There have been reports from the field of problems with dirty background caused by dust
that accumulates in the optics area. We investigated, and decided to register as a service
part a filter for the optics cooling fan entrance.
The part numbers and the installation method are as follows:
P/N A0249505 Filter Kit - Optics
Component Part Number Description Q’ty
1 A0249506 Filter - 35 x 80 2 pcs
2 A0249507 Filter - 35 x 160 1 pcs
Installation Method
1. Remove the platen cover or DF unit if installed.
2. Remove the upper cover [A] (8 screws).
3. Affix the three filters to the back right side of the upper cover as shown below.
[B] … P/N A0249506 (2 pcs)
[C] … P/N A0249507 (1 pc)
Revision of service manual
Information only
Other
FROM: Reprographic Q.A. Section
MODEL: F12, F13, F23
[A]
[A]
NOTE: There must be no gap between the filter edges [D] and the projections [E] on the
upper cover.
Use these filters only for models F12, F13, F23, F24 and F25.