Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
Product Catalog No. ............... : 32803, 32808, 32813, 32818
Recommended Use................ : Thread Cutting
Restrictions on Use…………..: Use in the manufacturing process only
Company Name ..................... : Ridge Tool Company
Address .................................. : 400 Clark Street
: Elyria, Ohio 44035-6001
Telephone .............................. : 1-800-519-3456 (USA) (8:00 am – 5:00 pm EST, M-F)
Emergency Telephone ........... : call 9-1-1 or local emergency number
Website ………………………..: www.RIDGID.com
Issue Date .............................. : June 23, 2015
This product is classified as not hazardous per US OSHA 29CFR 1910.1200 (HazCom
2012) and Canada’s Hazardous Products Regulations (WHMIS 2015). GHS Label Elements: Not applicable
Component: CAS # % By Weight Mineral Oil Confidential 60-100% Zinc Compound Confidential 1-5%
This product does not contain silicone or chlorinated additives.
Specific chemical identities and/or exact percentages have been withheld as trade secrets.
Page 2
Page 2 of 9
Section 4
– First Aid Measures
Section 5
– Fire Fighting Measures
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
INGESTION:
Rinse mouth thoroughly. Call a Poison Center or doctor if you feel unwell. Do NOT induce vomiting.
INHALATION:
Move to fresh air. Call a Poison Center or doctor if you feel unwell.
SKIN CONTACT:
Remove contaminated/saturated clothing and shoes. Wash contact areas with soap and water. If skin irritation occurs: Get medical advice/attention.
EYE CONTACT:
Flush thoroughly with water. If irritation occurs, get medical assistance. Continue to rinse for at least 15 minutes.
MOST IMPORTANT SYMPTOMS/EFFECTS, ACUTE AND DELAYED
Symptoms:
No data available.
INDICATION OF IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT NEEDED
Treatment:
Get medical attention as appropriate or if symptoms persist
GENERAL FIRE HAZARDS:
No unusual fire or explosion hazards noted.
SUITABLE (AND UNSUITABLE) EXTINGUISHING MEDIA
Suitable extinguishing media: Unsuitable extinguishing media:
SPECIFIC HAZARDS ARISING FROM THE CHEMICAL:
Heat may cause the containers to pressurize and possibly rupture. During fire, gases hazardous to health may be formed.
No data available. Do not use water jet as an extinguisher, as this will spread the fire.
Page 3
Page 3 of 9
Section 6
– Accidental Release Measures
Section 7
– Handling And Storage
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
SPECIAL PROTECTIVE EQUIPMENT AND PRECAUTIONS FOR FIREFIGHTERS
Special firefighting procedures:
No data available.
Special protective equipment for fire-fighters:
Firefighters must use standard protective equipment appropriate for Industrial fires.
PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:
See Section 8 of the SDS for Personal Protective Equipment. Do not handle damaged containers or spilled material unless wearing appropriate protective clothing. Keep unauthorized personnel away. Ensure adequate ventilation.
METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP:
Absorb with sand or other inert absorbent. Stop the flow of material, if this is without risk.
ENVIRONMENTAL PRECAUTIONS:
Avoid release to the environment. Do not contaminate water sources or sewer. Prevent further leakage or spillage if safe to do so and protect against releases into the environment. Remediate as appropriate.
PRECAUTIONS FOR SAFE HANDLING:
Observe good industrial hygiene practices. Wear appropriate personal protective equipment. Do not expose to intense heat as product may expand and pressurize container.
CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES:
Store in original tightly closed container. Avoid contact with oxidizing agents. Store away from incompatible materials.
SHELF LIFE: 720 days
Page 4
Page 4 of 9
Section 8
– Exposure Controls / Personal Protection
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
EXPOSURE LIMITS:
Chemical name type Exposure Limit Values Source
Mineral oil - Mist. PEL 5 mg/m3
US. OSHA Table Z-1 Limits for Air
Contaminants (29 CFR 1910.1000)
(02 2006)
PROTECTIVE MEASURES:
Use personal protective equipment as required.
RESPIRATORY PROTECTION:
In case of inadequate ventilation use suitable respirator. Seek advice from supervisor on the company's respiratory protection standards.
EYE PROTECTION:
Wear safety glasses with side shields (or goggles).
SKIN AND BODY PROTECTION:
Wear protective clothing appropriate for the risk of exposure. Contact health and safety professional or manufacturer for specific information.
HYGIENE MEASURES:
Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing to remove contaminants. Contaminated work clothing should not be allowed out of the workplace. Discard contaminated footwear that cannot be cleaned. Avoid contact with skin, eyes, and clothing.
Page 5
Page 5 of 9
Section 9
– Physical And Chemical Properties
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
Appearance Physical State Liquid Form No data available Color Amber Odor Mild petroleum Odor Threshold No data available pH No data available Melting point/freezing point No data available Initial boiling point and boiling range No data available Flash point 177 oC (351 oF) Evaporation rate No data available Flammability (solid, gas) No data available Upper/lower limit on flammability or explosive limits Flammability limit - upper (%) No data available Flammability limit - lower (%) No data available Explosive limit – upper (%) No data available Explosive limit – lower (%) No data available Vapor pressure No data available Vapor density No data available Relative density 0.9297 Solubility(ies) Solubility in water Insoluble Solubility (other) No data available Partition coefficient (n-octanol/water) No data available Auto-ignition temperature No data available Decomposition temperature No data available Viscosity 44.5 mm2/s (40 oC, measured) VOC 1.1 g/l
Page 6
Page 6 of 9
Section 10
– Stability And Reactivity
Section 11
– Toxicological Information
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
REACTIVITY:
Not reactive during normal use.
CHEMICAL STABILITY: No data available.
POSSIBILITY OF HAZARDOUS REACTIONS: None under normal conditions.
CONDITIONS TO AVOID:
Avoid heat or contamination.
INCOMPATIBLE MATERIALS: No data available.
HAZARDOUS DECOMPOSITION PRODUCTS:
Contains a component which may release flammable substances, including trimethylpentene, by distillation in systems with solvent recovery. This may lead to accumulation in the solvent circuit.
INFORMATION ON LIKELY ROUTES OF EXPOSURE
Ingestion:
May be ingested by accident. Ingestion may cause irritation and malaise.
Inhalation:
Inhalation is the primary route of exposure. In high concentrations, vapors, fumes or mists may irritate nose, throat and mucus membranes.
Skin Contact:
Prolonged skin contact may cause redness and irritation.
Eye contact:
Eye contact is possible and should be avoided.
Page 7
Page 7 of 9
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
SYMPTOMS RELATED TO THE PHYSICAL, CHEMICAL AND TOXICOLOGICAL CHARACTERISTICS
Ingestion:
No data available.
Inhalation:
No data available.
Skin Contact:
No data available.
Eye contact:
No data available.
INFORMATION ON TOXICOLOGICAL EFFECTS
Acute toxicity
Oral Product:
ATEmix (): 2000 - 5000 mg/kg
Dermal Product:
ATEmix (): 2000 - 5000 mg/kg
Inhalation Product:
Not classified for acute toxicity based on available data.
Repeated dose toxicity Product:
No data available.
Skin Corrosion/Irritation Product:
No data available.
Serious Eye Damage/Eye Irritation Product:
No data available.
Respiratory or Skin Sensitization Product:
No data available.
Carcinogenicity Product: No data available.
IARC Monographs on the Evaluation of Carcinogenic Risks to Humans:
No carcinogenic components identified
US. National Toxicology Program (NTP) Report on Carcinogens:
No carcinogenic components identified
US. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050):
No carcinogenic components identified
Germ Cell Mutagenicity
In vitro Product:
No data available.
In vivo Product:
No data available.
Page 8
Page 8 of 9
Section 12
– Ecological Information
Section 13
– Disposal Consideration
Section 14
– Transportation
Information
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
Reproductive toxicity Product:
No data available.
Specific Target Organ Toxicity - Single Exposure Product:
No data available.
Specific Target Organ Toxicity - Repeated Exposure Product:
No data available.
Aspiration Hazard Product:
No data available.
Other effects:
No data available
GENERAL INFORMATION:
This product has not been evaluated for ecological toxicity or other environmental effects.
DISPOSAL INSTRUCTIONS:
Discharge, treatment, or disposal may be subject to national, state, or local laws. Dispose of waste at an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal. It is the responsibility of the product user or owner to determine at the time of disposal, which waste regulations must be applied.
CONTAMINATED PACKAGING:
Empty containers should be taken to an approved waste handling site for recycling or disposal.
This material is not subject to transport regulations.
Page 9
Page 9 of 9
Section 15
– Regulatory Information
Section 16
– Other Information
Product Name ........................ : RIDGID Endura-Clear Thread Cutting Oil
US FEDERAL REGULATIONS
US. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050)
None present or none present in regulated quantities.
Superfund Amendments and Reauthorization Act of 1986 (SARA)
Hazard categories - None SARA 313 (TRI Reporting)
Chemical Identity
zinc compound 10000 lbs 25000 lbs
Reported threshold for
other users
Reported threshold
for other users
US STATE REGULATIONS
US. California Proposition 65
No component is regulated by CA Prop 65.
Prepared by:. . . . . . . . . . . . Ridge Tool Company
Issue Date: . . . . . . . . . . . . . June 23, 2015
Last Revision Date: . . . . . . . June 23, 2015
RIDGE TOOL BELIEVES THE STATEMENTS, TECHNICAL INFORMATION AND RECOM­MENDATIONS CONTAINED HEREIN ARE RELIABLE BUT THEY ARE GIVEN WITHOUT WARRANTY OR GUARANTEE OF ANY KIND, EXPRESSED OR IMPLIED, AND WE ASSUME NO RESPONSIBILITY FOR ANY LOSS, DAMAGE OR EXPENSE, DIRECT OR CONSEQUENTIAL, ARISING OUT OF THEIR USE.