Rice Lake Weighing Systems SCT-1100, SCT-2200 Comparative Matrix

SCT Comparative Matrix
SCT-1100 Specifications SCT-2200 Specifications SCT-30 Specifications SCT-40 Specifications
Power
Analog Signal Sensitivity
A/D Sample Rate
Resolution
Digital Inputs/Outputs
Serial Port (1) RS-485, (1) RS-232 (1) RS-485, (1) RS-232 RS-485 RS-485 or RS-232 simplex supports up to 115,200 bps
Analog Output (if equipped)
Optional Supported Protocols
Display
Keyboard
Temperature & Humidity
Dimensions (W x H x D)
Weight 1 lb (0.5 kg) 1 lb (0.5 kg) 1 lb (0.5 kg) 1 lb (0.5 kg)
Rating/Material
Warranty One-year limited warranty One-year limited warranty One-year limited warranty One-year limited warranty
12/24 VDC Power Consumption: 70 mA min – 100 mA max
0.03 µV/graduation minimum
0.3 µV/graduation recommended Four channel A/D 24-bit sigma-delta conversion,
up to 200 conv. /sec. auto select Internal resolution: 1.5 million counts
Weight display resolution: 800,000 minimum
Two inputs: 12/24 VDC Two outputs:150 mA 48 VAC/ 150 mA 60 VDC
Opt isolated, 16-bit 0-20 mA, 4-20 mA (Maximum 350,000 ohm) 0-5 VDC, 0-10 VDC (Minimum 10,000 ohm)
Analog Output (Standard) Analog Output, Ethernet TCP/IP, EtherNet/IP
Six-digit (13 mm), red LED Annunciators: Net, center of zero, stability
Five key, membrane panel, tactile feel Zero (Down), Tare (Up), Mode (Right),
Print (Enter), C (On/Off) Working Temperature: 5° F to 104° F (-15° C to 40° C)
Humidity: 85% non-condensing
4.17 in x 3.54 in x 2.28 in (106 mm x 90 mm x 58 mm)
NEMA Type 1 plastic pluggable connectors NEMA Type 1 plastic pluggable connectors DIN rail mount: NEMA Type 1
12/24 VDC Power Consumption: 70 mA min – 100 mA max
0.03 µV/graduation minimum
0.3 µV/graduation recommended One channel A/D 24-bit sigma-delta conversion,
up to 200 conv. /sec. auto select Internal resolution: 1.5 million counts
Weight display resolution: 800,000 minimum
Two inputs: 12/24 VDC Two outputs:150 mA 48 VAC/ 150 mA 60 VDC
Opt isolated, 16-bit 0-20 mA, 4-20 mA (Maximum 350,000 ohm) 0-5 VDC, 0-10 VDC (Minimum 10,000 ohm)
DeviceNet™, Profibus® DP, Modbus/TCP, Profinet, EtherCAT, CANopen
Six-digit (8 mm), red LED Annunciators: Net, center of zero, stability
Five key, tactile feel Zero (Down), Tare (Up), Mode (Right),
Print (Enter), C (On/Off) Working Temperature: 5° F to 104° F (-15° C to 40° C)
Humidity: 85% non-condensing
0.98 in x 4.52 in x 4.72 in (25 mm x 115 mm x 120 mm)
,
Input: 12 -24 VDC Power consumption: 3 watts
0.1 µV/graduation minimum
1.0 µV/graduation recommended 300 Hz 600 Hz
Internal resolution: 16 million counts System linearity: ± 0.01% full scale
N/A 3 inputs 5-24 VDC, 5 outputs, 115 VAC/150 mA
Optoisolated, 16 bit 0-20 mA, 4-20 mA (max 300 ohm) 0-10 VDC, 0-5 VDC (min 10,000 ohm)
Analog Output (Standard) DeviceNet™, Profibus™, EtherNet/IP™, Analog Output,
Eight-digit alphanumeric tow line LCD, 5 mm high Backlit graphic LCD, transmissive
Control knob and DIP switches Five-key tactile keypad
Working temperature: -4° F to 140° F (-20° C to 60° C) Humidity: 85% non-condensing
SCT converter (W x H x D): 3.54 x 3.74 x 2.36 in (90 x 95 x 60 mm)
IP67 enclosure (W x H x D): 6.69 x 5.51 x 3.74 in (170 x 140 x 95 mm)
Sealed enclosure: NEMA Type 4/IP67, plastic enclosure, clear cover, six PG9 cord grips
Input: 12 -24 VDC Power consumption: 5W
0.1 µV/graduation minimum
1.0 µV/graduation recommended
Internal resolution: 16 million counts Weight display resolution: 999,999 System linearity: ± 0.01% full scale
Optoisolated, 16 bit 0-20 mA, 4-20 mA (max 300 ohm) 0-10 VDC, 0-5 VDC (min 10,000 ohm)
Ethernet TCP/IP, Modbus/TCP, Profinet I/O
128 x 64 pixel resolution, 60 x 32 mm visible area
Test, Zero, Tare, Print Menu, Escape, Left and Up, Navigator, Enter
Working temperature: -4° F to 140° F (-20° C to 60° C) Humidity: 85% non-condensing
SCT converter (W x H x D): 5.82 x 3.62 x 2.36 in (148 x 92 x 60 mm)
DIN rail mount: NEMA Type 1 Sealed enclosure: NEMA Type 4/IP67, plastic enclo-
sure, clear cover, six PG9 cord grips
For PLC systems that require weight data from a scale, Rice Lake’s compact SCT transmitters deliver equivalent signal-conditioning function without the cost or bulk of a full size weight indicator/controller.
Each Rice Lake SCT is DIN Rail mountable within a cabinet or control panel, where the scale’s load cell signal is converted to analog output, serial output, or a specific network protocol. Unlike many other signal transmitters, Rice Lake’s SCT features a 0.3 inch weight display. With annunciators for unit and weighing status, as well as push buttons for zero, tare
and setpoint entry, the SCT weight display simplifies scale setup, calibration and operation.
*The following references: DeviceNet™, Profibus®, EtherNet/IP™ ODVA, Modbus RTU
®
are the property of their respective trademark holders.
TEL: 715-234-9171 • FAX: 715-234-6967 •
230 W. Coleman St. • Rice Lake, WI 54868 • USA
An ISO 9001 registered company © 2018 Rice Lake Weighing Systems PN 174280 02/18
Specifications subject to change without notice.
www.ricelake.com