RIB,Relay In A Box,Functional Devices RIBX24 Series Data Sheet

CURRENT
SENSORS
of ARRA 2009
RELAY & AC CURRENT SWITCH COMBOS
RIBX24 Series
Enclosed 20 Amp Relay/AC Sensor Combinations, with 24 Vac/dc Coil
RIBX24BA, RIBX24BF+
RIBX24BV^
Made in USA
Meets
Buy American
Sensor Feedback
Current Sensor Status
24 Vac/dc
Comm
RIBX24SBA, RIBX24SBF+
Sensor Feedback
Current Sensor Status
24 Vac/dc
Comm
SPECIFICATIONS
Expected Relay Life:
Operating Temperature:
Humidity Range:
Operate Time:
Relay Status:
Dimensions:
Wire Length:
Approvals:
Housing Rating:
Gold Flash:
24 Vac/dc
Comm
Blu - N/C
Yel - Comm
Org - N/O
RIBX24SBV^
24 Vac/dc
Selectable Jumper Wire
OPEN AUTO
Org
Org
Comm
FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS
10 million cycles minimum mechanical
-30 to 140° F 5 to 95% (noncondensing) 20ms Red LED On = Activated
4.00˝ x 4.00˝ x 1.80˝ with .50˝ NPT Nipple 16˝, 600V Rated UL Listed, UL916, UL864, C-UL California State Fire Marshal UL Accepted for Use in Plenum, NEMA 1 No
0-10 Vdc
V
0-5 Vdc
V
Comm
Blu - N/C
Yel - Comm
Org - N/O
0-10 Vdc
V
0-5 Vdc
V
Comm
Selectable Jumper Wire
Org
Org
OPEN AUTO
Coil Current:
50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input:
24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc
RIBX24SBA
Sensor Contact: +
When current sensor status is o (open), leakage
<30 uA @ 30Vac/dc
When current sensor status is on (closed), voltage drop
< .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp
Sensor Feedback Output: ^
Voltage output is proportional to current sensor range.
Min. Input Impedance = 30K ohms
Accuracy +/– 1% full scale
Vripple < 10m Vac
RIBX24 SERIES SELECTION GUIDE
Model#
RIBX24BF .50-20 Amps
RIBX24BA .50-20 Amps
RIBX24BV 0-20 Amps
RIBX24SBF .50-20 Amps
RIBX24SB
RIBX24SBV 0-20 Amps
* = Internal current sensor monitors current through common contact of relay.
= FDI Certied for use with electronically commutated motorsECMS
Sensing
Range
ECMS
ECMS
ECMS
ECMS
A .50-20 Amps
Type * Threshold Sensor Output Resistive
Internal w/
contact
status
Internal w/
contact
status
Internal w/
voltage
output
Internal w/
contact
status
Internal w/
contact
status
Internal w/
voltage
output
Fixed,
.50 Amp
Adjustable
Analog
Fixed,
.50 Amp
Adjustable
Analog
Solid State Contact 30 Vac/dc, 0.4 Amp
Solid State Contact 30 Vac/dc, 0.4 Amp
0-5 Vdc
0-10 Vdc
Solid State Contact 30 Vac/dc, 0.4 Amp
Solid State Contact 30 Vac/dc, 0.4 Amp
0-5 Vdc
0-10 Vdc
Override
Switch
20 Amp No
20 Amp No
20 Amp No
20 Amp Yes
20 Amp Yes
20 Amp Yes
C
ontact Ratings Notes
20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac
20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C)
Not rated for Electronic Ballast
10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac
Normally Open or Normally
Closed selected by yellow jumper wire
071717