Power Supply Unit for N220 (Ricoh Power Supply Unit Type A,
Savin Power Supply Unit for 9180, Nashua IF3018, infotec Power Supply Unit 9118)
To increase reliability of the optional dc drive board
New Parts
No.
14020951Diode - 12V0 - 21057
Description
Volt/Hz
A.B.C. Q’ty Used
Old →
RankPart No.DescriptionIndex No. Page
New
Inter-
change-
ability
Part needed for replacement by new partParts Catalog
Date of
Modification
Serial Number
16042358Capacitor - 4700µF 50V1 - 11147
16114220Resistor - 22Ω 1/4T ±5%1 - 11177
16114680Resistor - 68Ω 1/4T ±5%1 - 11177
Rank: A : Replace with new parts immediately.B : Replace with new parts at time of repair.C : Replace with new parts at time of overhall.
Interchangeability:
(1) When old and new parts are not mutually interchangeable, use additional parts or an assembly part as indicated in "Parts needed for replacement by new part" to
install the new part.
(2) The mark to the left of the slash indicates whether the old part can be used in the new machine, and the mark to the right indicates whether the new part can be used
in the old machine. x = Not interchangeable o = Interchangeable
MODIFICATION BULLETIN NO. 3 Page 2 of 4ISSUED ON: January 31, ’91
DETAILS OF MODIFICATION
Electrical malfunction of the DF due to electrical noise was found at the factory.
When the duplex unit is pulled out and in, poor connection may occur at CN720 as shown in the following schematics.
Electrical noise may then be generated on the 5V line of the optional dc drive board. The electrical noise causes an electrical
malfunction on the DF. For example, a motor may stay on. The occurrence ratio is expected to be very low.
To prevent the electrical malfunction, the zener diode has been removed and two diodes have been added as shown in the
schematics of the modified optional dc drive board (next page).
When the duplex unit is inserted, if the following
sequence occurs, the current (24V) goes
through the 5V line circuit. This generates
electrical noise.
When inserting the duplex unit;
• Two ground lines are not connected.
• The 24V line is connected first.
• Then, the 5V line is connected
Option DC Drive Board
5V
24V
DF
5V
GND
24V
GND
Duplex Unit
Load
Load
: normal circuit path
: abnormal circuit path
T.Ito, Manager
Copier Technical Support
Optional DC Drive Board Schematics
MODIFICATION BULLETIN NO. 3 Page 3 of 4ISSUED ON: January 31, ’91
CN100-1
CN100-2
CN100-3
CN100-4
10VAC
10VAC
26VAC
26VAC
FU100
FU101
ST100R100Q100
D100
+
C100+C101
ST101R103Q101
+
C104
D100
IC100
R101
R102
D102
IC101
+
C105
: Modified parts
+
C102 C103
+
C106 C107
D101
D103
D104
D105
C108
C109
5.2VDAC
5.2VDAC
GND
GND
24VDAC
24VDAC
GND
GND
CN101-2
CN102-2
CN102-1
CN101-1
CN101-4
CN102-4
CN102-3
CN101-3
MODIFICATION BULLETIN NO. 3 Page 4 of 4ISSUED ON: January 31, ’91
MODEL NAME
Savin Power Supply Unit
for use in 9180 copier
Nashua IF3018115/60Canada, L.AmericaA494-16From First Production
Ricoh Power Supply Unit
Type A
Nashua IF3018220,240/50Europe. etc.A494-25From First Production
infotec Power Suppy Unit
9118Z
Ricoh Power Supply Unit
Type A
V/HzDESTINATIONCODESERIAL NUMBER
115/60USA, CanadaA494-1501200001
115/60USA, CanadaA494-1701200001
220,240/50EuropeA494-2601200001
220,240/50Europe, etc.A494-2701200001