Rice Lake Weighing Systems SCT-1100, SCT-2200 Specifications

Page 1
SCT-1100 and SCT-2200 Advanced Series
Signal Conditioning Transmitter/Indicator
INDICATORS / CONTROLLERS
SCT-1100 Specifications SCT-2200 Specifications
Power
Excitation Voltage 5VDC, 120 mA, 8 x 350 Ω 5 VDC, 120 mA, 8 x 350 Ω Analog Signal Input Range ± 39 mV ± 39 mV
Analog Signal Sensitivity
A/D Sample Rate
Resolution
Digital Inputs/Outputs
Serial Port (1) RS-485, (1) RS-232 (1) RS-485, (1) RS-232
Analog Output (if equipped)
Display
www.ricelake.com | Phone: 800-472-6703
Keyboard
Temperature & Humidity
Dimensions (W x H x D)
Weight 1 lb (0.5 kg) 1 lb (0.5 kg) Rating/Material NEMA Type 1 plastic pluggable connectors NEMA Type 1 plastic pluggable connectors Warranty One-year limited warranty One-year limited warranty
12/24 VDC, Power Consumption: 70 mA min – 100 mA max
0.03 µV/graduation minimum
up to 200 conv. /sec. auto select Internal resolution: 1.5 million counts
Weight display resolution: 800,000 minimum Two inputs: 12/24 VDC
Two outputs:150 mA 48 VAC/ 150 mA 60 VDC
Opt isolated, 16-bit 0-20mA, 4-20mA (Maximum 350,000 ohm) 0-5VDC, 0-10VDC (Minimum 10,000 ohm)
Six-digit 0.51 in (13 mm), red LED Annunciators: Net, center of zero, stability
Five key, membrane panel, tactile feel Zero (Down), Tare (Up), Mode (Right), Print (Enter), C (On/Off)
Working Temperature: -15° C to 40° C Humidity: 85% non-condensing
4.17 in x 3.54 in x 2.28 in (106 mm x 90 mm x 58 mm)
APPROVALS
APPROVALS
SCT2200 with EtherNet/IP Fieldbus ModuleSCT1100-AN with Analog Output
12/24 VDC, Power Consumption: 70 mA min – 100 mA max
0.03 µV/graduation minimum
0.3 µV/graduation recommended One channel A/D 24-bit sigma-delta conversion,
up to 200 conv. /sec. auto select Internal resolution: 1.5 million counts
Weight display resolution: 800,000 minimum Two inputs: 12/24 VDC
Two outputs:150 mA 48 VAC/ 150 mA 60 VDC
Opt isolated, 16-bit 0-20mA, 4-20mA (Maximum 350,000 ohm) 0-5VDC, 0-10VDC (Minimum 10,000 ohm)
Six-digit 0.31 in (8 mm), red LED Annunciators: Net, center of zero, stability
Five key, tactile feel Zero (Down), Tare (Up), Mode (Right), Print (Enter), C (On/Off)
Working Temperature: -10° C to 50° C Humidity: 85% non-condensing
0.98 in x 4.52 in x 4.72 in (25 mm x 115 mm x 120 mm)
540
Standard Features
• Quick menu for real and theoretical calibration
• Red LED display (13 mm) and six LEDs show active functions
• Standard DIN rail-mounting with power supply and enclosures
• Configurable calibration and setup parameters from keyboard
• Up to three calibration linearization points or three from the keyboard
• Reading of the net, gross and tare weights, clearing, semi-automatic and presettable tare, scale switch, setting of outputs application thresholds
• Diagnostic information via serial port, message display, printing, setting of APW in counting mode, simulation of key pressure
An ISO 9001 Registered Company © 2019 Rice Lake Weighing Systems 01/19 Prices and specifications subject to change without notice. Visit ricelake.com for current prices.
Standard Features
• HUB Mode connects up to 16 transmitters to one fieldbus
• Quick menu for real and theoretical calibration
• Red LED display with six-digits (8 mm) and six LEDs show active functions
• Standard DIN rail mounting with power supply and enclosures
• Configurable calibration and setup parameters from keyboard
• Up to three calibration linearization points or three from the keyboard
• Reading of the net, gross and tare weights, clearing, semi-automatic and presettable tare, scale switch, setting of outputs application thresholds
• Diagnostic information via serial port, message display, printing, setting of APW in counting mode, simulation of key pressure, Modbus RTU
• Double RS-485 port for a quick network connection
• Printer management on second serial port available
• Multi-range function allows for subdividing the scale capacity in two, each up to 3,000 divisions
Page 2
SCT-3300
Signal Conditioning Transmitter/Indicator
SCT-3300 Specifications
Power
Excitation Voltage 10 VDC, 170 mA, 6 x 350 Ω Analog Signal Input Range 3.5 to 24 mV
Analog Signal Sensitivity
A/D Sample Rate 300 Hz
Resolution
Analog Output (if equipped)
Temperature & Humidity
Dimensions (W x H x D) 4.56 in x 3.72 in x 2.4 in (114 mm x 93 mm x 60 mm) Weight 0.5 lb (0.2 kg) Rating/Material DIN rail mount: NEMA Type 1 Warranty One-year limited warranty
Input: 20-28 VDC Power consumption: 8 W
0.1 µV/graduation minimum
1.0 µV/graduation recommended
Internal resolution: 16 million counts System linearity: ± 0.01% full scale
Optoisolated, 16 bit 0-20 mA, 4-20 mA (max 300 ohm) 0-10 VDC (min 10,000 ohm)
Working temperature: 14° F to 122° F (-10° C to 50° C) Humidity: 85% non-condensing
INDICATORS / CONTROLLERS
Standard Features
• Powers up to six (350 Ω) load cells in parallel (with a 24-bit A/D converter)
• A/D converter 24-bit (16,000,000 points)
• 12-bit analog output: 0-20 mA, 4-20 mA, 0-10 V
• Mounting on Omega/DIN rail for back panel or junction box
• IP67-rated enclosed versions
www.ricelake.com | Phone: 800-472-6703
An ISO 9001 Registered Company © 2019 Rice Lake Weighing Systems 01/19 Prices and specifications subject to change without notice. Visit ricelake.com for current prices.
541
Page 3
SCT-30 and SCT-40
Signal Conditioning Transmitter/Indicator
INDICATORS / CONTROLLERS
APPROVALS APPROVALS
Power
Excitation Voltage 5 VDC, 120 mA, 8 x 350 Ω 5 VDC, 240 mA, 16 x 350 Ω Analog Signal Input Range ± 39 mV ±39 mV
Analog Signal Sensitivity
A/D Sample Rate 300 Hz 600 Hz
Resolution
Digital Inputs/Outputs N/A 3 inputs 5-24 VDC, 5 outputs, 115 VAC/150 mA Serial Port RS-485 RS-485 or RS-232 simplex supports up to 115,200 bps
Analog Output (if equipped)
Display Eight-digit alphanumeric tow line LCD, 5 mm high
Keyboard Control knob and DIP switches
www.ricelake.com | Phone: 800-472-6703
Temperature & Humidity
Dimensions (W x H x D)
Weight 1 lb (0.5 kg) 1 lb (0.5 kg)
Rating/Material
Warranty One-year limited warranty One-year limited warranty
SCT converter with analog output
SCT-30 Specifications SCT-40 Specifications
Input: 12 -24 VDC Power consumption: 3W
0.1 µV/graduation minimum
1.0 µV/graduation recommended
Internal resolution: 16 million counts System linearity: ± 0.01% full scale
Optoisolated, 16 bit 0-20 mA, 4-20 mA (max 300 ohm) 0-10 VDC, 0-5 VDC (min 10,000 ohm)
Working temperature: -4° F to 140° F (-20° C to 60° C) Humidity: 85% non-condensing
SCT converter (W x H x D): 3.54 in x 3.74 in x 2.36 in (90 mm x 95 mm x 60 mm) IP67 enclosure (W x H x D): 6.69 in x 5.51 in x 3.74 in (170 mm x 140 mm x 95 mm)
DIN rail mount: NEMA Type 1 Sealed enclosure: NEMA Type 4/IP67, plastic enclosure, clear cover, six PG9 cord grips
Input: 12 -24 VDC Power consumption: 5W
0.1 µV/graduation minimum
1.0 µV/graduation recommended
Internal resolution: 16 million counts Weight display resolution: 999,999 System linearity: ± 0.01% full scale
Optoisolated, 16 bit 0-20 mA, 4-20 mA (max 300 ohm) 0-10 VDC, 0-5 VDC (min 10,000 ohm)
Backlit graphic LCD, transmissive 128 x 64 pixel resolution, 60 x 32 mm visible area
Five-key tactile keypad Test, Zero, Tare, Print Menu, Escape, Left and Up, Navigator, Enter
Working temperature: -4° F to 140° F (-20° C to 60° C) Humidity: 85% non-condensing
SCT converter (W x H x D): 5.82 in x 3.62 in x 2.36 in (148 mm x 92 mm x 60 mm)
DIN rail mount: NEMA Type 1 Sealed enclosure: NEMA Type 4/IP67, plastic enclosure, clear cover, six PG9 cord grips
542
Standard Features
• LCD display, 5 mm, eight-digit
• Powers up to eight (350 Ω) load cells in parallel (with a 24-bit A/D converter)
• A/D converter 24-bit (16,000,000 points) 4.8 kHz
• 16-bit analog output: 0-20 mA, 4-20 mA, 0-5 V, 0-10 V, ±5 V, and ±10 V
• Mounting on Omega/DIN rail for back panel or junction box
• IP67-rated enclosed versions
• Diagnostic message for load cell disconnect and over capacity errors
An ISO 9001 Registered Company © 2019 Rice Lake Weighing Systems 01/19 Prices and specifications subject to change without notice. Visit ricelake.com for current prices.
Standard Features
• LCD display, 60 mm x 32 mm
• Supports up to eight independent reading channels for load cells
• Displays weight, configuration, calibration and error conditions
• DIN rail mounting
• Theoretical calibration, real-weight calibration and error conditions
• Push button or preset tare
• Converts digital weight to analog output or optional DeviceNet™, Profibus™ or EtherNet/IP™ protocols
• Supports ASCII or MODBUS RTU protocols
• Full scale analog cut put with zero setting and PLC correction of analog signal
• Bit swapping selection for little endian and endian format
• Three digital inputs, five digital outputs
• One serial port, RS-232 simplex and RS-485 connection
• CD manual
Page 4
SCT-1100, 2200, 3300, SCT-10, 20, 30 and SCT 40
Signal Conditioning Transmitter/Indicator
SCT-1100
Part Number/Price
Part # Description
182588
Indicator, SCT1100-AN four load cell input with analog output
Est. Weight
1 lb Consult
Price
SCT-2200
Part Number/Price
Part # Description
Transmitters
182587 *
182589 Indicator, SCT2200-AN Analog Output 1 lb Consult
Fieldbus
182592 Fieldbus, SCT2200,Profinet Module 1 lb Consult 182594 Fieldbus, SCT2200, Wi-Fi Module 1 lb Consult 182593 Fieldbus, SCT2200, Profibus Module 1 lb Consult 182591 Fieldbus, SCT2200, EtherNet/IP Module 1 lb Consult 182596 Fieldbus, SCT2200, DeviceNet Module 1 lb Consult 182598 Fieldbus, SCT2200, EtherCAT Module 1 lb Consult 182597 Fieldbus, SCT2200, CANopen Module 1 lb Consult
188483
182599 Cable 1 lb Consult
*How to Order the SCT-2200 Order SCT-2200 transmitter. Order fieldbus module (HUB mode connects up to 16 transmitters to one fieldbus module). Order cables: (Number of SCTs — 1) + (1 for Fieldbus).
Indicator, SCT2200 for scale input to be used with fieldbus module
SCT converter RS 232/485 to EtherNet TCP/IP and Modbus TCP
Est. Weight
1 lb Consult
1 lb Consult
Price
SCT-3300
Part Number/Price
Part # Description
Transmitters
188725
Indicator, SCT-3300 four load cell input with analog output
Est. Weight
1 lb Consult
Price
Power Supply
Part Number/Price
Part # Description
88792 12 VDC 1.2 A DIN rail mounted power supply 1 lb Consult 119244 24 VDC 1.3
A DIN rail mounted power supply 1 lb Consult
Est. Weight
Price
SCT-10
Part Number/Price
Part # Description
129393 SCT-10 converter with analog output 1 lb Consult 129394 SCT-10 converter with analog output in enclosure 1 lb Consult 131129 Installation manual 1 lb Consult
Est. Weight
Price
SCT-20
Part Number/Price
Part # Description
129396 SCT-20 converter with analog output 1 lb Consult 129397 SCT-20 converter with DeviceNet 129558 SCT-20 converter with Profibus 129398 SCT-20 converter with EtherNet/IP 132534 SCT-20 converter with EtherNet TCP/IP 156903 SCT-20 converter with Modbus/TCP 1 lb Consult 131128 Installation manual 1 lb Consult
NTEP Approved
162883 SCT-20 converter with analog output Consult 162886 SCT-20 converter with EtherNet/IP Consult 162887 SCT-20 converter with EtherNet TCP/IP Consult
DP 1 lb Consult
Est. Weight
1 lb Consult
1 lb Consult 1 lb Consult
Price
SCT-30
Part Number/Price
Part # Description
156794 SCT-30 converter with analog output 1 lb Consult 156834 SCT-30 converter with analog output in enclosure 1 lb Consult 131129 Installation manual 1 lb Consult
Est. Weight
Price
SCT-40
Part Number/Price
Part # Description
170470 SCT-40 with analog output 1 lb Consult 170471 SCT-40 with DeviceNet 1 lb Consult 170472 SCT-40 with Profibus 1 lb Consult 170473 SCT-40 with EtherNet/IP 1 lb Consult 170474 SCT-40 with TCP/IP 1 lb Consult 170475 SCT-40 with Modbus/TCP 1 lb Consult 170476 SCT-40 with Profinet/I/O 1 lb Consult 131128 Installation manual 1 lb Consult
Est. Weight
Price
INDICATORS / CONTROLLERS
An ISO 9001 Registered Company © 2019 Rice Lake Weighing Systems 01/19 Prices and specifications subject to change without notice. Visit ricelake.com for current prices.
www.ricelake.com | Phone: 800-472-6703
543
Loading...