RIDGID R860424, R8604241 Operator's Manual

OPERATOR’S MANUAL
MANUEL D’UTILISATION
MANUAL DEL OPERADOR
18 V HYBRID FORCED AIR PROPANE HEATER
APPAREIL DE CHAUFFAGE HYBRIDE AU PROPANE
ET À AIR FORCÉ DE 18 V
CALENTADOR A GAS PROPANO DE AIRE FORZADO
HÍBRIDO DE 18 V
R860424
R8604241
To register your RIDGID
product, please visit:
http://register.RIDGID.com
Pour enregistrer votre
produit de RIDGID,
s’il vous plaît la visite :
http://register.RIDGID.com
Para registrar su producto
de RIDGID, por favor visita:
http://register.RIDGID.com
INCLUDES: Forced Air Propane Heater,
Regulator and Hose Assembly, Operator’s Manual
TABLE OF CONTENTS
****************
Important Safety Instructions ..........2-4
Propane Heater Safety Warnings .......4
Symbols ............................................. 5
Electrical ............................................6
Features .............................................7
Tools Needed .....................................7
Assembly ........................................7-8
Operation ........................................8-9
Maintenance ....................................10
 Parts Ordering and
Service ................................Back page
WARNING:
To reduce the risk of injury, the user must read and understand the operator’s manual before using this product.
INCLUT : Appareil de chauffage au propane et à air forcé, assemblage de régulateur et de tuyau, manuel del utilisation
TABLE DES MATIÈRES
****************
Instructions importantes
concernant la sécurité ....................2-4
Avertissements de sécurité relatifs
appareil de chauffage au propane ..... 4
Symboles ........................................... 5
Caractéristiques électriques .............. 6
Caractéristiques ................................. 7
 Outils nécessaires .............................. 7
Assemblage ....................................7-8
Utilisation ........................................8-9
Entretien ........................................... 10
Illustrations .................................. 11-12
Commande de
pièces et dépannage ........Page arrière
AVERTISSEMENT :
Pour réduire les risques de blessures, l’utilisateur doit lire et veiller à bien comprendre le manuel d’utilisation avant d’utiliser ce produit.
INCLUYE: Calentador a gas propano de aire forzado, Ensamblaje de regulador y manguera, manual del operador
ÍNDICE DE CONTENIDO
****************
Instrucciones de seguridad
importantes.................................... 2-4
Advertencias de seguridad
calentador a gas propano .................4
Símbolos ............................................5
Aspectos eléctricos ...........................6
 Características ................................... 7
 Herramientas necesarias ...................7
Armado .......................................... 7-8
Funcionamiento ............................. 8-9
Mantenimiento .................................10
Ilustraciones .............................. 11-12
Pedidos de
piezas y servicio ...........Pág. posterior
ADVERTENCIA:
Para reducir el riesgo de lesiones, el usuario debe leer y comprender el manual del operador antes de usar este producto.
SAVE THIS MANUAL FOR
FUTURE REFERENCE
CONSERVER CE MANUEL
POUR FUTURE RÉFÉRENCE
GUARDE ESTE MANUAL
PARA FUTURAS CONSULTAS
IMPORTANT SAFETY INSTRUCTIONS
DANGER:
Carbon Monoxide. Using a propane heater
indoors CAN KILL YOU IN MINUTES. Propane heater exhaust contains high levels of
carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the propane heater exhaust, you are breathing CO. But even if you cannot smell the exhaust, you could be breathing CO.
 Never use a propane heater inside homes,
garages, crawlspaces, recreational vehicles, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air.
 ONLY use a propane heater outdoors and far
away from open windows, doors, and vents. These openings can pull in propane heater exhaust.
Propane cylinder must be located outdoors during operation except during construction or renovation of buildings not occupied by the public.
Even when you use a propane heater correctly, CO may leak into the home. ALWAYS use a battery­powered or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, weak, or experience a headache after the propane heater has been run­ning, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning. Do not sleep while propane heater is operating.
DANGER:
If you smell propane gas, shut off propane to the heater at the propane cylinder. If odor continues, keep away from the heater and immediately call your propane gas supplier or your fire department.
WARNING:
FIRE, BURN, INHALATION, AND EXPLO­SION HAZARD. KEEP SOLID COMBUS­TIBLES, SUCH AS BUILDING MATERI­ALS, PAPER, OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUC­TIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTI­BLES, OR PRODUCTS SUCH AS GASO­LINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
WARNING:
FAILURE TO COMPLY WITH THE PRE­CAUTIONS AND INSTRUCTIONS PRO­VIDED WITH THIS HEATER CAN RESULT IN DEATH, SERIOUS BODILY INJURY, AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MON­OXIDE POISONING, AND/OR ELECTRI­CAL SHOCK.
ONLY PERSONS WHO CAN UNDER­STAND AND FOLLOW THE INSTRUC­TIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUC­TIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE.
WARNING:
Adequate ventilation must be provided. A minimum 2 ft. sq. (0.19 m2) ventilation opening near floor and 2 ft. sq. (0.19 m2) ventilation opening near ceiling must be in place during use of this heater. Do not sleep while heater is operating.
WARNING:
Read and save these instructions. Failure to
follow all instructions listed below, may result in electric shock, fire and/or serious personal injury.
SAVE THESE INSTRUCTIONS
When using propane:
This propane product must be installed in accordance
with the latest local codes. In the absence of local codes, use the:
• United States: — National Fuel Gas Code, ANSI Z223.1/NFPA 54 — LP Gas Code, NFPA 58
• Canada: — Natural Gas and Propane Installation Code, CSA
B149.1
— Propane Storage and Handling Code, CSA B149.2.
2 - English
IMPORTANT SAFETY INSTRUCTIONS
Always turn off gas at the propane cylinder (liquid propane
also called liquid petroleum gas) when the product is not in use. Disconnect the cylinder before storage.
Before storing, allow the product to cool for 30 minutes
and remove propane cylinder from the unit. Do not store a propane cylinder attached to or near the product. If not followed exactly, a fire causing death or serious injury may occur.
Inspect the hose for damage before each use. If it is
evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the product being put into operation. The replacement hose assembly shall be that specified by the manufacturer. Use only replacement hose part no. TYQ-5B1-QG005.
This heater must be located on stable and level surface
and located away from combustible surfaces by no less than 24 inches from rear and sides of heater and 72 inches from above and front outlet of heater.
Never fill the propane cylinder beyond 80 percent full. An
overfilled or improperly stored cylinder is a hazard due to possible gas release from the safety release valve. If not followed exactly, a fire causing death or serious injury may occur.
Only use a propane cylinder that includes a collar to
protect the cylinder valve.
If a leak is detected at any time, get away from the
propane cylinder and call the fire department.
Do not use the product until leak-tested. Propane cylinders must be stored outdoors out of reach
of children and must not be stored in a building, garage, or any other closed in area.
WORK AREA
Keep your work area clean and well lit. Cluttered
benches and dark areas invite accidents.
Do not operate propane heaters in explosive atmo-
spheres, such as in the presence of flammable liquids, gases, or dust. Propane heaters create sparks which
may ignite the dust or fumes.
ELECTRICAL SAFETY
A battery operated product with integral batteries or
a separate battery pack must be recharged only with the specified charger for the battery. A charger that
may be suitable for one type of battery may create a risk of fire when used with another battery.
Use battery operated product only with specifically
designated battery pack. Use of any other batteries
may create a risk of fire.
Use this product only with batteries and chargers listed
in tool/appliance/battery pack/charger correlation supplement 988000-302.
Protect the power cord from being walked on or
pinched particularly at plugs, convenience recep­tacles, and the point where they exit from the product.
Unplug this product during lightning storms or when
when not in use.
PERSONAL SAFETY
Dress properly. Do not wear loose clothing or jewelry.
Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long
hair can be caught in moving parts.
Avoid accidental starting. Be sure switch is in the
locked or off position before inserting battery pack or extension cord. Carrying the product with your finger on
the switch or inserting the battery pack or extension cord into the product with the switch on invites accidents.
Do not overreach. Keep proper footing and balance
at all times. Proper footing and balance enable better
control of the product in unexpected situations.
Do not wear loose clothing or jewelry. Contain long
hair. Loose clothes, jewelry, or long hair can be drawn
into air vents.
Do not use on a ladder or unstable support. Stable
footing on a solid surface enables better control of the product in unexpected situations.
PROPANE HEATER USE AND CARE
Do not use the product if switch does not turn it on or
off. A product that cannot be controlled with the switch
is dangerous and must be repaired.
Disconnect battery pack or extension cord from
the product or place the switch in the locked or off position before making any adjustments, changing accessories, or storing the product. Such preventive
safety measures reduce the risk of starting the product accidentally.
When battery pack is not in use, keep it away from
other metal objects like: paper clips, coins, keys, nails, screws, or other small metal objects that can make a connection from one terminal to another. Shorting
the battery terminals together may cause sparks, burns, or a fire.
Keep the product and its handle dry, clean and free
from oil and grease. Always use a clean cloth when
cleaning. Never use brake fluids, gasoline, petroleum­based products, or any strong solvents to clean your product. Following this rule will reduce the risk of loss of control and deterioration of the enclosure plastic.
To reduce the risk of electric shock, do not use this
product near water, especially when it is powered by the power cord.
Clean only with dry cloth. Do not operate near any other heat sources such as
radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
SERVICE
Propane heater service must be performed only by
qualified repair personnel. Service or maintenance
performed by unqualified personnel may result in a risk of injury.
3 - English
IMPORTANT SAFETY INSTRUCTIONS
When servicing a propane heater, use only identical
replacement parts. Follow instructions in the Main-
tenance section of this manual. Use of unauthorized
parts or failure to follow Maintenance Instructions may create a risk of shock or injury.
PORTABLE PROPANE HEATER SAFETY WARNINGS
Know your product. Read operator’s manual carefully.
Learn its applications and limitations, as well as the specific potential hazards related to this product. Fol-
lowing this rule will reduce the risk of electric shock, fire, or serious injury.
Battery tools do not have to be plugged into an elec-
trical outlet; therefore, they are always in operating condition. Be aware of possible hazards when not using
your battery tool or when changing accessories. Follow­ing this rule will reduce the risk of electric shock, fire, or serious personal injury.
Do not place propane heaters or their batteries near
fire or heat. This will reduce the risk of explosion and
possibly injury.
Do not crush, drop or damage battery pack. Do not
use a battery pack or charger that has been dropped or received a sharp blow. A damaged battery is subject
to explosion. Properly dispose of a dropped or damaged battery immediately.
Batteries can explode in the presence of a source
of ignition, such as a pilot light. To reduce the risk of
serious personal injury, never use any cordless product in the presence of open flame. An exploded battery can propel debris and chemicals. If exposed, flush with water immediately.
Do not charge battery tool in a damp or wet location.
Do not use, store, or charge battery packs or products in locations where the temperature is less than 50°F or more than 100°F. Do not store outside or in vehicles.
Under extreme usage or temperature conditions, bat-
tery leakage may occur. If liquid comes in contact with your skin, wash immediately with soap and water, then neutralize with lemon juice or vinegar. If liquid gets into your eyes, flush them with clean water for at least 10 minutes, then seek immediate medical attention.
Following this rule will reduce the risk of serious personal injury.
Do not incinerate the battery even if it is severely
damaged. The batteries can explode in a fire.
To reduce the risk of fire or electric shock, do not use
this product with any solid-state speed control device.
Not for use in kitchens, bathrooms, or other places
where water may be present.
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
Make sure your extension cord is in good condi-
tion. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. A wire gauge size (A.W.G.) of at least 16 is
recommended for an extension cord 100 feet or less in length. A cord exceeding 100 feet is not recom­mended. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord. An
undersized cord will cause a drop in line voltage resulting in loss of power and overheating.
To reduce the risk of personal injury and electric
shock, the product should not be played with or placed where small children can reach it.
To reduce the risk of electric shock, do not expose to
water or rain.
Never attempt to power the device with a battery pack
and extension cord at the same time.
The minimum surrounding air temperature rating for
this heater is OºF (-17ºC). Not for use with ductwork. When using propane:
Use the forced air heater only with propane and the
regulator/valve assembly supplied. The hose assembly shall be protected from traffic, build-
ing materials, and contact with hot surfaces both during
use and while in storage. Check for leaks prior to forced air heater operation. Do
this even if this forced air heater was assembled at the
store. Do not operate the forced air heater if there is a gas leak
present.
Never use a flame to check for gas leaks. Propane gas is not natural gas. Do not try to convert this
forced air heater to natural gas as it will void the warranty
and is extremely dangerous. Place dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap on
the cylinder valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result in leakage
of propane. Do not store propane cylinders, gasoline, or other
flammable liquids in the vicinity of the forced air heater.
Shut down the forced air heater and allow to cool for five
minutes before changing the propane cylinder.
Do not smoke when attaching or removing the propane
cylinder. Save these instructions. Refer to them frequently and
use them to instruct others who may use this tool. If you
loan someone this tool, loan them these instructions also.
4 - English
SYMBOLS
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER:
WARNING:
CAUTION:
NOTICE:
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the product better and safer.
Indicates a hazardous situation, which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation, that, if not avoided, may result in minor or moderate injury.
(Without Safety Alert Symbol) Indicates information considered important, but not related to a potential injury (e.g. messages relating to property damage).
SYMBOL NAME DESIGNATION/EXPLANATION
Safety Alert Indicates a potential personal injury hazard.
Read Operator’s Manual
Wet Conditions Alert Do not expose to rain or use in damp locations.
To reduce the risk of injury, user must read and understand operator’s manual before using this product.
Running a propane heater gives off carbon monoxide, an odor-
Toxic Fumes
Hot Surface and Exhaust Gases
Recycle Symbol
V Volts Voltage A Amperes Current
Hz Hertz Frequency (cycles per second)
W Watt Power
min Minutes Time
Direct Current Type or a characteristic of current Alternating Current Type of current
Class II Tool Double-insulated construction
less, colorless, poison gas. Breathing carbon monoxide can cause nausea, fainting, or death.
To reduce the risk of injury or damage, avoid contact with any hot surface and do not place any body parts in the path of hot exhaust gases.
This product uses lithium-ion (Li-ion) batteries. Local, state or federal laws may prohibit disposal of batteries in ordinary trash. Consult your local waste authority for information regarding available recycling and/or disposal options.
5 - English
ELECTRICAL
DOUBLE INSULATION
Double insulation is a concept in safety in electric products, which eliminates the need for the usual three-wire grounded power cord. All exposed metal parts are isolated from the internal metal motor components with protecting insulation. Double insulated products do not need to be grounded.
WARNING:
The double insulated system is intended to protect the user from shock resulting from a break in the product’s internal wiring. Observe all normal safety precautions to avoid electrical shock.
NOTE: Servicing of a product with double insulation requires extreme care and knowledge of the system and should be performed only by a qualified service technician. For service, we suggest you return the product to your nearest authorized service center for repair. Always use original factory replace­ment parts when servicing.
ELECTRICAL CONNECTION
This product should be connected to a power supply that is 120 volts, AC only (normal household current), 60 Hz.
Do not operate this product on direct current (DC) through the power cord. A substantial voltage drop will cause a loss of power and the motor will overheat. If the product does not operate when plugged into an outlet, double-check the power supply.
EXTENSION CORDS
When using a product at a considerable distance from a power source, be sure to use an extension cord that has the capacity to handle the current the product will draw. An undersized cord will cause a drop in line voltage, resulting in overheating and loss of power. Use the chart to determine the minimum wire size required in an extension cord. Only round jacketed cords listed by Underwriter’s Laboratories (UL) should be used.
When using this product outdoors, use an extension cord that is designed for outside use. This type of cord is desig­nated with “WA” or “W” on the cord’s jacket.
Before using any extension cord, inspect it for loose or exposed wires and cut or worn insulation.
**Ampere rating (on product data plate)
0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
Cord Length Wire Size (A.W.G.)
25' 16 16 16 16 14 14 50' 16 16 16 14 14 12 100' 16 16 14 12 10 —
**Used on 12 gauge - 20 amp circuit
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools, or other obstructions while you are working with this product. Failure to do so can result in serious personal injury.
WARNING:
Check extension cords before each use. If dam­aged replace immediately. Never use a product with a damaged cord since touching the damaged area could cause electrical shock resulting in seri­ous injury.
WARNING:
To reduce the risk of electric shock, use only with an extension cord intended for outdoor use, such as an extension cord of cord type SW-A, SOW-A, STW-A, STOW-A, SJW-A, SJOW-A, SJTW-A. or SJTOW-A.
6 - English
FEATURES
PRODUCT SPECIFICATIONS
Dual Power Source ....................................... 18 Volt Battery
or 120 Volts, AC only, 60Hz
Output ..................................................30,000–60,000 BTU
Fuel Source ..................................... Propane (not included)
TOOLS NEEDED
The following tools (not included) are needed for assembly and making adjustments: Adjustable wrench
ASSEMBLY
UNPACKING
This product requires assembly. Carefully remove the tool and any accessories from the
box. All items listed in the Includes section must be included at the time of purchase.
WARNING:
Items in this Assembly section are not assembled to the product by the manufacturer and require customer installation. Use of a product that may have been improperly assembled could result in serious personal injury.
If any parts are damaged or missing, please call
1-866-539-1710 for assistance.
WARNING:
If any parts are damaged or missing do not oper­ate this product until the parts are replaced. Use of this product with damaged or missing parts could result in serious personal injury.
WARNING:
Do not attempt to modify this product or create accessories or attachments not recommended for use with this product. Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury.
USING PROPANE (LIQUID PROPANE ALSO CALLED LIQUID PETROLEUM)
Propane is highly flammable and may ignite unexpectedly when mixed with air. The propane cylinder used with this forced air heater must meet the following requirements:
Constructed and marked in accordance with the Speci-
fications for LP Gas Cylinders of the U.S. Department
of Transporation (D.O.T.) or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres, and Tubes
for Transportation of Dangerous Goods; and Commission. Measurements: 12 in. diameter x 18 in. tall with 20 lb.
maximum capacity. Cylinder valve must have: — Cylinder connection device (Type
1) compatible with the connector
for the propane heater — Safety relief valve — UL listed Overfill Protection
Device (OPD). This OPD safety feature is identified
by a unique triangular handwheel. Use only propane
cylinders with this type of valve. Arranged for vapor withdrawal and include collar to pro-
tect propane cylinder valve. Always keep propane cylinder in upright position during use, transport, or storage.
OPD HANDWHEEL
TESTING THE PROPANE CYLINDER
See Figure 1, page 12.
Make sure the propane cylinder is disconnected from the
propane hose and regulator.
Using a clean paint brush and a 50/50 mixture of mild
soap and water, brush soapy solution over areas indicated by arrows in figure 1.
“Growing” bubbles indicate a leak. Do not use or move
the propane cylinder. Contact a gas supplier or the fire department!
If you see, smell, or hear the hiss of escaping gas from
the propane cylinder:
• Move away from propane cylinder
• Do not attempt to correct the problem yourself
• Call your local fire department If no leaks are present, you may proceed to install and
connect the propane cylinder.
7 - English
ASSEMBLY
CONNECTING THE PROPANE CYLINDER
See Figures 2 - 5, pages 12 - 13.
To connect:
Using an adjustable wrench (not provided), screw the
open end of the propane hose to the propane inlet on the heater. Tighten securely.
NOTE: For first time use, remove the rubber protector
cap that protects the propane inlet during shipment.
Make sure the handwheel on the propane cylinder is in
its full off position, then remove the cap from the cylinder valve.
Hold the regulator firmly and insert the nipple into the
cylinder valve.
NOTE: Nipple must be centered in the cylinder valve. Holding coupling nut and regulator as shown, turn cou-
pling nut counterclockwise and tighten by hand, taking care not to cross-thread the connection. Do not use tools.
NOTE: The regulator threads are left handed. The
regulator will seal in the cylinder valve resulting in some resistance. An additional one-half to three-quarters turn is required to complete the connection. If you cannot complete the connection, disconnect and repeat the above two steps. If you still cannot complete the connection, DO NOT use this regulator!
Inspect valve connection port and regulator. Look for any
damage or debris. Remove any debris. Inspect hose for damage. Never attempt to use damaged or plugged
equipment. See your local propane dealer for repairs.
To disconnect:
Hold regulator firmly and turn coupling nut clockwise to
remove.
Place cap on cylinder valve outlet whenever the cylinder
is not in use.
NOTE: Only install on the cylinder valve outlet the type of
cap that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
TESTING VALVES, HOSE, AND REGULATOR FOR LEAKS
DANGER:
DO NOT smoke or use an open flame during leak test. If a leak is present, the gas could ignite and result in serious personal injury.
WARNING:
To avoid serious personal injury, always check for gas leaks any time the propane cylinder is discon­nected and then reconnected.
Connections on the hose and regulator were tested at the factory to ensure no gas leaks were present. However, ship­ping and handling could loosen connections. As a safety precaution:
Turn the propane heater OFF ( O ). Make sure the regulator is properly connected to the
propane cylinder.
Turn handwheel counterclockwise to open the cylinder
valve.
NOTE: If you hear a rushing sound, immediately turn off
the cylinder valve. This sound means there is a major leak at the connection. Correct the problem before proceeding.
Using a clean paint brush and a 50/50 mixture of mild
soap and water, brush soapy solution over all the con­nections and fittings on the product and at the propane cylinder.
“Growing” bubbles indicate a leak. Close the cylinder
valve then retighten all connections.
NOTE: If leaks cannot be stopped, do not try to repair.
Call for replacement parts.
If you are not using the propane heater immediately after
the leak test, close the cylinder valve by turning the valve clockwise.
8 - English
OPERATION
WARNING:
Do not allow familiarity with tools to make you careless. Remember that a careless fraction of a second is sufficient to inflict serious injury.
WARNING:
Do not use any attachments or accessories not recommended by the manufacturer of this tool. The use of attachments or accessories not recom­mended can result in serious personal injury.
INSTALLING/REMOVING POWER CORD (NOT INCLUDED)
See Figure 7, page 13.
Insert the female end of a 16 AWG rated outdoor exten-
sion cord into the product as shown.
Connect the male end of the extension cord to the power
source.
Make sure the extension cord is secured before beginning
operation.
STARTING/STOPPING THE HEATER
See Figure 8, page 13.
WARNING:
Risk of fire. Never position heater at a downward angle or towards combustible materials. This heater must be located away from combustible surfaces by no less than 24 inches from rear and sides of heater and 72 inches from above and front outlet of heater. Heater must be placed on a level surface and the flow of combustion and ventilation air not be obstructed.
APPLICATIONS
You may use this tool for the purpose listed below: General heating of outdoor spaces and most construction
sites with adequate ventilation
NOTICE:
This product is designed to be powered by either a RIDGID 18V battery pack (DC mode) or by electric power (AC mode). Either power source can be used by installing an approved battery pack or power cord into the product as described in this manual.
INSTALLING/REMOVING BATTERY PACK
See Figure 6, page 13.
Insert the battery pack into the product as shown. Make sure the latches on each side of the battery pack
snap into place and the battery pack is secured before
beginning operation. Depress the latches to remove the battery pack. For complete charging instructions, see the operator’s manu-
als for your battery pack and charger.
WARNING:
Always remove battery pack or unplug power cord from your product when you are assembling parts, making adjustments, cleaning, or when not in use. Removing battery pack or unplugging power cord will prevent accidental starting that could cause serious personal injury.
WARNING:
Position heater properly before use. Locate heater on stable and level surface if heater is running and at least (USA) 7 ft. (2.13 m) and (CAN) 10 ft (3 m) from and not directed toward LP (propane) containers.
The heater should be inspected before each use, and at least annually by a qualified service person.
To start:
Make sure the propane tank is properly connected, a
leak test has been performed, and the tank valve is fully turned on.
NEVER direct the heater toward the propane tank. Posi-
tion the propane tank behind the heater with the propane hose fully extended to it’s longest length.
Connect the heater to a power cord or approved battery
pack.
Press the on/off button. The LED will light solid, the fan
will start, and the ignitor will begin clicking.
Within 15 seconds, press and hold the gas/ignitor valve
button for five seconds to lock the gas valve in the on position.
Release the gas/ignitor valve button and the burner should
remain lit.
NOTE: If the burner doesn’t remain lit, wait 30 seconds
and repeat the starting steps, ensuring the gas/ignitor valve button is pressed for at least 5 seconds to lock the gas valve in the on position. If it still fails to ignite, check fuel level in the propane cylinder.
To stop:
Press the on/off button. The heater will automatically shut
down.
Turn the handwheel on the propane cylinder to the fully
off position.
Remove the regulator from the propane cylinder and
replace the cap on the cylinder.
Remove the power cord or battery from the unit.
9 - English
OPERATION
TEMPERATURE CONTROL
See Figure 8, page 13.
The temperature control adjusts from 30,000 to 60,000 BTU. To increase the temperature, turn the temperature control
knob clockwise. For a lower temperature, turn the temperature control
knob counterclockwise.
AUTO SHUT OFF
The unit will automatically shut off during any of the follow­ing conditions:
Flame out — If the propane tank is empty or the flame is
accidently extinguished.
Over temperature — If the flow of air becomes blocked
or the temperature inside the unit is too high, the unit will automatically shut off and the green LED will flash.
Low voltage — such as a power outage or a low battery.
STORAGE
Always remove the propane cylinder, battery pack, and/or power cord from the unit when storing. Always store the unit indoors.
NOTE: MAINTENANCE AND ILLUSTRATIONS START ON PAGE 11 AFTER
FRENCH AND SPANISH LANGUAGE SECTIONS.
These products have a 90-Day Satisfaction Guarantee Policy, as well as a
For Warranty and Policy details, please go to www.RIDGID.com
Three-year Limited Warranty.
or call (toll free) 1-866-539-1710.
10 - English
Loading...
+ 22 hidden pages