Rice Lake Weighing Systems 920i Data sheet

Page 1
-110
Target
Dribble Preact Near Zero
Consec. #
Total
200.0 Lb 75 0.0 10.0
23 1687 Lb 3468 Lb
Slow Dispense
Net
Scale #1
Scale #104/19/2011 1:12PM
ID #1
Setup Menu
Pre Sets Totals
ID #2
920i® FlexWeigh104
loss-in-Weight Dispensing controls
Dispensing Materials
Print, Tare, Weigh (2 Speed Dispense), Print, Hold
Use the following steps to dispense material from a scale.
1. Press the Start button on the unit. The system veries the E-Stop button is pulled out and a valid target weight has been entered. The system then:
• Increments the consecutive number by one
• Tares the scale to zero (net mode)
2. The system begins dispensing either of three speeds while a 920i displays real time sequence progress.
Those three dispensing speeds include:
• Single speed dispensing - The system turns on fast ll until the target weight/preact
weight is satised.
• Parallel speed dispensing - Turns on the fast ll and slow ll until the dribble weight
is satised. The system then turns off the fast ll and leaves the slow ll on until the target weight/preact weight is satised.
• Dual speed dispensing - Turns on the fast ll until the dribble weight is satised.
The system turns on the slow ll until the target weight/preact weight is satised.
3. If during the dispensing cycle the system determines that the material supply on the scale has run empty, the system will pause the automatic process and prompt for a resupply of material. The current dispensing process can resume from where it left off by pressing Start.
4. The system does the following when the target/preact is reached.
• Turns off the output based on the dispensing mode.
• Updates the subtotal weight and number of dispenses
• Updates the total and number of dispenses
• Turns on the Dispense Complete output.
5. The system delays for the Delay After Dispense time before it exits the sequence and ready for the next dispense.
104
Application:
The 920i FlexWeigh 104 is designed for applications where a preset target weight is repeatedly dispensed from removable vessels or containers that may become empty during the sequence of a dispense. When an empty supply is detected, the system will prompt for more supply. When pressing Start, the system automatically tares the scale, starts the loss-in-weight dispense from zero, and stops as programmed; all while transmitting and storing the accumulated weight totals.
Standard Features:
• Stainless Steel NEMA 4X enclosure
• Pre-programmed and congured 920i HMI Indicator/Controller
• Heavy-duty push buttons and switches
E-stop, Start, Reset/Resume
• Built-in safety interlocks prevent start
Dispense Screen
An ISO Registered Company © 2011 Rice Lake Weighing Systems PN 121116 5/11
without adequate weight to complete cycle
• (2) 2amp, 120 VAC feed output (fast and slow feed)
• Emergency stop which can be resumed at any point
• Auto Tare on START
• Auto Print and Weight Total
Options:
• Switches for manual-override control
• Large-diameter pilot lights
• 120 VAC outputs for: Dispense Complete and Slow Cycle
• Customized software and hardware congurations
230 West Coleman Street • Rice Lake, WI 54868 • USA
TEL: 715-234-9171 • FAX: 715-234-6967
www.ricelake.com
mobile: m.ricelake.com
Specications subject to change without notice.