T
Model:
Finisher for the AD50
echnical
B
ulletin
Date:
15-Sep-97
No:
PAGE: 1/5
1
Subject:
From:
Classification:
The new Finisher (SR710) is being developed as a peripheral for the AD50, which will be
launched this November. This RTB clarifies the differences between the SR700 and the
SR710.
1. Model Name and Machine Code
Brand Name Ricoh NRG Infotec Savin
Machine Code A612-57 A612-62 A612-66 A612-55
Model Name SR710
2. Technical Information
New Product Information
QAC 2nd Field Information Dept.
Troubleshooting
Mechanical
Paper path
Other ( )
All information in the service manual is the same as that for SR700 except for the
following items.
Part information
Electrical
Transmit/receive
Prepared by:
Action required
Service manual revision
Retrofit information
S.Tomoe
1) Increased paper speed at the entrance of the unit
The AD50 copy speed is 50 cpm. So, the paper speed at the entrance of the unit
has been increased from the SR700 (200 mm/s → 250 mm/s). Therefore, the
transport drive motor has been changed.
2) Two grounding plates have been removed
Due to a change in the European Radiation Standard Class (EN55022) of the AD50
from class B to class A, two grounding plates are no longer necessary to install the
unit. Therefore, the installation procedure of the finisher has been changed (refer to
the attached installation procedure).
T
Model:
Finisher for the AD50
echnical
INSTALLATION PROCEDURE
[B]
[B]
[A]
B
ulletin
Date:
15-Sep-97
No:
PAGE: 2/5
1
[C]
A612I502.WMF
[E]
CAUTION
Unplug the power cord before beginning the following procedure.
[F]
[D]
[C]
[D]
A612I503.WMF
1. Remove the strip of tape [A] and the cushions [B].
2. Open the front door and remove the strips of tape [C] and cushions [D].
3. Pull out the staple unit [E].
4. Remove the strip of tape [F].
T
echnical
B
ulletin
PAGE: 3/5
Model:
[A]
[C]
Finisher for the AD50
[B]
A612I508.WMF
Date: 15-Sep-97
[A]
No: 1
[E]
5. Remove the screws [A] from the left cover.
6. Install the front connecting bracket [B] (2 screws— M4 x 12) and the rear connecting
bracket [C] (2 screws— M4 x 12).
7. Attach the mylar strip [D] to the copy exit area, as shown.
NOTE:
8. Attach the cushion [F] to the lower exit plate, as shown.
Carefully align the edge of the cover [E] with the mylar guide.
[F]
[D]