RIDGID 70808 User manual

Page 1
WARNING!
Read this Operator’s Man­ual carefully before using this tool. Failure to under­stand and follow the con­tents of this manual may result in electrical shock, fire, and/or serious per­sonal injury.
Operator’s Manual
TM
TM
With Technology
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 2
Table of Contents
Introduction
Regulatory Statements ............................................................................................. 3
Safety Symbols ......................................................................................................... 3
General Safety Rules
Work Area Safety ...................................................................................................... 4
Electrical Safety ........................................................................................................ 4
Personal Safety ........................................................................................................ 4
Equipment Use and Care ......................................................................................... 5
Pre-Operation Inspection .......................................................................................... 6
See Snake microReel APX Overview
Description................................................................................................................ 7
Specifications ........................................................................................................... 8
Components ............................................................................................................. 9
Specific Safety Information
microReel Safety .....................................................................................................10
Operating Instructions
Placement ................................................................................................................11
Opening the microReel Case ..................................................................................11
Installing the Drum.................................................................................................. 12
Inspection Overview ............................................................................................... 12
Pipe Guides ............................................................................................................ 13
Removing the Slip Ring Assembly .......................................................................... 13
Maintenance and Support
Cleaning ................................................................................................................. 14
Maintaining Components ........................................................................................ 14
Disposal .................................................................................................................. 14
Appendix
Appendix A: Reinserting the Push Cable ................................................................ 15
*Original Instructions – English
2 – English – microReel APX
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 3
Introduction
The warnings, cautions, and instruc-
tions discussed in this manual can­not cover all possible conditions and situations which may occur. It must
be understood by the operator that common sense and caution are fac-
tors that cannot be built into this product, but must be supplied by the operator.
Regulatory Statements
The EC Declaration of Conformity (999-995-232.10) will accompany this manual as a separate docu­ment when required.
This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harm­ful interference, and (2) this device must accept any interference re­ceived, including interference that may cause undesired operation.
UK Importer Ridge Tool UK (RIDGID) 44 Baker Street London W1U 7AL, UK
Safety Symbols
In this manual and on the product, safety symbols and signal words are used to com­municate important safety information. This section is provided to improve understand­ing of these signal words and symbols.
This is the safety alert symbol. It is used to alert you to potential per­sonal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE indicates informa­tion that relates to the pro­tection of property.
This symbol means read the man­ual carefully before using the equipment. The manual contains important information on the safe and proper operation of the equip­ment.
This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of eye injury.
This symbol indicates the risk of electrical shock.
microReel APX – English – 3
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 4
General Safety Rules
WARNING
Read all safety warnings and instruc­tions. Failure to follow the warnings and instructions may result in electrical shock, fire, and/or serious injury.
SAVE THESE INSTRUCTIONS!
Work Area Safety
• Keep your work area clean and well lit.
Cluttered or dark areas invite accidents.
• Do not operate equipment in explo-
sive atmospheres, such as in the presence of flammable liquids, gases, or dust. Equipment can create sparks
which may ignite the dust or fumes.
• Keep children and bystanders
away while operating equipment.
Distractions can cause you to lose con­trol.
• Avoid traffic. Pay attention to moving ve-
hicles when using on or near roadways. Wear high-visibility clothing or reflector vests.
Electrical Safety
• Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges, and refrigerators.
There is an increased risk of electrical shock if your body is earthed or ground­ed.
• Do not expose equipment to rain or wet conditions. Water entering equip­ment will increase the risk of electrical shock.
• Keep all electrical connections dry and off the ground. Touching equip­ment or plugs with wet hands can in­crease the risk of electrical shock.
• Do not abuse the cord. Never use the
cord for carrying, pulling, or unplugging the power tool. Keep cord away from heat, extreme cold, oil, sharp edges, and moving parts. Damaged or entan­gled cords increase the risk of electrical shock.
• If operating equipment in a damp lo-
cation is unavoidable, use a ground fault circuit interrupter (GFCI) protect­ed supply. Use of a GFCI reduces the
risk of electrical shock.
Personal Safety
• Stay alert, watch what you are doing, and use common sense when oper­ating equipment. Do not use equip-
ment while you are tired or under the in­fluence of drugs, alcohol, or medication. A moment of inattention while operating equipment may result in serious injury.
• Dress properly. Do not wear loose cloth- ing or jewelry. Loose clothes, jewelry, and long hair can be caught in moving parts.
• Practice good hygiene. Use hot, soapy water to wash hands and other body parts exposed to drain contents after handling or using drain inspection equip­ment. To prevent contamination from toxic or infectious material, do not eat or smoke while operating or handling drain inspection equipment.
• Always use appropriate personal pro-
tective equipment when handling and using equipment in drains. Drains may
contain chemicals, bacteria, and other substances that may be toxic, infec­tious, and cause burns or other issues. Appropriate personal protective equip­ment always includes safety glasses and may include a dust mask, hard hat, hear­ing protection, drain cleaning gloves or mitts, latex or rubber gloves, face shields, goggles, protective clothing, respirators, and steel toed, non-skid footwear.
• If using drain cleaning equipment and
drain inspection equipment at the same time, wear RIDGID drain clean­ing gloves. Never grasp the rotating
4 – English – microReel APX
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 5
drain cleaning cable with anything else, including other gloves or a rag which can become wrapped around the cable and cause hand injuries. Only wear latex or rubber gloves underneath RIDGID drain cleaner gloves. Do not use damaged drain cleaning gloves.
Equipment Use and Care
• Do not force equipment. Use the cor-
rect equipment for your application. The correct equipment does the job better and more safely.
• Do not use equipment if the power switch does not turn it on and off. Any equipment that cannot be controlled with the power switch is dangerous and must be repaired.
• Disconnect the plug from the power
source and/or the battery pack from the equipment before making adjust­ments, changing accessories, or stor­ing. Preventive safety measures reduce
the risk of injury.
• Store idle equipment out of the reach
of children and do not allow per­sons unfamiliar with the equipment or these instructions to operate the equipment. Equipment can be danger-
ous in the hands of untrained users.
• Maintain equipment. Check for mis- alignment or binding of moving parts, missing parts, breakage of parts, and any other condition that may affect the equipment’s operation. If damaged, have the equipment repaired before use. Many accidents are caused by poorly main­tained equipment.
• Do not overreach. Keep proper footing and balance at all times. This enables better control of the equipment in unex­pected situations.
• Use the equipment and accessories
in accordance with these instructions, taking into account the working con­ditions and the work to be performed.
Use of the equipment for operations
different from those intended can result in hazardous situations.
• Use only accessories that are rec-
ommended by the manufacturer for your equipment. Accessories that may
be suitable for one piece of equipment may become hazardous when used with other equipment.
• Keep handles dry, clean, and free from oil and grease. Clean handles give bet­ter control of the equipment.
microReel APX – English – 5
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 6
Pre-Operation Inspection
WARNING
To reduce the risk of serious injury from electrical shock or other causes, and to prevent damage to your equipment, in­spect all equipment and correct any problems before each use.
To inspect all equipment, follow these steps:
1. Power off your equipment.
2. Disconnect and inspect all cords, ca­bles, and connectors for damage or modification.
3. Clean any dirt, oil, or other contami­nation from your equipment to ease inspection and to prevent it from slip­ping from your grip during transporta­tion or use.
4. Inspect your equipment for any broken, worn, missing, misaligned, or binding parts, or any other condition which might prevent safe, normal operation.
5. Refer to the instructions for all other equipment to inspect and make sure it is in good, usable condition.
6. Check your work area for the following:
• Adequate lighting.
• The presence of flammable liq­uids, vapors, or dust that may ig­nite. If present, do not work in area until sources have been identified and corrected. The equipment is not explosion proof. Electrical connections can cause sparks.
• A clear, level, stable, and dry place for the operator. Do not use the equipment while standing in water.
7. Examine the job to be done and de­termine the correct equipment for the task.
8. Observe the work area and erect bar­riers as necessary to keep bystanders aw ay.
See additional product specific safe­ty information and warnings starting on
10.
6 – English – microReel APX
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 7
See Snake microReel APX Overview
Description
The RIDGID® See Snake® microReel™ APX™ is a portable and customizable diagnostic camera reel with enhanced imaging fea­tures.
The stiffer push cable makes the microReel ideal for inspecting longer runs in pipes that are 38mm to 102 mm [1.5in to 4 in]. The included kickstand lets you set up the mi­croReel in the optimal position for stability while pushing or retrieving the cable.
The microReel features a built-in sonde in the camera head that can be located with a utility locating receiver to find points of inter­est in the pipe.
The microReel is compatible with all SeeSnake monitors. The CSx Via™ mobile inspection device easily connects to the mi­croReel APX via the slip-ring cavity.
APX Features
The microReel APX is equipped with an auto image flip feature. When connected to a SeeSnake CSx series device, the mi­croReel APX flips your onscreen image as the camera rotates through the pipe, ensur­ing your image remains oriented upright. An on-screen icon indicates the vertical orien­tation with respect to the image.
TruSense Technology Description
The microReel APX includes a TruSense technology-enabled camera. TruSense technology establishes a two-way commu­nication link between the camera head and a connected CSx series Wi-Fi enabled mon­itor. TruSense features advanced on-cam­era sensors that convey valuable informa­tion about the in-pipe environment.
Included TruSense-Enabled Sensors
TiltSense™
The TiltSense inclinometer measures the camera’s degree of tilt and displays it on a CSx series Wi-Fi enabled monitor, giving you a useful indicator of the camera’s angle as it lays inside the pipe.
High Dynamic Range Image Sensor
The HDR sensor expands the camera’s dynamic range, allowing a greater ratio of bright and dark areas to be displayed in the same image at the same time without re­ducing visibility. The result is superior clarity and detail, allowing you to quickly and easily identify problem areas.
microReel APX – English – 7
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 8
Specifications
Specifications
Weight 5.8 kg [12.7 lbs]
Dimensions
Length 337 mm [13.3 in]
Depth 224 mm [8.8 in]
Height 411 mm [16.2 in]
Drum diameter 305 mm [12 in]
TruSense Camera
Length
26 mm [1 in]* 37 mm [1.5 in]**
Diameter 25 mm [1 in]
Resolution 640 × 480 pixels
Sonde
Type Integrated
Frequency 512 Hz
Distance Measurement
Type TruSense Counter
Data Communication
Two-Way
Push Cable
Length 30 m [100 ft]
Diameter 6.7 mm [0.27 in]
Fiberglass core diameter
Minimum bend radius
Pipe Capacity
System Cable Length
§
3 mm [0.12in]
64 mm [2.5 in]
38 to 101 mm [1.5 to 4 in]
3 m [10 ft]
Operating Environment
0°C to 46°C
Temperature
Storage temperature
‡
[32°F to 115°F]
-20°C to 70°C [-4°F to 158°F]
Ingress protection (without
IP×5 monitor) Relative
humidity
5 to 95 percent
Altitude 4,000m [13,123ft]
Camera depth rating
* Measured from lens to spring.
** Measured from lens to end of threads.
§ Actual pipe capacity depends on pipe conditions.
‡ While the camera can function in ex­treme temperatures, some image quality changes may occur.
Waterproof to
100m [328.1ft]
Standard Equipment
• See Snake microReel
• Ball guides
• Operator’s manual
8 – English – microReel APX
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 9
Components
SeeSnake System Cable
System Cable Wrap
Push Cable Guide
TruSense Counter
Carry Handle
Case Latch
Camera Clip
Slip Ring
Module
Kickstand
Serial Number Label
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Kickstand
microReel APX – English – 9
Page 10
Specic Safety Information
WARNING
This section contains important safety information that is specific to the RIDGID See Snake microReel. Read these pre­cautions carefully before using the equipment to reduce the risk of electrical shock, fire, and/or serious injury.
SAVE ALL WARNINGS AND
INSTRUCTIONS FOR FUTURE
REFERENCE!
microReel Safety
• Read and understand this manual, the digital reporting monitor’s manu­al, and the instructions for any other equipment you are using before oper­ating the equipment. Failure to follow all
instructions may result in property dam­age and/or serious injury. Keep this man­ual with the equipment for future use.
• Operating the equipment while in
water increases the risk of electri­cal shock. Do not operate the system
if operator or equipment are standing in water.
• The equipment is not designed to pro-
vide high voltage protection and iso­lation. Do not use where a danger of
high voltage contact is present.
• To prevent damage to the equipment
and to decrease the risk of injury, do not expose the equipment to mechan­ical shocks. Exposure to mechanical
shocks can damage equipment and in­crease the risk of serious injury.
• Always use appropriate personal pro-
tective equipment when handling and using equipment in drains. Wear
appropriate protective equipment such as latex or rubber gloves, goggles, face shields, and respirators when inspect­ing drains that might contain hazard­ous chemicals or bacteria. Always wear eye protection to protect against dirt and other foreign objects.
• Ensure the push cable is secured in-
side the drum to prevent the push cable from unwinding itself if the drum is removed from the case or if the case is left open with the drum in­side. If the push cable unwinds, do not
manually twist or force the push cable back into the non-rotating drum. The twisting and bending of the push cable that results from forcing it into the drum without the use of the outer case to ro­tate it will damage the push cable. See Appendix A for instructions on reinsert­ing the push cable if it has unwound itself from the drum.
10 – English – microReel APX
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 11
Operating Instructions
Placement
Set up your microReel near the pipe en­trance so you can manipulate the push cable while viewing the display. Use the kickstand to position the microReel so that it does not tip during use.
Opening the microReel Case
WARNING
Make sure the camera is completely in­side the drum before unlatching and opening the microReel case. Do not open the microReel case while the cam­era is stored in the camera clip. If the camera is not in the drum, the push cable can unwind and cause damage or seri­ous injury.
Open the microReel case to route the cam­era, replace the drum, rewind the push cable, and to maintain and clean the system.
1. Set the unit on a level surface and lay it on its back.
2. Unfasten the case latches on either side of the microReel.
Case Latch
3.
Carefully open the front case and lo­cate the camera head in the push cable drum.
4. Route the camera head out through the push cable guide in the front of the case.
5. Secure the camera head in the clip.
6. Close and relatch the case.
microReel APX – English – 11
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 12
Installing the Drum
The microReel case gives you the ability to swap out the drum when the job requires a different push cable and camera combi­nation. Either microReel drum can be in­stalled in the microReel case, as well as the drums on the SeeSnake microDrain™ and nanoReel™ systems.
To install the drum, follow these steps:
1. Open the microReel case and remove the drum.
2. Place the drum you want to use in the microReel case.
3. Make sure the product name label faces up.
4. Spin the drum to make sure it rotates freely.
5. Close and lock the case.
Inspection Overview
To perform a pipe inspection, connect any See Snake monitor to the reel, power on the system, push the push cable through the pipe, and observe the display.
For advanced inspection options, such as capturing media, locating the sonde, tracing the push cable, and delivering reports, refer to the manual that comes with your monitor.
Connecting to the Monitor
Connect the system cable to the monitor by aligning the connector guide pin with the socket and pushing the connector straight in.
NOTICE
Socket
Only twist the outer locking sleeve. Never bend or twist the connector.
Guide Pin
Connector Ridge
12 – English – microReel APX
Outer Locking Sleeve
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 13
Connecting to the CSx Via
The CSx Via Wi-Fi inspection device can be connected to the microReel through the slip­ring cavity. Remove the slip-ring assembly from the microReel and install the CSx Via into the slip-ring cavity.
For more instructions on installing the CSx Via, refer to the operator’s manual.
Retrieving the Camera
Pull the push cable back out of the pipe with slow, steady force and feed small lengths back into the drum. Wipe the push cable with a paper towel or rag as you retrieve it.
NOTICE
Do not exert excessive force or pull at sharp an­gles. Feeding longer lengths or forcing the push cable may cause it to loop, kink, or break.
Pipe Guides
Pipe guides center the camera in the pipe, improve picture quality, and help keep the lens clear. Use pipe guides when possible to reduce wear and tear on the camera sys­tem.
Removing the Slip Ring Assembly
1. Disconnect the system cable from the reporting monitor and remove the mon­itor from the docking system.
2. Unwrap the system cable from the cable wraps.
3. Pop the frame cable anchor off the frame and unhook the system cable from the frame hook.
4. Turn the slip-ring dial counter-clock­wise to the unlocked position .
5. Pull straight out.
NOTICE
Do not touch the contact pins inside the slip-ring dial. Stressing the con­tact pins can cause them to break.
microReel APX – English – 13
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 14
Maintenance and Support
Cleaning
Clean your system with rags and a soft nylon brush. If desired, a mild detergent or disinfectant can be used. Do not use sol­vents or high pressure water to clean any part of the system.
Maintaining Components
Camera Head
Scratches on the camera have a minimal ef­fect on its performance. Do not use scraping tools or sand the camera to remove scratch­es.
Push Cable
Run a rag over the push cable and visually inspect it for cuts and abrasions while push­ing it back into the drum. Replace or repair the push cable if the outer jacket is cut or abraded.
Storage
The microReel must be stored in a dry, se­cure area between -20°C and 70°C [-4°F and 158°F]. Store your equipment in a locked area out of the reach of children and people unfamiliar with its purpose.
Disposal
Parts of your system contain valuable mate­rials that can be recycled. There are compa­nies that specialize in recycling that may be found locally. Dispose of the components in compliance with all applicable regulations. Contact your local waste management au­thority for more information.
EC Countries: Do not dis­pose of electrical equipment with household waste!
According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment and its implementation into national legislation, electrical equip­ment that is no longer usable must be collected separately and disposed of in an environ­mentally correct manner.
Battery Disposal EC Countries: Defective or used batteries
must be recycled according to the guideline 2006/66/EEC.
14 – English – microReel APX
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Page 15
Appendix
Appendix A: Reinserting the Push Cable
NOTICE
Follow these instructions to reinsert the push cable if it has unwound from the drum.
1. Seat the drum in the case before rein­serting the push cable.
2. If space permits, uncoil and straighten the entire length of push cable on the ground.
Do not use excessive force when attempting to rewind the push cable into the drum. Feeding longer lengths or forcing the push cable may cause it to loop, kink, or break.
If the push cable becomes twisted or bent, stop rewinding and untwist it be­fore continuing.
4. Ensure the drum rotates in the case as the push cable rewinds. To avoid dam­aging the push cable, keep one hand close to the drum when rewinding the push cable to ensure that the drum ro­tates freely.
5. Gently route the camera head through the push cable guide.
If replacing the camera head, only pull up on the portion of the cable that contains the spring to avoid bending or breaking the push cable.
3. Using both hands, begin to rewind the push cable into the drum. If the push cable cannot be laid out straight, use extreme care when rewinding the push cable. Ensure the push cable does not bend or get caught on or underobjects.
microReel APX – English – 15
Find Quality Products Online at: [email protected]
www.GlobalTestSupply.com
Loading...