• HUB Mode connects up to 16 transmitters to one fieldbus
• Quick menu for real and theoretical calibration
• Red LED display with six-digits (8 mm) and six LEDs show
active functions
• Standard DIN rail mounting with power supply and enclosures
• Configurable calibration and setup parameters from keyboard
• Up to three calibration linearization points or three
from the keyboard
• Reading of the net, gross and tare weights, clearing,
semi-automatic and presettable tare, scale switch, setting of
outputs application thresholds
• Diagnostic information via serial port, message display,
printing, setting of APW in counting mode, simulation of key
pressure, Modbus RTU
• Double RS-485 port for a quick network connection
• Printer management on second serial port available
• Multi-range function allows for subdividing the scale capacity
in two, each up to 3,000 divisions
Page 2
SCT-3300
Signal Conditioning Transmitter/Indicator
SCT-3300 Specifications
Power
Excitation Voltage10 VDC, 170 mA, 6 x 350 Ω
Analog Signal Input Range3.5 to 24 mV
Analog Signal Sensitivity
A/D Sample Rate300 Hz
Resolution
Analog Output
(if equipped)
Temperature & Humidity
Dimensions (W x H x D)4.56 in x 3.72 in x 2.4 in (114 mm x 93 mm x 60 mm)
Weight0.5 lb (0.2 kg)
Rating/MaterialDIN rail mount: NEMA Type 1
WarrantyOne-year limited warranty
Input: 20-28 VDC
Power consumption: 8 W
0.1 µV/graduation minimum
1.0 µV/graduation recommended
Internal resolution: 16 million counts
System linearity: ± 0.01% full scale
Optoisolated, 16 bit
0-20 mA, 4-20 mA (max 300 ohm)
0-10 VDC (min 10,000 ohm)
Working temperature: 14° F to 122° F (-10° C to 50° C)
Humidity: 85% non-condensing
INDICATORS / CONTROLLERS
Standard Features
• Powers up to six (350 Ω) load cells in parallel
(with a 24-bit A/D converter)
• A/D converter 24-bit (16,000,000 points)
• 12-bit analog output: 0-20 mA, 4-20 mA, 0-10 V
• Mounting on Omega/DIN rail for back panel or junction box
Internal resolution: 16 million counts
System linearity: ± 0.01% full scale
Optoisolated, 16 bit
0-20 mA, 4-20 mA (max 300 ohm)
0-10 VDC, 0-5 VDC (min 10,000 ohm)
Working temperature: -4° F to 140° F (-20° C to 60° C)
Humidity: 85% non-condensing
SCT converter (W x H x D): 3.54 in x 3.74 in x 2.36 in
(90 mm x 95 mm x 60 mm)
IP67 enclosure (W x H x D): 6.69 in x 5.51 in x 3.74 in
(170 mm x 140 mm x 95 mm)
DIN rail mount: NEMA Type 1
Sealed enclosure: NEMA Type 4/IP67, plastic enclosure, clear
cover, six PG9 cord grips
Input: 12 -24 VDC
Power consumption: 5W
0.1 µV/graduation minimum
1.0 µV/graduation recommended
Internal resolution: 16 million counts
Weight display resolution: 999,999
System linearity: ± 0.01% full scale
Optoisolated, 16 bit
0-20 mA, 4-20 mA (max 300 ohm)
0-10 VDC, 0-5 VDC (min 10,000 ohm)
Backlit graphic LCD, transmissive
128 x 64 pixel resolution, 60 x 32 mm visible area
Five-key tactile keypad
Test, Zero, Tare, Print Menu, Escape, Left and Up, Navigator,
Enter
Working temperature: -4° F to 140° F (-20° C to 60° C)
Humidity: 85% non-condensing
SCT converter (W x H x D): 5.82 in x 3.62 in x 2.36 in
(148 mm x 92 mm x 60 mm)
DIN rail mount: NEMA Type 1
Sealed enclosure: NEMA Type 4/IP67, plastic enclosure, clear
cover, six PG9 cord grips
542
Standard Features
• LCD display, 5 mm, eight-digit
• Powers up to eight (350 Ω) load cells in parallel (with a
24-bit A/D converter)
*How to Order the SCT-2200
Order SCT-2200 transmitter.
Order fieldbus module (HUB mode connects up to 16 transmitters to one fieldbus module).
Order cables: (Number of SCTs — 1) + (1 for Fieldbus).
Indicator, SCT2200 for scale input to be used
with fieldbus module
SCT converter RS 232/485 to EtherNet TCP/IP
and Modbus TCP
Est.
Weight
1 lbConsult
1 lbConsult
Price
SCT-3300
Part Number/Price
Part # Description
Transmitters
188725
Indicator, SCT-3300 four load cell input with
analog output
Est.
Weight
1 lbConsult
Price
Power Supply
Part Number/Price
Part # Description
8879212 VDC 1.2A DIN rail mounted power supply1 lbConsult
119244 24 VDC 1.3
A DIN rail mounted power supply1 lbConsult
Est.
Weight
Price
SCT-10
Part Number/Price
Part # Description
129393 SCT-10 converter with analog output1 lbConsult
129394 SCT-10 converter with analog output in enclosure 1 lbConsult
131129 Installation manual1 lbConsult
Est.
Weight
Price
SCT-20
Part Number/Price
Part #Description
129396 SCT-20 converter with analog output1 lbConsult
129397 SCT-20 converter with DeviceNet
129558 SCT-20 converter with Profibus
129398 SCT-20 converter with EtherNet/IP
132534 SCT-20 converter with EtherNet TCP/IP
156903 SCT-20 converter with Modbus/TCP1 lbConsult
131128 Installation manual1 lbConsult
NTEP Approved
162883 SCT-20 converter with analog outputConsult
162886 SCT-20 converter with EtherNet/IPConsult
162887 SCT-20 converter with EtherNet TCP/IPConsult
™
™
DP1 lbConsult
™
™
Est.
Weight
1 lbConsult
1 lbConsult
1 lbConsult
Price
SCT-30
Part Number/Price
Part # Description
156794 SCT-30 converter with analog output1 lbConsult
156834 SCT-30 converter with analog output in enclosure 1 lbConsult
131129 Installation manual1 lbConsult
Est.
Weight
Price
SCT-40
Part Number/Price
Part # Description
170470 SCT-40 with analog output1 lbConsult
170471 SCT-40 with DeviceNet1 lbConsult
170472 SCT-40 with Profibus1 lbConsult
170473 SCT-40 with EtherNet/IP1 lbConsult
170474 SCT-40 with TCP/IP1 lbConsult
170475 SCT-40 with Modbus/TCP1 lbConsult
170476 SCT-40 with Profinet/I/O 1 lbConsult
131128 Installation manual1 lbConsult