Section 1 - Product and Company Identification
Rev:CD-0010
Product Name:
Lithium Manganese Dioxide Button Batteries(CR)
Company:
Camelion Battery Co. Ltd
Address:Unit 705, Cyber Timers Tower A, Tian’an Cyber Park,
Shenzhen,china
Sizes:
All
Date of preparation:
1. 1, 2018
Telephone:
(86) 0755-83618088
Fax:
(86)0755-83475720
Section 2 - Composition/Information on Ingredients
3
)
ACGIN TLV
(mg/m3)
Content
Ingredient CAS#
(wt%)
RTECS#
OSHA PEL
(mg/m
Lithium metal 7439-93-2 1~3 OJ5540000 - -
Manganese Dioxide 1313-13-9 14.5~33.5 OP0350000 5 5
Graphite 7782-42-5 0.6~1.5 MD9659600 - 2
Carbon Black 1333-86-4 0.9~2.2 FF5800000 3.5 3.5
Teflon 116-14-3 1.9~4.5 KX4025000 15 10
1,2-Dimethoxyethane 110-71-4 3.5~6.5 KI1451000 - 3(ppm)
Propylene Carbonate 108-32-7 1.2~1.9 FF9650000 - -
Lithium Perchlorate 7791-03-9 0.4~0.9 - - -
Section 3 - Hazards Summarizing
Routes of Entry: Inhalation: NO Skin: NO Ingestion: YES
Reports of Carcinogenicity: NTP: NO IARC: NO OSHA: NO
Health Hazards Acute and Chronic: These chemicals are in a sealed can. Risk of exposure occurs
only if the battery is mechanically or electrically abused. The
most likely risk is acute exp osure when a cell vents. PC is
mildly irritating on eye and skin contact. DME is believed to
be slightly to moderately irritant. Contact of electrolyte and
extruded lithium with skin and eyes should be avoided.
Effects of Overexposure: Irritation of skin or eyes. Lithium can cause thermal &
chemical burns upon contact with skin.
Rev:CD-0010
Section 4 - First-aid Measures
None unless internal materials exposure. If contents are leaked out, observe following
instructions
Inhalation Fumes can cause respiratory irritation. Remove to fresh air and consult a physician.
Skin Immediately flush skin with plenty of water. If itch or irritation by chemical burn
Persists, consult a physician.
Eyes Immediately flush eye with plenty of water for at least 15 minutes. Consult a
physician immediately.
Ingestion If swallowing a battery, consult a physician immediately.
If contents come into mouth, immediately rinse by plenty of water and consult a
physician.
Section 5 - Fire-fighting Measures
Extinguishing Media Extinguisher of alkaline metal fire is effective.
Plenty of cold water is also effective to cool the surrounding area and
control the spread fire. But hydrogen gas may be evolved by the
reaction of water and lithium and it can form an explosive mixture.
Therefore in the case that lots of lithium batteries are burning in a
confined space, use a smothering agent.
Fire fighting procedure Use self-contained breathing apparatus and full protective gear not to
inhale harmful gas.
Section 6 - Accidental Release Measures
Spill release Procedures: If cell vents or is punctured, ventilate area well. Wear eye and skin
protection. Respiratory protection may be necessary in confined spaces.
Absorb liquid with suitable material such as sand or clay. Transfer to
container for later disposal.
Neutralizing Agent: Not relevant.
Section 7- Handling and Storage