defects due to manufacturing or materials as follows: Three years on the gear and/or motor(s) including the control box and switch. Five years on the support brackets, aluminum columns and feet. We will replace any defective part after inspection by an authorized agent. Costs incurred due to product replacement such as installation labor or transportation are not covered by this warranty. When corresponding with RightAngle™ products, record and provide the model and serial numbers located on the control box.
Instruction # 53210
Page 9 OF 9
Loading...